DNC and CNC setting for Okuma - Okuma 100-EL
These settings are for the DNC Precision software only. They may not work with other software.
Set the following parameters on the machine
Tape puncher interface |
Parameter | Value |
A1 (tape code) | ISO |
A2 (detect code automatically) | No |
A3 (tape TV check) | No |
A4 (enter tape code in ISO) | LF |
A5 (tape delimiting) | % |
A6 (special code) | Alarm |
A7 (operation file name) | Punch |
A8 (tape feed) | Space feed |
A9 (tape feed holes) | 50 |
Tape interface (RS232 parameters) |
Parameter | Value |
B1 (baud rate) | 4800 |
B2 (data bits) | 8 |
B3 (parity) | None |
B4 (stop bits) | 1 |
B5 (ready time) | 50 |
B6 (flow control) | RTS/CTS |
B7 (RS timeout) | 20 |
B8 (transfer timeout) | 20 |
B9 (DC2/DC4) | No |
B10 (DC3 when finished) | No |
Read/Write |
Parameter | Value |
1 (device number) | CN0 |
2 (tape delimiting code) | Null |
3 (stop bits) | 1 |
4 (parity) | None |
5 (baud rate) | 4800 |
6 (flow control) | RTS/CTS |
7 | 8 bit JIS |
8 (ready time) | 50 |
9 (data bits) | 8 |
Set the following parameters on the PC
Serial port tab
Machine name | Okuma - Okuma 100-EL |
Serial port | COM2 (or any free COM port) |
Baud | 4800 |
Data bits | 7 |
Parity | Even |
Stop bits | 2 |
Data flow control tab
Use DTR | False |
Use RTS | True |
Require DSR | False |
Require CTS | True |
Set RTS | False |
Set DTR | False |
Software flowcontrol | None |
Xon char | #11 |
Xoff char | #13 |
Data exchange format tab
Format mode | Uniform |
Format parameters | Program start: %
Program end: %
Line start:
Line end: #0D#0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No |
Null modem cable, without handshake
PC, 9pin, DB9M | CNC, 25pin, DB25
Null modem cable, with full handshake
PC, 9pin, DB25M | CNC, 25pin, DB25
Null modem cable, without handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
Null modem cable, with full handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
If you have successfully connected DNC Precision
with any other controller not in this list, we would appreciate your sending us the
details to add to the list.
Note: We are not responsible and do not provide guarantee for any of these