SolarX Power Hybrid X1, Hybrid X3, X1AC MODBUS registers: read online

Connect SolarX Power to the computer through a USB-to-serial or RS485 adapter and read its registers in your browser: click "Read register values online" under the model (Chrome or Edge, nothing to install). The tables below list the MODBUS offset, unit, data type and scale of every register shown. For logging 24/7 into a database, CSV files or Excel, use the Advanced Serial Data Logger (for MODBUS RTU) or Advanced TCP/IP Data Logger (for MODBUS TCP): they poll the complete map of every model on this page and provide continuous SolarX Power modbus logging and log.

Do you not know the meter address? Scan the device address online

SolarX Power (Hybrid X1,Hybrid X3,X1AC) - MODBUS Values

Connection and addressing notes

Protocol
Modbus RTU, Modbus TCP
Function codes
04 read input registers
Register addressing
addresses start at 0x0000
Data format
32-bit values sent as two consecutive 16-bit registers
Word order
low word first (0x0046 is the LSB, 0x0047 the MSB)

Registers in the map: 100 (the first 50 are listed below; the browser reader and the data loggers use the complete map). function 4 (input registers). byte order big-endian. data types: dword, integer, smallint, word.

MODBUS offsetDescriptionUnitsData typeScale
1Grid current (X1)Vsmallint×0.1
2Grid power (X1)Wsmallint 
3Pv voltage1 (Hybrid)Vword×0.1
4Pv voltage2 (Hybrid)Vword×0.1
5Pv current1 (Hybrid)Aword×0.1
6Pv current2 (Hybrid)Aword×0.1
7Grid frequency (X1)Hzword×0.01
8Temperature smallint 
9Run mode word 
10Powerdc1 (Hybrid)Wword 
11Powerdc2 (Hybrid)Wword 
12Temper fault value smallint 
13Pv1Volt fault valueVword×0.1
14Pv2Volt fault valueVword×0.1
15Gfci fault valueAword×0.001
16Grid volt fault valueVword×0.1
17Grid freq fault value THzword×0.01
18Dci fault valueAword×0.001
19Time count downmsword 
20Bat voltage charge1Vsmallint×0.1
21Bat current charge1Asmallint×0.1
22Batpower charge1Wsmallint 
23BMS connect state word 
24Temperature bat smallint 
28Battery capacity%word 
29Output energy Charge.LSBkWhword×0.1
30Output energy Charge.MSBkWhword×0.1
31BMS warning LSB word 
32Output energy charge todaykWhword×0.1
33Input energy Charge.LSBkWhword×0.1
34Input energy Charge.MSBkWhword×0.1
35Input energy charge todaykWhword×0.1
36BMS charge max currentAword×0.1
37BMS discharge max currentAword×0.1
38BMS warning MSB word 
64Inv fault Message.LSB word 
65Inv fault Message.MSB word 
67Mgr fault message word 
70Feedin power (meter)Winteger 
72Feedin energy total (meter)kWhdword×0.01
74Consum energy total (meter)kWhdword×0.01
76EPS volt (X1)Vword×0.1
77EPS current (X1)Aword×0.1
78EPS power (X1)VAword 
79EPS frequency (X1)Hzword×0.01
80Etoday togridkWhword×0.1
82Etotal togridkWhdword×0.001
84Lock state word 
102BusVword×0.1
103W dcv fault valVword×0.1

This is not the complete map: 50 of 100 registers are listed above. Click "Read register values online" to read any register of your device in the browser, or download the program to log the complete map.