DNC and CNC setting for Okuma - Okuma OSP 7000


These settings for DNC Precision software only. It may not work with other software.

Set the following parameters on the machine

1 (no tape leader/trailer)0
34 (time before alarm)10
39 (baud rate)4800
44 (punch device)0
45 (input device)0
46 (output device)0
54 (read device)1
57 (time before alarm)90
Optional parameter bits #1 (ISO code)0000 1011
Optional parameter bits #81010 1010
Optional parameter bits #12 (stop bits, parity)1010 0010
Input/output operations
Sending to the PCGo to the 'Edit mode' [F3] (PIP), [F2] (Punch), type file name, then [Return]
Reading from the PCGo to the 'Edit mode' [F3] (PIP), [F1] (Read), [Return]

Set the following parameters on the PC

Serial port tab

Machine nameOkuma - Okuma OSP 7000
Serial portCOM2 (or any free COM port)
Baud4800
Data bits7
ParityEven
Stop bits1

Data flow control tab

Use DTRFalse
Use RTSTrue
Require DSRFalse
Require CTSTrue
Set RTSFalse
Set DTRFalse
Software flowcontrolBoth
Xon char#11
Xoff char#13

Data exchange format tab

Format modeUniform
Format parametersProgram start: %
Program end: %
Line start:
Line end: #0D#0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No

Null modem cable, without handshake
PC, 9pin, DB9M CNC, 25pin, DB25
PC DB9 - CNC DB25
Null modem cable, with full handshake
PC, 9pin, DB9M CNC, 25pin, DB25
PC DB9 - CNC DB25
Null modem cable, without handshake
PC, 25pin, DB25M CNC, 25pin, DB25
PC DB25 - CNC DB25
Null modem cable, with full handshake
PC, 9pin, DB25M CNC, 25pin, DB25
PC DB25 - CNC DB25

 

If you have successfully connected DNC Precision with any other controller not in this list, we would appreciate your sending us the details to add to the list.

Note: We are not responsible and do not provide guarantee for any of these settings, that have been sent us by our customers.