SolarX Power (Hybrid X1,Hybrid X3,X1AC) logger. MODBUS registers map.


This data is being extracted with the help of the Advanced Serial Data Logger (MODBUS RTU,ASCII) or Advanced TCP/IP Data Logger (MODBUS TCP) software only. It may not applicable for other software titles.

MODBUS offsetDescriptionUnitsData type
1Grid current (X1)Vsmallint
2Grid power (X1)Wsmallint
3Pv voltage1 (Hybrid)Vword
4Pv voltage2 (Hybrid)Vword
5Pv current1 (Hybrid)Aword
6Pv current2 (Hybrid)Aword
7Grid frequency (X1)Hzword
8Temperature smallint
9Run mode word
10Powerdc1 (Hybrid)Wword
11Powerdc2 (Hybrid)Wword
12Temper fault value smallint
13Pv1Volt fault valueVword
14Pv2Volt fault valueVword
15Gfci fault valuemAword
16Grid volt fault valueVword
17Grid freq fault value THzword
18Dci fault valuemAword
19Time count downmsword
20Bat voltage charge1Vsmallint
21Bat current charge1Asmallint
22Batpower charge1Wsmallint
23BMS connect state word
24Temperature bat smallint
28Battery capacity%word
29Output energy Charge.LSBKWhword
30Output energy Charge.MSBKWhword
31BMS warning LSB word
32Output energy charge todayKWhword
33Input energy Charge.LSBKWhword
34Input energy Charge.MSBKWhword
35Input energy charge todayKWhword
36BMS charge max currentAword
37BMS discharge max currentAword
38BMS warning MSB word
64Inv fault Message.LSB word
65Inv fault Message.MSB word
67Mgr fault message word
70Feedin power (meter)winteger
72Feedin energy total (meter)kwhdword
74Consum energy total (meter)kwhdword
76EPS volt (X1)Vword
77EPS current (X1)Aword
78EPS power (X1)VAword
79EPS frequency (X1)Hzword
80Etoday togridkwhword
82Etotal togridkwhdword
84Lock state word
102Bus voltVword
103W dcv fault valVword
104W over load faultval word
105W battery volt fault valVword
106Grid voltage R (X3)Vword
107Grid current R (X3)Asmallint
108Grid power R (X3)Wsmallint
109Grid frequency R (X3)Hzword
110Grid voltage S (X3)Vword
111Grid current S (X3)Asmallint
112Grid power S (X3)Wsmallint
113Grid frequency S (X3)Hzword
114Grid voltage T (X3)Vword
115Grid current T (X3)Asmallint
116Grid power T (X3)Wsmallint
117Grid frequency T (X3)Hzword
118EPS volt R (X3)Vword
119EPS current R (X3)Aword
120Eps power active R (X3)Wword
121Eps power S R (X3)VAword
122EPS volt S (X3)Vword
123EPS current S (X3)Aword
124Eps power active S (X3)Wword
125Eps power S S (X3)VAword
126EPS volt T (X3)Vword
127EPS current T (X3)Aword
128Eps power active T (X3)Wword
129Eps power S T (X3)VAword
132Feedin power sphase (X3)Winteger
134Feedin power tphase (X3)Winteger
136Grid mode run time (X3)Hinteger
138Eps mode run time (X3)Hinteger
140Noraml run time (X1)Hinteger
142Eps yield totalKWhdword
144Eps yield todayKWhword
145Echarge todayKWhword
146Echarge totalKWhdword
148Solar energy totalKWhdword
150Solar energy todayKWhword
152Feedin energy todaykwhword
154Consum energy todaykwhword
156W active power (0x9C:LSB, 0x9D:MSB)Winteger
194Bat voltage charge1Vsmallint
195Bat current charge1Asmallint
196Batpower charge1Wsmallint
197BMS connect state word
198Temperature bat smallint
199Capacity charge11word
200BMS warning Code.LSB word
201BMS charge max currentAword
202BMS discharge max currentAword
204BMS energy throughputWhdword
There are more MODBUS items for this device. Please, download the program.