DNC and CNC setting for Mitsubishi - Meldas 60 Series

These settings are for the DNC Precision software only. They may not work with other software.

Set the following parameters on the machine

Use different devices for input and output, but with same port number
IO parameters screen 1/6
9001 (In port #)2
9002 (In device #)1
9003 (Out port #)2
9004 (Out device #)0
9005 (Tape mode)2
IO parameters
9101,9201IN,OUT
9102,9202 (baud rate)2 (4800)
9103,9203 (stop bits)1 (one stop bit)
9104,9204 (add parity)1 (Yes)
9105,9205 (parity)1 (Even)
9106,9206 (data bits)2 (7 data bits)
9108,9208 (use DC codes)3 (yes, DC1 and DC3)
9109,9209 (no parity for DC codes)1 (Yes)
9112,9212 (CR output)1 (Yes)
9113,9213 (EIA output)0 (No)
9114,9214 (Feed chr.)0 (No)

Set the following parameters on the PC

Serial port tab

Machine nameMitsubishi - Meldas 60 Series
Serial portCOM2 (or any free COM port)
Baud4800
Data bits7
ParityEven
Stop bits1

Data flow control tab

Use DTRFalse
Use RTSTrue
Require DSRFalse
Require CTSTrue
Set RTSFalse
Set DTRFalse
Software flowcontrolBoth
Xon char#11
Xoff char#13

Data exchange format tab

Format modeUniform
Format parametersProgram start: %%
Program end: %%
Line start:
Line end: #0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No

Null modem cable, without handshake
PC, 9pin, DB9M | CNC, 25pin, DB25
 

Null modem cable, with full handshake
PC, 9pin, DB25M | CNC, 25pin, DB25
 

Null modem cable, without handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
 

Null modem cable, with full handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
 

 

If you have successfully connected DNC Precision with any other controller not in this list, we would appreciate your sending us the details to add to the list.

Note: We are not responsible and do not provide guarantee for any of these settings, that have been sent us by our customers.