The necessary machine configuration changes for Okuma Okuma 100 EL
Tape puncher interface
Parameter
Value
A1 (tape code)
ISO
A2 (detect code automatically)
No
A3 (tape TV check)
No
A4 (enter tape code in ISO)
LF
A5 (tape delimiting)
%
A6 (special code)
Alarm
A7 (operation file name)
Punch
A8 (tape feed)
Space feed
A9 (tape feed holes)
50
Tape interface (RS232 parameters)
Parameter
Value
B1 (baud rate)
4800
B2 (data bits)
8
B3 (parity)
None
B4 (stop bits)
1
B5 (ready time)
50
B6 (flow control)
RTS/CTS
B7 (RS timeout)
20
B8 (transfer timeout)
20
B9 (DC2/DC4)
No
B10 (DC3 when finished)
No
Read/Write
Parameter
Value
1 (device number)
CN0
2 (tape delimiting code)
Null
3 (stop bits)
1
4 (parity)
None
5 (baud rate)
4800
6 (flow control)
RTS/CTS
7
8 bit JIS
8 (ready time)
50
9 (data bits)
8
Set the following parameters on the PC for Okuma 100 EL
Serial port tab
Machine name
Okuma - Okuma 100-EL
Serial port
COM2 (or any free COM port)
Baud
4800
Data bits
7
Parity
Even
Stop bits
2
Data flow control tab
Use DTR
False
Use RTS
True
Require DSR
False
Require CTS
True
Set RTS
False
Set DTR
False
Software flowcontrol
None
Xon char
#11
Xoff char
#13
Data exchange format tab
Format mode
Uniform
Format parameters
Program start: % Program end: % Line start: Line end: #0D#0A Skip lines: Ignore characters: No characters for remove Remove blank lines: No Program name prefix: O Program starting characters in the file: No Program ending characters in the file: No
Go to the 'Edit/AUX mode', [F3] (PIP), [F2] (Punch), type file name, then [Return] or [Write]
Reading from the PC
Go to the 'Edit/AUX mode', [F3] (PIP), [F1] (Read), [Return] or [Write]
Configure computer for Okuma Okuma OSP 5000
Serial port tab
Machine name
Okuma - Okuma OSP 5000
Serial port
COM2 (or any free COM port)
Baud
4800
Data bits
7
Parity
Even
Stop bits
1
Data flow control tab
Use DTR
False
Use RTS
True
Require DSR
False
Require CTS
True
Set RTS
False
Set DTR
False
Software flowcontrol
Both
Xon char
#11
Xoff char
#13
Data exchange format tab
Format mode
Uniform
Format parameters
Program start: % Program end: % Line start: Line end: #0A Skip lines: Ignore characters: No characters for remove Remove blank lines: No Program name prefix: O Program starting characters in the file: No Program ending characters in the file: No
Go to the 'Edit/AUX mode', [F3] (PIP), [F2] (Punch), type file name, then [Return] or [Write]
Reading from the PC
Go to the 'Edit/AUX mode', [F3] (PIP), [F1] (Read), [Return] or [Write]
The COM port settings to connect with Okuma OSP 5000M
Serial port tab
Machine name
Okuma - Okuma OSP 5000M
Serial port
COM2 (or any free COM port)
Baud
4800
Data bits
7
Parity
Even
Stop bits
1
Data flow control tab
Use DTR
False
Use RTS
True
Require DSR
False
Require CTS
True
Set RTS
False
Set DTR
False
Software flowcontrol
Both
Xon char
#11
Xoff char
#13
Data exchange format tab
Format mode
Uniform
Format parameters
Program start: % Program end: % Line start: Line end: #0A Skip lines: Ignore characters: No characters for remove Remove blank lines: No Program name prefix: O Program starting characters in the file: No Program ending characters in the file: No
Set the following parameters on Okuma Okuma OSP 5020L
Optional Parameter Word
1 (no tape leader/trailer)
0
34 (time before alarm)
30
39 (baud rate)
4800
44 (punch device)
0
45 (input device)
0
46 (output device)
0
54 (read device)
1
57 (time before alarm)
90
Optional Parameter Bit #1 - 0000 1011
1.0 (Auto parity check: yes)
1
1.1 (ISO code: yes)
1
1.2 (Tape vertical check: no)
0
1.3 (Delimiter %)
1
1.4 (Verify at read: no)
0
1.5 (Special code read: no)
0
1.6 (Special code alarm: no)
0
1.7 (Special code ignored: no)
0
Optional Parameter Bit #12 - 1010 1010
12.0 (1 stop bit: yes)
0
12.1 (No ready sig.: none)
1
12.2 (Parity check: no)
0
12.3 (Even parity: 1 - even, 0 - odd)
1
12.4 (8 data bits: no)
0
12.5 (DC code: yes)
1
12.6 (DC code type 2: no)
0
12.7 (File name read: yes)
1
Input/output operations
Sending to the PC
Go to the 'Edit/AUX mode', [F3] (PIP), [F2] (Punch), type file name, then [Return] or [Write]
Reading from the PC
Go to the 'Edit/AUX mode', [F3] (PIP), [F1] (Read), [Return] or [Write]
Set the following parameters on the PC for Okuma OSP 5020L
Serial port tab
Machine name
Okuma - Okuma OSP 5020L
Serial port
COM2 (or any free COM port)
