Cewe (CDM) data logging. MODBUS registers map.
This data is being extracted with the help of the Advanced Serial Data Logger (MODBUS RTU,ASCII) or Advanced TCP/IP Data Logger (MODBUS TCP) software only. It may not applicable for other software titles.
MODBUS offset | Description | Units | Data type |
4096 | V1 L N voltage phase 1 | V | single |
4098 | V2 L N voltage phase 2 | V | single |
4100 | V3 L N voltage phase 3 | V | single |
4102 | V12 L L voltage line 12 | V | single |
4104 | V23 L L voltage line 23 | V | single |
4106 | V31 L L voltage line 31 | V | single |
4108 | V system voltage | V | single |
4110 | A1 phase 1 current | A | single |
4112 | A2 phase 2 current | A | single |
4114 | A3 phase 3 current | A | single |
4116 | An neutral current | A | single |
4118 | A system current | A | single |
4120 | PF1 phase 1 power factor | | single |
4122 | PF2 phase 2 power factor | | single |
4124 | PF3 phase 3 power factor | | single |
4126 | Pf system power factor | | single |
4128 | P1 phase 1 active power | W | single |
4130 | P2 phase 2 active power | W | single |
4132 | P3 phase 3 active power | W | single |
4134 | P system active power | W | single |
4136 | S1 phase 1 apparent power | VA | single |
4138 | S2 phase 2 apparent power | VA | single |
4140 | S3 phase 3 apparent power | VA | single |
4142 | S system apparent power | VA | single |
4144 | Q1 phase 1 reactive power | var | single |
4146 | Q2 phase 2 reactive power | var | single |
4148 | Q3 phase 3 reactive power | var | single |
4150 | Q system reactive power | var | single |
4152 | F frequency | Hz | single |
4352 | +kwh1 phase 1 imported active energy | Wh | single |
4354 | +kwh2 phase 2 imported active energy | Wh | single |
4356 | +kwh3 phase 3 imported active energy | Wh | single |
4358 | +kwh system imported active energy | Wh | single |
4360 | Kwh1 phase 1 exported active energy | Wh | single |
4362 | Kwh2 phase 2 exported active energy | Wh | single |
4364 | Kwh3 phase 3 exported active energy | Wh | single |
4366 | Kwh system exported active energy | Wh | single |
4368 | +kvah1 L phase 1 imported lagging apparent energy | VAh | single |
4370 | +kvah2 L phase 2 imported lagging apparent energy | VAh | single |
4372 | +kvah3 L phase 3 imported lagging apparent energy | VAh | single |
4374 | +kvah L system imported lagging apparent energy | VAh | single |
4376 | Kvah1 L phase 1 exported lagging apparent energy | VAh | single |
4378 | Kvah2 L phase 2 exported lagging apparent energy | VAh | single |
4380 | Kvah3 L phase 3 exported lagging apparent energy | VAh | single |
4382 | Kvah L system exported lagging apparent energy | VAh | single |
4384 | +kvah1 C phase 1 imported leading apparent energy | VAh | single |
4386 | +kvah2 C phase 2 imported leading apparent energy | VAh | single |
4388 | +kvah3 C phase 3 imported leading apparent energy | VAh | single |
4390 | +kvah C system imported leading apparent energy | VAh | single |
4392 | Kvah1 C phase 1 exported leading apparent energy | VAh | single |
There are more MODBUS items for this device. Please, download the program. |