Check the special protocols option in 'DSPY 80-CONFIGURE'
COMMUNICATION ENHANCEMENT OPTION
ON
Permanently set all communication parameters in 'SD50-SERIAL DEFN'
PROTCL
2 (XON/XOFF)
PGM TYPE
1 = (Standard Burny 3 word address program)
CHAR TYPE
CHAR TYPE-3 = EP7D-ASCII, EVEN PARITY, 7 DATA BITS
BAUD RATE
2400
Set the following parameters on the PC
Serial port tab
Machine name
Burny 1400
Serial port
COM2 (or any free COM port)
Baud
2400
Data bits
7
Parity
Even
Stop bits
1
Data flow control tab
Use DTR
False
Use RTS
False
Require DSR
False
Require CTS
True
Set RTS
True
Set DTR
False
Software flowcontrol
Both
Xon char
#11
Xoff char
#13
Data exchange format tab
Format mode
Uniform
Format parameters
Program start: %% Program end: EOF:000 Line start: Line end: #0A Skip lines: Ignore characters: No characters for remove Remove blank lines: No Program name prefix: P Program starting characters in the file: No Program ending characters in the file: No
Permanently set all communication parameters in 'SD50-SERIAL DEFN'
PROTOCOL
PROTCL-6 = CLINK 1
PROGRAM TYPE
PGM TYPE-1 = WADR
CHARACTER TYPE
CHAR TYPE-3 = EP7D-ASCII, EVEN PARITY, 7 DATA BITS
BAUD RATE
BAUD RATE-7 = 9600
Set the following parameters on the PC
Serial port tab
Machine name
Burny 2.5 CLINK
Serial port
COM2 (or any free COM port)
Baud
9600
Data bits
7
Parity
Even
Stop bits
1
Data flow control tab
Use DTR
False
Use RTS
False
Require DSR
False
Require CTS
False
Set RTS
False
Set DTR
False
Software flowcontrol
Both
Xon char
#11
Xoff char
#13
Data exchange format tab
Format mode
Data reception
Format parameters
Program start: #0D#0A%%#0D#0A Program end: #1A#0D#0A Line start: Line end: #0D#0A Skip lines: Ignore characters: No characters for remove Remove blank lines: No Program name prefix: P Program starting characters in the file: No Program ending characters in the file: No
Check the special protocols option in 'DSPY 80-CONFIGURE'
COMMUNICATION ENHANCEMENT OPTION
OFF
Permanently set all communication parameters in 'SD50-SERIAL DEFN' (see the 'INSTALL' section in your machine user manual)
PROTCL
2 (XON/XOFF)
PGM TYPE
1 = (Standard Burny 3 word address program)
CHAR TYPE
5 (OP7D-ASCII, Odd parity, 7 data bits)
BAUD RATE
2400
Set the following parameters on the PC
Serial port tab
Machine name
Burny 3
Serial port
COM2 (or any free COM port)
Baud
2400
Data bits
7
Parity
Odd
Stop bits
1
Data flow control tab
Use DTR
False
Use RTS
False
Require DSR
False
Require CTS
False
Set RTS
True
Set DTR
True
Software flowcontrol
Both
Xon char
#14
Xoff char
#12
Data exchange format tab
Format mode
Uniform
Format parameters
Program start: %% Program end: %% Line start: Line end: #0D#0A Skip lines: Ignore characters: No characters for remove Remove blank lines: Yes Program name prefix: O Program starting characters in the file: No Program ending characters in the file: No