Victron Multiplus II CCGX MODBUS registers: read online

Connect Victron to the computer through a USB-to-serial or RS485 adapter and read its registers in your browser: click "Read register values online" under the model (Chrome or Edge, nothing to install). The tables below list the MODBUS offset, unit, data type and scale of every register shown. For logging 24/7 into a database, CSV files or Excel, use the Advanced Serial Data Logger (for MODBUS RTU) or Advanced TCP/IP Data Logger (for MODBUS TCP): they poll the complete map of every model on this page and provide continuous Victron modbus logging and log.

Do you not know the meter address? Scan the device address online

Victron (Multiplus II CCGX) - MODBUS Values

Connection and addressing notes

Protocol
Modbus TCP
Default device address
100
Device address meaning
unit-id for the com.victronenergy.system data
Register addressing
decimal
Register set grouping
one register set per dbus service (column dbus-service-name)

Registers in the map: 817 (the first 50 are listed below; the browser reader and the data loggers use the complete map). function 3 (holding registers). byte order big-endian. data types: dword, integer, smallint, string(12), string(14), string(16), string(32), word.

MODBUS offsetDescriptionUnitsData typeScale
834GX firmware major version word 
835GX firmware beta release word 
800Serial (System) string(12) 
806CCGX relay 1 state word 
807CCGX relay 2 state word 
808PV - AC-coupled on output L1Wword 
809PV - AC-coupled on output L2Wword 
810PV - AC-coupled on output L3Wword 
811PV - AC-coupled on input L1Wword 
812PV - AC-coupled on input L2Wword 
813PV - AC-coupled on input L3Wword 
814PV - AC-coupled on generator L1Wword 
815PV - AC-coupled on generator L2Wword 
816PV - AC-coupled on generator L3Wword 
817AC consumption L1Wword 
818AC consumption L2Wword 
819AC consumption L3Wword 
820Grid L1Wsmallint 
821Grid L2Wsmallint 
822Grid L3Wsmallint 
823Genset L1Wsmallint 
824Genset L2Wsmallint 
825Genset L3Wsmallint 
826Active input source smallint 
840Battery voltage (System)V DCword×0.1
841Battery current (System)A DCsmallint×0.1
842Battery power (System)Wsmallint 
843Battery state of charge (System)%word 
844Battery state (System) word 
845Battery consumed amphours (System)Ahword×0.1
846Battery time to go (System)sword×100
850PV - DC-coupled powerWword 
851PV - DC-coupled currentA DCsmallint×0.1
855Charger powerWword 
860DC system powerWsmallint 
865VE.Bus charge current (System)A DCsmallint×0.1
866VE.Bus charge power (System)Wsmallint 
872Power between meter and inverter/charger, L1Winteger 
874Power between meter and inverter/charger, L2Winteger 
876Power between meter and inverter/charger, L3Winteger 
878Power on output of inverter/charger, L1Winteger 
880Power on output of inverter/charger, L2Winteger 
882Power on output of inverter/charger, L3Winteger 
884PV - AC-coupled on output L1Wdword 
886PV - AC-coupled on output L2Wdword 
888PV - AC-coupled on output L3Wdword 
890PV - AC-coupled on input L1Wdword 
892PV - AC-coupled on input L2Wdword 
894PV - AC-coupled on input L3Wdword 
896PV - AC-coupled on generator L1Wdword 

This is not the complete map: 50 of 817 registers are listed above. Click "Read register values online" to read any register of your device in the browser, or download the program to log the complete map.