Configure the settings on Citizen Cincom
| Put control in EDIT mode. Press [LIST] [I/O] [232C Set] softkeys. Input/Output Destination is 'IC CARD R/W'. Change the following parameters: | |
| Baud rate | 9600 |
| Stop Bit | 2 Bit |
| Parity baud rate | Even |
| Char Length | 7 |
| HRDWRE Flow | Invalid |
| XON/XOFF | Valid |
| DC Code Out | Output (DC3 output) |
| TV Check | OFF |
| EOB Output | CR LF |
| Feed No. (1/10 second) | 10 |
| Time-Out (1/10 second, 100 = 10 seconds) | 100 |
| Data Code | ISO |
| DC3 Code | 0x93 |
The COM port settings to connect with Cincom
Serial port tab| Machine name | Citizen - Cincom |
| Serial port | COM2 (or any free COM port) |
| Baud | 9600 |
| Data bits | 7 |
| Parity | Even |
| Stop bits | 2 |
| Use DTR | False |
| Use RTS | False |
| Require DSR | False |
| Require CTS | False |
| Set RTS | True |
| Set DTR | True |
| Software flowcontrol | Both |
| Xon char | #11 |
| Xoff char | #13 |
| Format mode | Uniform |
| Format parameters | Program start: %% Program end: %% Line start: Line end: #0D#0A Skip lines: ; Ignore characters: No characters for remove Remove blank lines: No Program name prefix: O Program starting characters in the file: No Program ending characters in the file: No |
Null modem cable, without handshake
PC, 9pin, DB9M | CNC, 25pin, DB25
Null modem cable, with full handshake
PC, 9pin, DB25M | CNC, 25pin, DB25
Null modem cable, without handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
Null modem cable, with full handshake
PC, 25pin, DB25M | CNC, 25pin, DB25