Connect KOSTAL to the computer through a USB-to-serial or RS485 adapter and read its registers in your browser: click "Read register values online" under the model (Chrome or Edge, nothing to install). The tables below list the MODBUS offset, unit, data type and scale of every register shown. For logging 24/7 into a database, CSV files or Excel, use the Advanced Serial Data Logger (for MODBUS RTU) or Advanced TCP/IP Data Logger (for MODBUS TCP): they poll the complete map of every model on this page and provide continuous KOSTAL data logging and capture.

Do you not know the meter address? Scan the device address online

KOSTAL (Piko CI) - MODBUS Registers

Registers in the map: 131 (the first 50 are listed below; the browser reader and the data loggers use the complete map). function 3 (holding registers). byte order big-endian. data types: dword, single, smallint, word.

MODBUS offsetDescriptionUnitsData typeScale
40070AC CurrentAword×10A_SF
40071Phase A CurrentAword×10A_SF
40072Phase B CurrentAword×10A_SF
40073Phase C CurrentAword×10A_SF
40074Scale factor [A_SF] smallint 
40075Phase Voltage ABVword×10V_SF
40076Phase Voltage BCVword×10V_SF
40077Phase Voltage CAVword×10V_SF
40078Phase Voltage ANVword×10V_SF
40079Phase Voltage BNVword×10V_SF
40080Phase Voltage CNVword×10V_SF
40081Scale factor [V_SF] smallint 
40082AC PowerWsmallint×10W_SF
40083Scale factor [W_SF] smallint 
40084Line FrequencyHzword×10HZ_SF
40085Scale factor [HZ_SF] smallint 
40086AC Apparent PowerVAsmallint×10VA_SF
40087Scale factor [VA_SF] smallint 
40088AC Reactive Powervarsmallint×10VAR_SF
40089Scale factor [VAR_SF] smallint 
40090AC Power Factor%smallint×10PF_SF
40091Scale factor [PF_SF] smallint 
40092AC EnergyWhdword×10WH_SF
40094Scale factor [WH_SF] smallint 
40095DC CurrentAword×10DCA_SF
40096Scale factor [DCA_SF] smallint 
40097DC VoltageVword×10DCV_SF
40098Scale factor [DCV_SF] smallint 
40099DC PowerWsmallint×10DCW_SF
40100Scale factor [DCW_SF] smallint 
40101Cabinet Temperaturedeg Csmallint×10TMP_SF
40102Heat Sink Temperaturedeg Csmallint×10TMP_SF
40103Transformer Temperaturedeg Csmallint×10TMP_SF
40104Other Temperaturedeg Csmallint×10TMP_SF
40105Scale factor [TMP_SF] smallint 
40106Enumerated value. Operating state word 
40107Vendor specific operating state code word 
40108Bitmask value. Event fields dword 
40110Reserved for future use dword 
40112Vendor defined events dword 
40114Vendor defined events dword 
40116Vendor defined events dword 
40118Vendor defined events dword 
40122AC CurrentAsingle 
40124Phase A CurrentAsingle 
40126Phase B CurrentAsingle 
40128Phase C CurrentAsingle 
40130Phase Voltage ABVsingle 
40132Phase Voltage BCVsingle 
40134Phase Voltage CAVsingle 

This is not the complete map: 50 of 131 registers are listed above. Click "Read register values online" to read any register of your device in the browser, or download the program to log the complete map.

Kostal (Piko IQ,Plenticore) - MODBUS Mapping

Connection and addressing notes

Protocol
Modbus TCP
Default device address
71 (unit ID, modifiable)
Default TCP port
1502
Function codes
0x03 read, 0x06 write
Register addressing
0-based addresses given in both hex and decimal

Registers in the map: 105 (the first 50 are listed below; the browser reader and the data loggers use the complete map). function 3 (holding registers). byte order big-endian. data types: dword, single, smallint, string(16), string(32), string(64), word.

