Schneider Electric (Sepam 60) logging. MODBUS registers map.


This data is being extracted with the help of the Advanced Serial Data Logger (MODBUS RTU,ASCII) or Advanced TCP/IP Data Logger (MODBUS TCP) software only. It may not applicable for other software titles.

MODBUS offsetDescriptionUnitsData type
512Phase current I1 dword
514Phase current I2 dword
516Phase current I3 dword
518Residual current i0 dword
520Residual current i0 dword
522Demand current IM1 dword
524Demand current IM2 dword
526Demand current IM3 dword
528Peak demand current IM1 dword
530Peak demand current IM2 dword
532Peak demand current IM3 dword
534Phase-to-phase voltage U21 dword
536Phase-to-phase voltage U32 dword
538Phase-to-phase voltage U13 dword
540Phase-to-neutral voltage V1 dword
542Phase-to-neutral voltage V2 dword
544Phase-to-neutral voltage V3 dword
546Residual voltage v0 dword
548Positive sequence voltage vd dword
550Negative-sequence voltage vi dword
552Frequency fHzdword
554Active power PkWinteger
560Power factor cos integer
562Peak demand active power PMkWinteger
564Peak demand reactive power QMkvarinteger
566Active power P phase 1kWinteger
568Active power P phase 2kWinteger
570Active power P phase 3kWinteger
572Reactive power Q phase 1kvarinteger
574Reactive power Q phase 2kvarinteger
576Reactive power Q phase 3kvarinteger
578Apparent power S phase 1kVAinteger
580Apparent power S phase 2kVAinteger
582Apparent power S phase 3kVAinteger
584Positive active energy ea+kWdword
586Negative active energy ea-kWdword
588Positive reactive energy er+kvardword
590Negative reactive energy er-kvardword
592Ext. positive active energy ea+kWdword
594Ext. negative active energy ea-kWdword
596Ext. positive reactive energy er+kvardword
598Ext. negative reactive energy er-kvardword
600Neutral-point voltage vnt dword
616Number of operations dword
618Tripping current phase 1 itrip1 dword
620Tripping current phase 2 itrip2 dword
622Tripping current phase 3 itrip3 dword
624Tripping current calculated i0 itrip0 dword
636Number of operations dword
650Impedance ZdMOhmdword
652Impedance Z21MOhmdword
654Impedance Z32MOhmdword
656Impedance Z13MOhmdword
678Voltage difference dU (synchro-check) dword
680Frequency difference df (synchro-check)Hzdword
682Phase difference dPhi (synchro-check) dword
684Capacitor capacitance C1 (or c21) dword
686Capacitor capacitance C2 (or c32) dword
688Capacitor capacitance C3 (or c13) dword
768Temperature 1 MET148-2 nD 1Csmallint
769Temperature 2 MET148-2 nD 1Csmallint
770Temperature 3 MET148-2 nD 1Csmallint
771Temperature 4 MET148-2 nD 1Csmallint
772Temperature 5 MET148-2 nD 1Csmallint
773Temperature 6 MET148-2 nD 1Csmallint
774Temperature 7 MET148-2 nD 1Csmallint
775Temperature 8 MET148-2 nD 1Csmallint
776Temperature 1 MET148-2 nD 2Csmallint
777Temperature 2 MET148-2 nD 2Csmallint
778Temperature 3 MET148-2 nD 2Csmallint
779Temperature 4 MET148-2 nD 2Csmallint
780Temperature 5 MET148-2 nD 2Csmallint
781Temperature 6 MET148-2 nD 2Csmallint
782Temperature 7 MET148-2 nD 2Csmallint
783Temperature 8 MET148-2 nD 2Csmallint
784Total harmonic distortion uthd word
785Total harmonic distortion ithd word
786Angle 0 word
788Angle 0 word
790Angle 1 word
791Angle 2 word
795Machine rotation speed word
796Thermal capacity used word
797Running hours counter word
798Time before tripping word
799Time before closing word
800Starting time / overload word
801Start inhibit time word
802Number of starts allowed word
803Learnt cooling time constant T2 (49 RMS) thermal rate 1 word
804Learnt cooling time constant T2 (49 RMS) thermal rate 2 word
805Total cumulative breaking current word
806Cumulative breaking current (0 in - 2 in) word
807Cum. breaking current (2 in - 5 in) word
808Cum. breaking current (5 in - 10 in) word
809Cum. breaking current (10 in - 40 in) word
810Cumulative breaking current (40 in - ) word
811Initial value of cumulative breaking current word
812Starting/overload current word
813Operating time word
There are more MODBUS items for this device. Please, download the program.


Schneider Electric (EM1000,EM1100,EM1200) data logging
Schneider Electric (EM3502,EM3550) data logging
Schneider Electric (EM4200) data logging
Schneider Electric (EM6400) data logging
Schneider Electric (EM6400NG,PM2100,PM2200) data logging
Schneider Electric (EM7200) data logging
Schneider Electric (EMB,EME) data logging
Schneider Electric (iEM3000) data logging
Schneider Electric (PM600) data logging
Schneider Electric (PM8000) data logging
Schneider Electric (PVSCL20E) data logging
Schneider Electric (Sepam 60) data logging
Schneider Electric (Sepam 80) data logging
Schneider Electric (Symmetra PX) data logging
Schneider Electric PM1000 PM1200 data logging
Schneider Electric PM9C data logging
Schneider Electric PowerLogic ION6200 data logging
Schneider Electric PowerLogic ION7300 data logging
Schneider Electric PowerLogic ION7500-ION7600 data logging
Schneider Electric PowerLogic ION7550-ION7650 data logging
Schneider Electric PowerLogic ION8300-ION8400-ION8500 data logging
Schneider Electric PowerLogic ION8600 data logging
Schneider Electric PowerLogic ION8800 data logging

Note: Products and companies mentioned here are used only for definition and identification purposes and can be trademarks and/or registered trademarks of the respective companies.