Omega (CN7200,CN7500,CN7600,CN7800) data logger. MODBUS registers map.
This data is being extracted with the help of the Advanced Serial Data Logger (MODBUS RTU,ASCII) or Advanced TCP/IP Data Logger (MODBUS TCP) software only. It may not applicable for other software titles.
MODBUS offset | Description | Units | Data type |
4095 | Process value (pv) | | word |
4096 | Set point (sv) | | word |
4097 | Upper limit of temperature range | | word |
4098 | Lower limit of temperature range | | word |
4099 | Input temperature sensor type | | word |
4100 | Control method | | word |
4101 | Heating/cooling control selection | | word |
4102 | 1st group of heatlng/cooling control cycle | | word |
4103 | 2nd group of heating/cooling control cycle | | word |
4104 | Pb proportional band | | word |
4105 | Ti integral time | | word |
4106 | Td derivative time | | word |
4107 | Integration default | | word |
4108 | Proportional control offset error value, when ti = 0 | | word |
4109 | The setting of coef when dual loop output control are used | | word |
4110 | The setting of dead band when dual loop output control are used | | word |
4111 | Hysteresis setting value of the 1st output group | | word |
4112 | Hysteresis setting value of the 2nd output group | | word |
4113 | Output value read and write of output 1 | | word |
4114 | Output value read and write of output 2 | | word |
4115 | Upper limit regulation of analog linear output | | word |
4116 | Lower limit regulation of analog linear output | | word |
4117 | Temperature regulation value | | word |
4118 | Analog decimal setting | | word |
4123 | Pid parameter selection | | word |
4124 | Sv value corresponded to pid value | | word |
4127 | Alarm 1 type | | word |
4128 | Alarm 2 type | | word |
4129 | Alarm 3 type | | word |
4130 | System alarm setting | | word |
4131 | Upper limit alarm 1 | | word |
4132 | Lower limit alarm 1 | | word |
4133 | Upper limit alarm 2 | | word |
4134 | Lower limit alarm 2 | | word |
4135 | Upper limit alarm 3 | | word |
4136 | Lower limit alarm 3 | | word |
4137 | Read led status | | word |
4138 | Read pushbutton status | | word |
4139 | Setting lock status | | word |
4142 | Software version | | word |
4143 | Start pattern number | | word |
4159 | Actual step number setting inside the correspond pattern | | word |
4175 | Cycle number for repeating the execution of the correspond pattern | | word |
4191 | Link pattern number setting of the correspond pattern | | word |