MODBUS offset | Description | Units | Data type |
769 | Phase 1 : phase voltage | V | dword |
773 | Phase 2 : phase voltage | V | dword |
777 | Phase 3 : phase voltage | V | dword |
781 | Phase 1 : current | A | dword |
785 | Phase 2 : current | A | dword |
789 | Phase 3 : current | A | dword |
793 | 3 phase : active power | W/var/VA | dword |
797 | 3 phase : reactive power | W/var/VA | dword |
801 | 3 phase : apparent power | W/var/VA | dword |
805 | 3 phase : positive active energy | Wh | dword |
809 | Chained voltage : L1 L2 | V | dword |
813 | Chained voltage : L2 L3 | V | dword |
817 | Chained voltage : L3 L1 | V | dword |
821 | 3 phase : partial positive active energy | Wh | dword |
825 | Frequency | Hz | word |
829 | 3 phase : power factor | | word |
831 | 3 phase : sector of power factor (cap or ind) | (1) | word |
835 | 3 phase : positive reactive energy | Wh | dword |
839 | 3 phase : sign of active power | (5) | word |
840 | Time counter | s | dword |
844 | 3 phase : sign of reactive power | (5) | word |
848 | 3 phase : average power | W/var/VA | dword |
852 | 3 phase : peak maximum demand | W/var/VA | dword |
856 | Time counter for average power | minutes | word |
857 | Neutro current | A | dword |
861 | Phase 1 : active power | W/var/VA | dword |
865 | Phase 2 : active power | W/var/VA | dword |
869 | Phase 3 : active power | W/var/VA | dword |
873 | Phase 1 : sign of active power | (5) | word |
874 | Phase 2 : sign of active power | (5) | word |
875 | Phase 3 : sign of active power | (5) | word |
876 | Phase 1 : reactive power | W/var/VA | dword |
880 | Phase 2 : reactive power | W/var/VA | dword |
884 | Phase 3 : reactive power | W/var/VA | dword |
888 | Phase 1 : sign of reactive power | (5) | word |
889 | Phase 2 : sign of reactive power | (5) | word |
890 | Phase 3 : sign of reactive power | (5) | word |
891 | Phase 1 : average current | A | dword |
895 | Phase 2 : average current | A | dword |
899 | Phase 3 : average current | A | dword |
903 | Phase 1 : current maximum demand | A | dword |
907 | Phase 2 : current maximum demand | A | dword |
911 | Phase 3 : current maximum demand | A | dword |
915 | Phase 1 : thd voltage | % | word |
917 | Phase 2 : thd voltage | % | word |
919 | Phase 3 : thd voltage | % | word |
921 | Phase 1 : thd current | % | word |
922 | Phase 2 : thd current | % | word |
924 | Phase 3 : thd current | % | word |
200 | Reset (r/w) bit to bit defined | (6) | word |
There are more MODBUS items for this device. Please, download the program. |
IME (Conto D2) data logging
IME (Nemo 72) data logging
IME (Nemo 96) data logging
IME (Nemo D4-DC) data logging
IME (Nemo D4-LE) data logging
IME (Nemo D4-LP) data logging
Note: Products and companies mentioned here are used only for definition and identification purposes and can be trademarks and/or registered trademarks of the respective companies.