DNC and CNC setting for Mazak - T2
These settings for DNC Precision software only. It may not work with other software.
Set the following parameters on the machine
| A15 (RS-232) | 206 |
| A16 (parity) | 1 (None, but in a program configuration you should specify 7 data bits and Even parity) |
| A17 (baud rate) | 6 (4800) |
| A18 (mode) | 6 (read and punch) |
| A19 | 0 |
| A20 (punch code) | 1 (ISO) |
| A21 | 1 |
| A22 | 10 |
| A23 | 10 |
| A24 (TV check) | 0 |
| A30 | 3 |
| A31 | 109 |
| A31 | 70 |
|
Set the following parameters on the PC
Serial port tab
| Machine name | Mazak - T2 |
| Serial port | COM2 (or any free COM port) |
| Baud | 4800 |
| Data bits | 7 |
| Parity | Even |
| Stop bits | 1 |
Data flow control tab
| Use DTR | False |
| Use RTS | True |
| Require DSR | False |
| Require CTS | True |
| Set RTS | False |
| Set DTR | False |
| Software flowcontrol | Both |
| Xon char | #11 |
| Xoff char | #13 |
Data exchange format tab
| Format mode | Uniform |
| Format parameters | Program start:
Program end:
Line start:
Line end: #0D#0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No |
| Null modem cable, without handshake |
| PC, 9pin, DB9M |
CNC, 25pin, DB25 |
|
|
| Null modem cable, with full handshake |
| PC, 9pin, DB9M |
CNC, 25pin, DB25 |
|
|
| Null modem cable, without handshake |
| PC, 25pin, DB25M |
CNC, 25pin, DB25 |
|
|
| Null modem cable, with full handshake |
| PC, 9pin, DB25M |
CNC, 25pin, DB25 |
|
|
If you have successfully connected DNC Precision
with any other controller not in this list, we would appreciate
your sending us the
details to add to the list.
Note: We are not
responsible and do not provide guarantee for any of these
settings, that have been sent us by our customers.