Connect Herholdt Controls to the computer through a USB-to-serial or RS485 adapter and read its registers in your browser: click "Read register values online" under the model (Chrome or Edge, nothing to install). The tables below list the MODBUS offset, unit, data type and scale of every register shown.
For logging 24/7 into a database, CSV files or Excel, use the Advanced Serial Data Logger (for MODBUS RTU) or Advanced TCP/IP Data Logger (for MODBUS TCP): they poll the complete map of every model on this page and provide continuous Herholdt Controls data logger and record.
read as 0 when the counter and interface combination (Basic or Full) does not support them
Registers in the map: 69 (the first 50 are listed below; the browser reader and the data loggers use the complete map). function 3 (holding registers). byte order big-endian. data types: dword, int64, word.
MODBUS offset
Description
Units
Data type
Scale
4099
Device type
word
4100
Firmware version
word
4101
Range overflow alarm
word
4102
Running tariff
dword
4104
PID bytes 1 and 2
word
4105
PID bytes 3 and 4
word
4106
PID bytes 5 and 6
word
4107
PID bytes 7 and 8
word
4108
PID bytes 9 and 10
word
4109
PID bytes 11 and 12
word
4110
PID bytes 13 and 14
word
4119
Active energy 1st phase T1, imp
kWh
int64
formula
4123
Active energy 2nd phase T1, imp
kWh
int64
formula
4127
Active energy 3rd phase T1, imp
kWh
int64
formula
4131
Active energy sum T1, imp
kWh
int64
formula
4135
Active energy 1st phase T2, imp
kWh
int64
formula
4139
Active energy 2nd phase T2, imp
kWh
int64
formula
4143
Active energy 3rd phase T2, imp
kWh
int64
formula
4147
Active energy sum T2, imp
kWh
int64
formula
4151
Active power 1st phase
dword
4153
Active power 2nd phase
dword
4155
Active power 3rd phase
dword
4157
Active power sum
int64
formula
4161
Active energy 1st phase T1, exp
kWh
int64
formula
4165
Active energy 2nd phase T1, exp
kWh
int64
formula
4169
Active energy 3rd phase T1, exp
kWh
int64
formula
4173
Active energy sum T1, exp
kWh
int64
formula
4177
Active energy 1st phase T2, exp
kWh
int64
formula
4181
Active energy 2nd phase T2, exp
kWh
int64
formula
4185
Active energy 3rd phase T2, exp
kWh
int64
formula
4189
Active energy sum T2, exp
kWh
int64
formula
4193
Reactive energy 1st phase T1, imp
kvarh
int64
formula
4197
Reactive energy 2nd phase T1, imp
kvarh
int64
formula
4201
Reactive energy 3rd phase T1, imp
kvarh
int64
formula
4205
Reactive energy sum T1, imp
kvarh
int64
formula
4209
Reactive energy 1st phase T2, imp
kvarh
int64
formula
4213
Reactive energy 2nd phase T2, imp
kvarh
int64
formula
4217
Reactive energy 3rd phase T2, imp
kvarh
int64
formula
4221
Reactive energy sum T2, imp
kvarh
int64
formula
4225
Reactive energy 1st phase T1, exp
kvarh
int64
formula
4229
Reactive energy 2nd phase T1, exp
kvarh
int64
formula
4233
Reactive energy 3rd phase T1, exp
kvarh
int64
formula
4237
Reactive energy sum T1, exp
kvarh
int64
formula
4241
Reactive energy 1st phase T2, exp
kvarh
int64
formula
4245
Reactive energy 2nd phase T2, exp
kvarh
int64
formula
4249
Reactive energy 3rd phase T2, exp
kvarh
int64
formula
4253
Reactive energy sum T2, exp
kvarh
int64
formula
4257
Reactive power 1st phase
kvar
dword
4259
Reactive power 2nd phase
kvar
dword
4261
Reactive power 3rd phase
kvar
dword
This is not the complete map: 50 of 69 registers are listed above. Click "Read register values online" to read any register of your device in the browser, or download the program to log the complete map.
4117, float or integer format, selectable big or little endian
Data format
32-bit values use 2 registers, 64-bit values use 4 registers scaled by 10000
Registers in the map: 83 (the first 50 are listed below; the browser reader and the data loggers use the complete map). function 3 (holding registers). byte order big-endian. data types: dword, int64, word.
MODBUS offset
Description
Units
Data type
Scale
4100
Firmware version
word
4101
Range overflow alarm
word
4102
Running tariff
word
4103
Read-only not used register
word
4104
PID, product identification bytes 1 and 2
word
4105
PID bytes 3 and 4
word
4106
PID bytes 5 and 6
word
4107
PID bytes 7 and 8
word
4108
PID bytes 9 and 10
word
4109
PID bytes 11 and 12
word
4110
PID bytes 13 and 14
word
4118
Reset energy counters command
word
4119
Active energy, L1, T1, imported
kWh
int64
4123
Active energy, L2, T1, imported
kWh
int64
4127
Active energy, L3, T1, imported
kWh
int64
4131
Active energy, sum, T1, imported
kWh
int64
4135
Active energy, L1, T2, imported
kWh
int64
4139
Active energy, L2, T2, imported
kWh
int64
4143
Active energy, L3, T2, imported
kWh
int64
4147
Active energy, sum, T2, imported
kWh
int64
4151
Active power, L1
kW
dword
4153
Active power, L2
kW
dword
4155
Active power, L3
kW
dword
4157
Active power, sum
kW
int64
4161
Active energy, L1, T1, exported
kWh
int64
4165
Active energy, L2, T1, exported
kWh
int64
4169
Active energy, L3, T1, exported
kWh
int64
4173
Active energy, sum, T1, exported
kWh
int64
4177
Active energy, L1, T2, exported
kWh
int64
4181
Active energy, L2, T2, exported
kWh
int64
4185
Active energy, L3, T2, exported
kWh
int64
4189
Active energy, sum, T2, exported
kWh
int64
4193
Reactive energy, L1, T1, imported
kvarh
int64
4197
Reactive energy, L2, T1, imported
kvarh
int64
4201
Reactive energy, L3, T1, imported
kvarh
int64
4205
Reactive energy, sum, T1, imported
kvarh
int64
4209
Reactive energy, L1, T2, imported
kvarh
int64
4213
Reactive energy, L2, T2, imported
kvarh
int64
4217
Reactive energy, L3, T2, imported
kvarh
int64
4221
Reactive energy, sum, T2, imported
kvarh
int64
4225
Reactive energy, L1, T1, exported
kvarh
int64
4229
Reactive energy, L2, T1, exported
kvarh
int64
4233
Reactive energy, L3, T1, exported
kvarh
int64
4237
Reactive energy, sum, T1, exported
kvarh
word
4241
Reactive energy, L1, T2, exported
kvarh
int64
4245
Reactive energy, L2, T2, exported
kvarh
int64
4249
Reactive energy, L3, T2, exported
kvarh
int64
4253
Reactive energy, sum, T2, exported
kvarh
int64
4257
Reactive power, L1
kvar
dword
4259
Reactive power, L2
kvar
dword
This is not the complete map: 50 of 83 registers are listed above. Click "Read register values online" to read any register of your device in the browser, or download the program to log the complete map.
Note: Products and companies mentioned here are used only for definition and identification purposes and can be trademarks and/or registered trademarks of the respective companies.
Your current browser does not support the Web Serial API required to access local COM ports. Please use a Chromium-based browser like Google Chrome, Microsoft Edge, or Opera.