MODBUS offsetDescriptionUnitsData typeScale
6Inverter article number string(16) 
36Hardware version word 
38Software version maincontroller (mc) string(16) 
46Software version io controller (ioc) string(16) 
515Firmware maincontroller (mc) dword 
525Battery model id dword 
551Inverter model id string(16) 
586Battery firmware dword 
14Inverter serial number string(16) 
30Number of bidirectional converter word 
32Number of ac phases word 
34Number of pv strings word 
54Power id word 
56Inverter state2 word 
100Total dc powerWsingle 
104State of energy manager3 dword 
106Home own consumption from batteryWsingle 
108Home own consumption from gridWsingle 
110Total home consumption batteryWhsingle 
112Total home consumption gridWhsingle 
114Total home consumption pvWhsingle 
116Home own consumption from pvWsingle 
118Total home consumptionWhsingle 
120Isolation resistanceOhmsingle 
122Power limit from evu%single 
124Total home consumption rate%single 
144Worktimessingle 
150Actual cos single 
152Grid frequencyHzsingle 
154Current phase 1Asingle 
156Active power phase 1Wsingle 
158Voltage phase 1Vsingle 
160Current phase 2Asingle 
162Active power phase 2Wsingle 
164Voltage phase 2Vsingle 
166Current phase 3Asingle 
168Active power phase 3Wsingle 
170Voltage phase 3Vsingle 
172Total ac active powerWsingle 
174Total ac reactive powervarsingle 
178Total ac apparent powerVAsingle 
190Battery charge currentAsingle 
194Number of battery cycles single 
200Actual battery charge () / discharge (+) currentAsingle 
202Pssb fuse state5 single 
208Battery ready flag single 
210Act. State of charge%single 
214Battery temperature single 
216Battery voltageVsingle 
218Cos (powermeter) single 

This is not the complete map: 50 of 105 registers are listed above. Click "Read register values online" to read any register of your device in the browser, or download the program to log the complete map.

KOSTAL (KOSTAL Smart Energy Meter) - MODBUS Registers Map

Registers in the map: 72 (the first 50 are listed below; the browser reader and the data loggers use the complete map). function 3 (holding registers). byte order big-endian. data types: dword, smallint.

MODBUS offsetDescriptionUnitsData typeScale
40069Total AC CurrentAsmallint×10A_SF
40070Phase A CurrentAsmallint×10A_SF
40071Phase B CurrentAsmallint×10A_SF
40072Phase C CurrentAsmallint×10A_SF
40073Current scale factor smallint 
40074Line to Neutral AC Voltage (average of active phases)Vsmallint×10V_SF
40075Phase Voltage ANVsmallint×10V_SF
40076Phase Voltage BNVsmallint×10V_SF
40077Phase Voltage CNVsmallint×10V_SF
40078Line to Line AC Voltage (average of active phases)Vsmallint×10V_SF
40079PHVPHABVsmallint×10V_SF
40080PHVPHBCVsmallint×10V_SF
40081PHVPHCAVsmallint×10V_SF
40082Voltage scale factor smallint 
40083FrequencyHzsmallint×10HZ_SF
40084Frequency scale factor smallint 
40085Total Real PowerWsmallint×10W_SF
40086WPHAWsmallint×10W_SF
40087WPHBWsmallint×10W_SF
40088WPHCWsmallint×10W_SF
40089Real Power scale factor smallint 
40090AC Apparent PowerVAsmallint×10VA_SF
40091VAPHAVAsmallint×10VA_SF
40092VAPHBVAsmallint×10VA_SF
40093VAPHCVAsmallint×10VA_SF
40094Apparent Power scale factor smallint 
40095Reactive Powervarsmallint×10VAR_SF
40096VARPHAvarsmallint×10VAR_SF
40097VARPHBvarsmallint×10VAR_SF
40098VARPHCvarsmallint×10VAR_SF
40099Reactive Power scale factor smallint 
40100Power Factor%smallint×10PF_SF
40101PFPHA%smallint×10PF_SF
40102PFPHB%smallint×10PF_SF
40103PFPHC%smallint×10PF_SF
40104Power Factor scale factor smallint 
40105Total Real Energy ExportedWhdword×10TOTWH_SF
40107TOTWHEXPPHAWhdword×10TOTWH_SF
40109TOTWHEXPPHBWhdword×10TOTWH_SF
40111TOTWHEXPPHCWhdword×10TOTWH_SF
40113Total Real Energy ImportedWhdword×10TOTWH_SF
40115TOTWHIMPPHAWhdword×10TOTWH_SF
40117TOTWHIMPPHBWhdword×10TOTWH_SF
40119TOTWHIMPPHCWhdword×10TOTWH_SF
40121Real Energy scale factor smallint 
40122Total Apparent Energy ExportedVAhdword×10TOTVAH_SF
40124TOTVAHEXPPHAVAhdword×10TOTVAH_SF
40126TOTVAHEXPPHBVAhdword×10TOTVAH_SF
40128TOTVAHEXPPHCVAhdword×10TOTVAH_SF
40130Total Apparent Energy ImportedVAhdword×10TOTVAH_SF

This is not the complete map: 50 of 72 registers are listed above. Click "Read register values online" to read any register of your device in the browser, or download the program to log the complete map.