Baud
4800
Data bits
7
Parity
Even
Stop bits
1
Data flow control tab
Use DTR
False
Use RTS
True
Require DSR
False
Require CTS
True
Set RTS
False
Set DTR
False
Software flowcontrol
Both
Xon char
#11
Xoff char
#13
Data exchange format tab
Format mode
Uniform
Format parameters
Program start: % Program end: % Line start: Line end: #0A Skip lines: Ignore characters: No characters for remove Remove blank lines: No Program name prefix: O Program starting characters in the file: No Program ending characters in the file: No
Set the following parameters on Okuma Okuma OSP 7000
Optional Parameter Word
1 (no tape leader/trailer)
0
34 (time before alarm)
30
39 (baud rate)
4800
44 (punch device)
0
45 (input device)
0
46 (output device)
0
54 (read device)
1
57 (time before alarm)
90
Optional Parameter Bit #1 - 0000 1011
1.0 (Auto parity check: yes)
1
1.1 (ISO code: yes)
1
1.2 (Tape vertical check: no)
0
1.3 (Delimiter %)
1
1.4 (Verify at read: no)
0
1.5 (Special code read: no)
0
1.6 (Special code alarm: no)
0
1.7 (Special code ignored: no)
0
Optional Parameter Bit #12 for Lathe - 1010 1010
12.0 (1 stop bit: yes)
0
12.1 (No ready sig.: none)
1
12.2 (Parity check: no)
0
12.3 (Even parity: 1 - even, 0 - odd)
1
12.4 (8 data bits: no)
0
12.5 (DC code: yes)
1
12.6 (DC code type 2: no)
0
12.7 (File name read: yes)
1
Input/output operations
Sending to the PC
Go to the 'Edit/AUX mode', [F3] (PIP), [F2] (Punch), type file name, then [Return] or [Write]
Reading from the PC
Go to the 'Edit/AUX mode', [F3] (PIP), [F1] (Read), [Return] or [Write]
Set the following parameters on the PC for Okuma OSP 7000
Serial port tab
Machine name
Okuma - Okuma OSP 7000
Serial port
COM2 (or any free COM port)
Baud
4800
Data bits
7
Parity
Even
Stop bits
1
Data flow control tab
Use DTR
False
Use RTS
True
Require DSR
False
Require CTS
True
Set RTS
False
Set DTR
False
Software flowcontrol
Both
Xon char
#11
Xoff char
#13
Data exchange format tab
Format mode
Uniform
Format parameters
Program start: % Program end: % Line start: Line end: #0D#0A Skip lines: Ignore characters: No characters for remove Remove blank lines: No Program name prefix: O Program starting characters in the file: No Program ending characters in the file: No
Set the following parameters on Okuma Okuma OSP U100
Optional parameters
Parameter
Value
1 (tape code)
ISO
2 (detect code automatically)
1 (Yes)
3 (tape TV check)
0 (No)
4 (program end code)
1 (%)
5 (tape ready verify)
0 (No)
6 (special code)
0 (No alarm)
7 (ignore special code)
1 (Ignore)
8 (file name output)
0 (Output)
9 (EOR code)
0 (CR,LF)
10 (punch empty character)
0 (Null)
11 (read device number)
0 (CN0)
12 (punch device number)
0 (CN0)
10 (tape feed)
1
With help of the [PAGE DOWN] button go to tape interface (RS232 - CN0) parameters
Parameter
Value
1 (stop bits)
1
2 (parity check)
0
3 (parity)
1 (Even)
4 (8 bit JIS)
1 (Yes)
5 (DC2/DC4)
0 (No)
6 (file name read)
1 (Execute)
7 (CNC slave)
0 (No, master)
8 (baud rate)
9600
9 (busy timeout)
15
Set the following parameters on the PC for Okuma OSP U100
Serial port tab
Machine name
Okuma - Okuma OSP-U100
Serial port
COM2 (or any free COM port)
Baud
9600
Data bits
7
Parity
Even
Stop bits
2
Data flow control tab
Use DTR
False
Use RTS
True
Require DSR
False
Require CTS
True
Set RTS
False
Set DTR
False
Software flowcontrol
None
Xon char
#11
Xoff char
#13
Data exchange format tab
Format mode
Uniform
Format parameters
Program start: % Program end: % Line start: Line end: #0D#0A Skip lines: Ignore characters: No characters for remove Remove blank lines: No Program name prefix: O Program starting characters in the file: No Program ending characters in the file: No
Communication parameters in the program to connect with Okuma T
Serial port tab
Machine name
Okuma - Okuma T
Serial port
COM2 (or any free COM port)
Baud
4800
Data bits
7
Parity
Even
Stop bits
2
Data flow control tab
Use DTR
False
Use RTS
True
Require DSR
False
Require CTS
True
Set RTS
False
Set DTR
False
Software flowcontrol
None
Xon char
#11
Xoff char
#13
Data exchange format tab
Format mode
Uniform
Format parameters
Program start: % Program end: % Line start: Line end: #0D#0A Skip lines: Ignore characters: No characters for remove Remove blank lines: No Program name prefix: O Program starting characters in the file: No Program ending characters in the file: No