DNC and CNC setting for Hinumerik 2000T
These settings for DNC Precision software only. It may not work with other software.
Set the following parameters on the machine
| 5010 | 0 |
| 5011 | 11000101 |
| 5012 | 0 |
| 5013 | 11000101 |
| RTS line | 1 |
|
Change following bits in the parameter #5016 only
|
If you want, you can change baud rate (#5011,#5013)
| Baud | Parameter value |
| 1200 | 11000100 |
| 2400 | 11000101 |
| 4800 | 11000110 |
| 9600 | 11000111 |
|
|
Set the following parameters on the PC
Serial port tab
| Machine name | Hinumerik 2000T |
| Serial port | COM2 (or any free COM port) |
| Baud | 2400 |
| Data bits | 7 |
| Parity | Even |
| Stop bits | 2 |
Data flow control tab
| Use DTR | False |
| Use RTS | True |
| Require DSR | False |
| Require CTS | True |
| Set RTS | False |
| Set DTR | False |
| Software flowcontrol | None |
| Xon char | #11 |
| Xoff char | #13 |
Data exchange format tab
| Format mode | Uniform |
| Format parameters | Program start:
Program end:
Line start:
Line end: #0D#0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No |
| Null modem cable, without handshake |
| PC, 9pin, DB9M |
CNC, 25pin, DB25 |
|
|
| Null modem cable, with full handshake |
| PC, 9pin, DB9M |
CNC, 25pin, DB25 |
|
|
| Null modem cable, without handshake |
| PC, 25pin, DB25M |
CNC, 25pin, DB25 |
|
|
| Null modem cable, with full handshake |
| PC, 9pin, DB25M |
CNC, 25pin, DB25 |
|
|
If you have successfully connected DNC Precision
with any other controller not in this list, we would appreciate
your sending us the
details to add to the list.
Note: We are not
responsible and do not provide guarantee for any of these