Advanced OPC Data Logger for OPC DA and OPC UA
For Windows 7 - Windows 11 (incl. Server, x86 and x64)Windows 11, 10, 8.1, 8, 7, Vista, XP, 2000
Windows Server 2025, 2022, 2019, 2016, 2012 R2, 2012, 2008 R2, 2008, 2003
x86, x64. Latest version: 4.1.9 build 1104. November 4, 2026.
OPC collection and export features
Multiple OPC servers. Collects tags from several local or remote servers in one configuration. Use separate configurations when groups of servers need different processing or export settings.
OPC Classic and OPC UA. Supports OPC DA 1 and 2 in every edition. OPC HDA, OPC AE, OPC XML and OPC UA are available by edition.
Tag selection and connection recovery. Browses server tags and can automatically reconnect after a connection drops.
Change-based or scheduled logging. Records changes as the server reports them, or exports group values at a fixed interval or on a schedule.
Timestamps and quality. Exports tag timestamps in local time or UTC. Include tag name and quality in per-tag records, or filter the group to export only good values.
Grouped records and filters. Writes individual tag records or exports the tags in a group together. Enterprise adds filter plugins for calculations, deadband and aggregation.
CSV and Excel. Creates CSV logs in every edition. Professional and Enterprise add export plugins for direct Excel output and other file formats.
SQL and ODBC export. Uses export plugins to write to supported databases, including SQL Server, MySQL and PostgreSQL.
Windows service. Starts logging without a user signed in on Standard, Professional and Enterprise. Program messages help diagnose server and export errors.
Connect to a local or remote OPC server

For a local OPC DA server, choose the server from the configuration dialog and browse its tags. A remote OPC DA connection requires DCOM configuration on the client and server computers. Use the OPC and DCOM setup guide and the remote connection error guide if the local connection works and the remote one fails.
With OPC UA in Enterprise, connect to the server's binary opc.tcp:// endpoint to collect live data. Check the server's connection settings before adding tags. To try the setup without a plant connection, OPC Server Simulator can provide sample DA or UA tags.
Choose what each row records
For a history of changes, export one row per tag update. Include the tag name, value and timestamp, and add quality when it matters for troubleshooting. If several servers use the same tag names, include the server name so you can tell the records apart.
For a periodic production report, group the tags you want side by side and enable export at a fixed interval. For example, log line speed, the current batch ID and a production counter once per minute. The OPC aggregation tutorial shows how to combine tag values into a record.
Send OPC data to CSV, Excel or a SQL database
Start with CSV logging for Excel when you need a file you can open and inspect. Enable the group timestamp option if each row needs a date and time column.
For a queryable history, configure a database export plugin and map each tag field to the table. The OPC to SQL guide walks through the choices for SQL Server, MySQL and other databases. If your application needs a table that always holds the latest value for each tag, see Datatag Link's live OPC-to-SQL connection.
Run logging as a Windows service
First verify that the logger receives updates and writes records in the desktop application. Then configure service mode for routine collection. Give the service account access to the OPC server and to the log directory or database. Start the service and check that new records appear after you sign out. See the user manual for the service settings.Choose the edition for your OPC interface and output
- Lite reads OPC DA and records CSV with one configuration.
- Standard adds OPC HDA and Windows service mode.
- Professional adds OPC AE, database and Excel export plugins, and a second configuration.
- Enterprise adds live OPC UA and OPC XML, filter plugins and support for more than two configurations.
A single configuration can collect tags from multiple servers. Check the edition comparison for protocol and plugin details, use the free trial with your server, and find current pricing on the order page.
Recent updates
[October 30, 2026] AGG Software has released an update for Advanced OPC Data Logger, bringing it to version 4.1.8 build 1030. The previous version didn't export tag names with spaces to CSV or XML files in the configuration.[October 26, 2026] The Advanced OPC Data Logger software has been slightly modified to version 4.1.8 build 1026. - OPC DA, AE, HDA, UA and XML clients: opening a data source takes about 0.15 seconds. Before, it took 1-3 seconds, because the plugin read the list of all OPC servers of the computer every time. - OPC UA client: no unneeded network name lookup before each connection to a server given by its IP address (it could add up to several seconds to every connection).
See the full changelog for earlier releases.
Frequently asked questions
Which edition do I need for OPC UA?
Enterprise reads live OPC UA values over binary opc.tcp:// endpoints. Its UA client is for live data access. For classic historical data access, check the OPC HDA row in the edition comparison.
Can I log tags from several OPC servers at once?
Yes. All editions can collect tags from several servers in one configuration. The edition determines how many independent configurations you can create.
Can I log a value every minute even when it stays the same?
Yes. In the group settings, enable Export at fixed interval and set the interval you need. Check the resulting rows to confirm that the timing and tag values match your reporting needs.
Can I include OPC quality and timestamps in the output?
Yes. You can export the tag update time and, when exporting individual tags, the item name and quality. You can also filter exports to include only values marked as good.
Can I connect to a remote OPC DA server?
Yes. Configure DCOM on both computers and verify that the Windows account running the logger can connect to the remote server. If you run the logger as a service, test with its service account.