Set the following parameters on the machine

Select Port0
Connection Object0
Comp Communication Protocol0 (ASCII)
Baud Rate5 (9600)
Character0 (7 data bits)
Parity0 (None)
Stop Bit0 (1)
Response Monitoring Time60
Communication Type0
DC1 Code17
DC2 Code18
DC3 Code147
DC4 Code20
DR Signal Check0
Ending DC3 Code0
Invalid Data1
TRNAS Data Code0
End of Block1
TV Check0
Heading Output0
Reset in Slave Communication0
Recovery Time of Reset1
Data Overwrite1
Remote Operation1
Check Sum0
EIA Character Code (#)173
EIA Character Code (*)186
EIA Character Code (=)194
EIA Character Code ([)161
EIA Character Code (])162

Set the following parameters on the PC

Serial port tab

Machine nameBrother - TC-32 A
Serial portCOM2 (or any free COM port)
Baud9600
Data bits7
ParityNone
Stop bits1

Data flow control tab

Use DTRFalse
Use RTSFalse
Require DSRFalse
Require CTSFalse
Set RTSTrue
Set DTRTrue
Software flowcontrolNone
Xon char#11
Xoff char#12

Data exchange format tab

Format modeUniform
Format parametersProgram start: %%
Program end: %%
Line start:
Line end: #0D#0A
Skip lines: ;
Ignore characters: No characters for remove
Remove blank lines: Yes
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No

Null modem cable, without handshake
PC, 9pin, DB9M | CNC, 25pin, DB25
 

Null modem cable, with full handshake
PC, 9pin, DB25M | CNC, 25pin, DB25
 

Null modem cable, without handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
 

Null modem cable, with full handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
 

 

If you have successfully connected DNC Precision with any other controller not in this list, we would appreciate your sending us the details to add to the list.