DNC and CNC setting for Fanuc 15M

These settings are for the DNC Precision software only. They may not work with other software.

Set the following parameters on the machine

Set the 'PWE' parameter #8000 (Enable changing parameters) to ON (all bits = 1). After changing parameters below, change this value to OFF (all bits = 0).
#50011
#50022
#50033
#51105
#51112
#51129
#51204
#51212
#51229
#51304
#51312
#51329
#00101
#00211
#00221
#00231
If you want, you can change baud rate (#5112,#5122,#5132)
BaudParameter value
24008
24009
480010
960011
Set additional parameters #0000
NameValue
TVC0
CTV1
ISP0
NCR0
EIA0

Set the following parameters on the PC

Serial port tab

Machine nameFanuc 15M
Serial portCOM2 (or any free COM port)
Baud2400
Data bits7
ParityEven
Stop bits2

Data flow control tab

Use DTRFalse
Use RTSTrue
Require DSRFalse
Require CTSTrue
Set RTSFalse
Set DTRFalse
Software flowcontrolNone
Xon char#11
Xoff char#13

Data exchange format tab

Format modeUniform
Format parametersProgram start: %
Program end: %
Line start:
Line end: #0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No

Null modem cable, without handshake
PC, 9pin, DB9M | CNC, 25pin, DB25
 

Null modem cable, with full handshake
PC, 9pin, DB25M | CNC, 25pin, DB25
 

Null modem cable, without handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
 

Null modem cable, with full handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
 

 

If you have successfully connected DNC Precision with any other controller not in this list, we would appreciate your sending us the details to add to the list.

Note: We are not responsible and do not provide guarantee for any of these settings, that have been sent us by our customers.