Siemens iSDX Realitis. SMDR/CDR data format and connection settings


This data is being extracted with help of the "Advanced PBX Data Logger" software only. It may not applicable for other software titles.

ISDX / Realitis by Siemens (Plessey)

Our software cannot translate HEX output from this PBX. So this system should be configured to the "Text" format if you wish to use our Advanced PBX Data Logger. When this phone system will be is set to the "Text" format then our software will capture outgoing calls.

To change the SMDR output format from HEX to the "Text" format:

LSSP: lists the system parameters.
SPCIT: is the system parameter will need changing.

If it is set to 0 then PBX outputs HEX, if set to 1 it outputs Text.

Data items

DescriptionData typeColumn name
Call timedatetimeCALL_TIME
Call durationdatetimeCALL_DURATION
Call duration (s)integerCALL_DURATION_S
Flag 1stringFLAG1
Dialed numberstringDIALED_PHONE
Call typestringCALL_TYPE
Access codestringACC
Call typestringDIRECTION
COstringTRUNK
ExtstringEXT

Note: Products and companies mentioned here are used only for definition and identification purposes and can be trademarks and/or registered trademarks of the respective companies.