DNC software for your Victor Taichung machine.
Upload and download NC programs.
Victor Taichung - H630 - NC settings
Communication parameters in the program to connect with H630
Serial port tab| Machine name | Victor Taichung - H630 |
| Serial port | COM2 (or any free COM port) |
| Baud | 4800 |
| Data bits | 7 |
| Parity | Even |
| Stop bits | 1 |
Data flow control tab| Use DTR | False |
| Use RTS | True |
| Require DSR | False |
| Require CTS | True |
| Set RTS | False |
| Set DTR | False |
| Software flowcontrol | Both |
| Xon char | #11 |
| Xoff char | #13 |
Data exchange format tab| Format mode | Data reception |
| Format parameters | Program start: %% Program end: %% Line start: Line end: #0A Skip lines: Ignore characters: No characters for remove Remove blank lines: No Program name prefix: O Program starting characters in the file: No Program ending characters in the file: No |
Victor Taichung - V105 - Machine parameters
Computer settings to connect with V105
Serial port tab| Machine name | Victor Taichung - V105 |
| Serial port | COM2 (or any free COM port) |
| Baud | 4800 |
| Data bits | 7 |
| Parity | Even |
| Stop bits | 1 |
Data flow control tab| Use DTR | False |
| Use RTS | True |
| Require DSR | False |
| Require CTS | True |
| Set RTS | False |
| Set DTR | False |
| Software flowcontrol | Both |
| Xon char | #11 |
| Xoff char | #13 |
Data exchange format tab| Format mode | Data reception |
| Format parameters | Program start: %% Program end: %% Line start: Line end: #0A Skip lines: Ignore characters: No characters for remove Remove blank lines: No Program name prefix: O Program starting characters in the file: No Program ending characters in the file: No |
Victor Taichung - V630 - Machine parameters
Set the following parameters on the PC for V630
Serial port tab| Machine name | Victor Taichung - V630 |
| Serial port | COM2 (or any free COM port) |
| Baud | 4800 |
| Data bits | 7 |
| Parity | Even |
| Stop bits | 1 |
Data flow control tab| Use DTR | False |
| Use RTS | True |
| Require DSR | False |
| Require CTS | True |
| Set RTS | False |
| Set DTR | False |
| Software flowcontrol | Both |
| Xon char | #11 |
| Xoff char | #13 |
Data exchange format tab| Format mode | Data reception |
| Format parameters | Program start: %% Program end: %% Line start: Line end: #0A Skip lines: Ignore characters: No characters for remove Remove blank lines: No Program name prefix: O Program starting characters in the file: No Program ending characters in the file: No |
Go to Index page
Traub - Traub system TX-8-k
Tanaka
Viking 100
Wenzler MTA-6
If you connected DNC Precision to another controller that is not on this list, please send us the information so we can add it to the list.