6006 - Device type: 7 (unspecified terminal/printer)
6007 - Character set: 0 (no conversion)
6009 - IOU (except CPU-D4) Baud rate: 10 (2400 Baud)
6009 - IOU (CPU-D4) Baud rate: 10 (2400 Baud)
6009 - SMU (except CPU-D4) Baud rate: 8 (1200 Baud)
6009 - SMU (CPU-D4) Baud rate: 10 (2400 Baud)
6011 - Autoselect allowed: Yes (optional)
6017 - Mode selection for serial interface - should be RS-232
6101 - Set year month day to : YYMMDD
6102 - Set day of week: 1 - Sunday, 7 - Saturday
6103 - Set hour minute second: HHMMSS
6104 - 12h mode, display - Set it to N for 24 mode
6201 - Log internal calls? - Yes
6202 - Log incoming calls? - Yes
6203 - Block log output? - Yes
6204 - Digits to log - Set it to NO
6205 - Bar outgoing calls for guest - Yes if you want to stop guest making calls while the pbx memory is full. Usefull for hotels. (optional)
6301 - Log outgoing calls? - Yes
6302 - Log duration time - Set it to 0 because you can configure it in the application.
6303 - Log minimum meter pulses - Should set it to 0
6304 - Bar outgoing calls? - Yes if you want to stop the outgoing calls while the calls storage if out of order and the pbx memory is full. (optional)
6305 - Dialed number: suppress - Set it to 0 unless you want to strip the last n digits from the dialed number for security reasons.
6306 - Log dialed numbers beginning with 0 - Yes.
6307 - Log dialed numbers beginning with 1 - Yes.
6308 - Log dialed numbers beginning with 2 - Yes.
6309 - Log dialed numbers beginning with 3 - Yes.
6310 - Log dialed numbers beginning with 4 - Yes.
6311 - Log dialed numbers beginning with 5 - Yes.
6312 - Log dialed numbers beginning with 6 - Yes.
6313 - Log dialed numbers beginning with 7 - Yes.
6314 - Log dialed numbers beginning with 8 - Yes.
6315 - Log dialed numbers beginning with 9 - Yes.
6332 - Log minimum cost - Set it 0
6403 - Format table - Format 00-29, Set it to 01 and select Ericsson MD110 in app.
6404 - Lines per page - Set it to 0
6402 - Automatic I/O activation - Set it to 1 minute. (0 means disabled)
6701 - I/O Port - Value ppiii where pp is board position and iii is individual number of a V24 (IO unit) port.
6702 - Lines/page - Set it to 0

Data items

DescriptionData typeColumn name
Call timedatetimeCALL_TIME
Call duration (s)integerCALL_DURATION_S
Call typestringCALL_TYPE
DirectionstringDIRECTION
COstringTRUNK
ExtstringEXT
PhonestringDIALED_PHONE
RingdatetimeRING

Note: Products and companies mentioned here are used only for definition and identification purposes and can be trademarks and/or registered trademarks of the respective companies.