Chint Power CPS MODBUS registers: read online

Connect Chint Power to the computer through a USB-to-serial or RS485 adapter and read its registers in your browser: click "Read register values online" under the model (Chrome or Edge, nothing to install). The tables below list the MODBUS offset, unit, data type and scale of every register shown. For logging 24/7 into a database, CSV files or Excel, use the Advanced Serial Data Logger (for MODBUS RTU) or Advanced TCP/IP Data Logger (for MODBUS TCP): they poll the complete map of every model on this page and provide continuous Chint Power data logger and record.

Do you not know the meter address? Scan the device address online

Chint Power (CPS) - MODBUS Measurements

Registers in the map: 25. function 4 (input registers). byte order big-endian. data types: int64, smallint, word.

MODBUS offsetDescriptionUnitsData typeScale
27Maximum active ac power during the daykWword×0.1
29Active ac power readingkWword×0.1
30Apparent ac power readingkVAword×0.1
31Grid voltage uabVword×0.1
32Grid voltage ubcVword×0.1
33Grid voltage ucaVword×0.1
34Grid A phase currentAword×0.1
35Grid B phase currentAword×0.1
36Grid C phase currentAword×0.1
37Dc voltage, mppt zone 1Vword×0.1
38Dc current, mppt zone 1Aword×0.1
39DC2 voltage, mppt zone 2Vword 
40DC2 current, mppt zone 2Aword×0.1
43Grid frequencyHzword×0.1
44Power module heatsink temperaturedeg Csmallint×0.1
45Internal inverter temperaturedeg Csmallint×0.1
47Inverter operation state word 
48Error timestamp int64 
52Permanent fault (pfault) word 
53Warning alarm register word 
54Fault0 alarm register word 
55Fault1 alarm register word 
56Fault2 alarm register word 
57Fault3 alarm register (23 36kw only) word 
58Fault4 alarm register (23 36kw only) word 