DNC and CNC setting for Burny 3
These settings are for the DNC Precision software only. They may not work with other software.
Set the following parameters on the machine
PROTCL | 2 (XON/XOFF) |
PGM TYPE | 1 = (Standard Burny 3 word address program) |
CHAR TYPE | 5 (OP7D-ASCII, Odd parity, 7 data bits) |
BAUD RATE | 2400 |
Set the following parameters on the PC
Serial port tab
Machine name | Burny 3 |
Serial port | COM2 (or any free COM port) |
Baud | 2400 |
Data bits | 7 |
Parity | Odd |
Stop bits | 1 |
Data flow control tab
Use DTR | False |
Use RTS | False |
Require DSR | False |
Require CTS | False |
Set RTS | True |
Set DTR | True |
Software flowcontrol | Both |
Xon char | #14 |
Xoff char | #12 |
Data exchange format tab
Format mode | Uniform |
Format parameters | Program start: %%
Program end: %%
Line start:
Line end: #0D#0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: Yes
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No |
Null modem cable, without handshake
PC, 9pin, DB9M | CNC, 25pin, DB25
Null modem cable, with full handshake
PC, 9pin, DB25M | CNC, 25pin, DB25
Null modem cable, without handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
Null modem cable, with full handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
If you have successfully connected DNC Precision
with any other controller not in this list, we would appreciate your sending us the
details to add to the list.
Note: We are not responsible and do not provide guarantee for any of these
settings, that have been sent us by our customers.