SMDR, CDR data captured by Advanced PBX Data Logger from Siemens Hipath-35xx (CSV,MMDDYY)


This data is being extracted with help of the "Advanced PBX Data Logger" software only. It may not applicable for other software titles.

DescriptionData typeColumn name
Call timedatetimeCALL_TIME
TrunkstringTRUNK
LinestringEXT
Ring durationdatetimeRING
Call durationdatetimeCALL_DURATION
Call duration (s)integerCALL_DURATION_S
PhonestringDIALED_PHONE
Flag 2stringFLAG2
Call typestringCALL_TYPE
DirectionstringDIRECTION

Connection parameters

This information is applicable for Siemens Hipath 3000, Siemens Hipath 3350, Siemens Hipath 3500 and Siemens Hipath 3750.

Default parameters for serial communication: 9600-8-N-1 with hardware flow control.

Configure your PBX using the programming software, like HiPath 3000 Manager.

Go to: System status – Call charges – Output format

Pinout and wiring

PC (9 pin) PBX (9 pin)
1 1
2 3
3 2
4 6
5 5
6 4
7 8
8 7
9 9