SolarX Power (Hybrid X1,Hybrid X3,X1AC) logging. MODBUS registers map.
This data is being extracted with the help of the Advanced Serial Data Logger (MODBUS RTU,ASCII) or Advanced TCP/IP Data Logger (MODBUS TCP) software only. It may not applicable for other software titles.
MODBUS offset | Description | Units | Data type |
1 | Grid current (X1) | V | smallint |
2 | Grid power (X1) | W | smallint |
3 | Pv voltage1 (Hybrid) | V | word |
4 | Pv voltage2 (Hybrid) | V | word |
5 | Pv current1 (Hybrid) | A | word |
6 | Pv current2 (Hybrid) | A | word |
7 | Grid frequency (X1) | Hz | word |
8 | Temperature | | smallint |
9 | Run mode | | word |
10 | Powerdc1 (Hybrid) | W | word |
11 | Powerdc2 (Hybrid) | W | word |
12 | Temper fault value | | smallint |
13 | Pv1Volt fault value | V | word |
14 | Pv2Volt fault value | V | word |
15 | Gfci fault value | mA | word |
16 | Grid volt fault value | V | word |
17 | Grid freq fault value T | Hz | word |
18 | Dci fault value | mA | word |
19 | Time count down | ms | word |
20 | Bat voltage charge1 | V | smallint |
21 | Bat current charge1 | A | smallint |
22 | Batpower charge1 | W | smallint |
23 | BMS connect state | | word |
24 | Temperature bat | | smallint |
28 | Battery capacity | % | word |
29 | Output energy Charge.LSB | KWh | word |
30 | Output energy Charge.MSB | KWh | word |
31 | BMS warning LSB | | word |
32 | Output energy charge today | KWh | word |
33 | Input energy Charge.LSB | KWh | word |
34 | Input energy Charge.MSB | KWh | word |
35 | Input energy charge today | KWh | word |
36 | BMS charge max current | A | word |
37 | BMS discharge max current | A | word |
38 | BMS warning MSB | | word |
64 | Inv fault Message.LSB | | word |
65 | Inv fault Message.MSB | | word |
67 | Mgr fault message | | word |
70 | Feedin power (meter) | w | integer |
72 | Feedin energy total (meter) | kwh | dword |
74 | Consum energy total (meter) | kwh | dword |
76 | EPS volt (X1) | V | word |
77 | EPS current (X1) | A | word |
78 | EPS power (X1) | VA | word |
79 | EPS frequency (X1) | Hz | word |
80 | Etoday togrid | kwh | word |
82 | Etotal togrid | kwh | dword |
84 | Lock state | | word |
102 | Bus volt | V | word |
103 | W dcv fault val | V | word |
There are more MODBUS items for this device. Please, download the program. |