bg

Dialog - DNC Software and CNC Settings

DNC software for your Dialog machine.
Upload and download NC programs.

Dialog-11 - Machine parameters

Set the following parameters on Dialog 11

DeviceChannel 1

Set the following parameters on the PC for 11

Serial port tab
Machine nameDialog-11
Serial portCOM2 (or any free COM port)
Baud4800
Data bits7
ParityNone
Stop bits1
Data flow control tab
Use DTRFalse
Use RTSTrue
Require DSRFalse
Require CTSTrue
Set RTSFalse
Set DTRFalse
Software flowcontrolNone
Xon char#11
Xoff char#13
Data exchange format tab
Format modeUniform
Format parametersProgram start:
Program end: M30
Line start:
Line end: #0D#0A
Skip lines: ;
Ignore characters: No characters for remove
Remove blank lines: Yes
Program name prefix:
Program starting characters in the file: No
Program ending characters in the file: Yes

Null modem cable, without handshake
PC, 9pin, DB9M | CNC, 25pin, DB25
 

Null modem cable, with full handshake
PC, 9pin, DB25M | CNC, 25pin, DB25
 

Null modem cable, without handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
 

Null modem cable, with full handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
 

Dialog-112 - DNC settings

Set the following parameters on Dialog 112

<1> <2> <3> <4>" />
Set the following I/O parameters on the machine.
#<0
#1 - Device namePC
#2 - Baud rate1 0 0 0 0
#3 - Stop bits1 0 0 0 0
#4 - Parity effective0 0 0 0 0
#5 - Even parity1 0 0 0 0
#6 - Char length3 0 0 0 0
#7 - Terminator type0 0 0 0 0
#8 - Code 100 00 00 00 00
#9 - Code 200 00 00 00 00
#10 - Rewind code0 0 0 0 0
#11 - Hand shake1 0 0 0 0
#12 - DC code parity0 0 0 0 0
#13 - DC2/DC4 output0 0 0 0 0
#14 - CR output1 0 0 0 0
#15 - EIA output0 0 0 0 0
#16 - Title feed out0 0 0 0 0
#17 - Feed chr.0 0 0 0 0
#18 - Parity V0 0 0 0 0
#19 - Timeout set0 0 0 0 0
#20 - RST ignore0 0 0 0 0
#21 - EIA code [00 00 00 00 00
#22 - ]00 00 00 00 00
#23 - #00 00 00 00 00
#24 - *00 00 00 00 00
#25 - =00 00 00 00 00
#25 - :00 00 00 00 00
#30 - Printer type0 0 0 0 0

Set the following parameters on the PC for 112

Serial port tab
Machine nameDialog-112
Serial portCOM2 (or any free COM port)
Baud9600
Data bits7
ParityEven
Stop bits1
Data flow control tab
Use DTRFalse
Use RTSTrue
Require DSRFalse
Require CTSTrue
Set RTSFalse
Set DTRFalse
Software flowcontrolNone
Xon char#11
Xoff char#13
Data exchange format tab
Format modeUniform
Format parametersProgram start: %%
Program end: %%
Line start:
Line end: #0D#0A
Skip lines: ;
Ignore characters: No characters for remove
Remove blank lines: Yes
Program name prefix: O
Program starting characters in the file: Yes
Program ending characters in the file: Yes

Null modem cable, without handshake
PC, 9pin, DB9M | CNC, 25pin, DB25
 

Null modem cable, with full handshake
PC, 9pin, DB25M | CNC, 25pin, DB25
 

Null modem cable, without handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
 

Null modem cable, with full handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
 

Dialog-2 - NC settings

Configure the controller on Dialog 2

The machine parameters can be set using the DIP switches available on the control panel.
This machine does not have an RS232C interface. K5 connector is available for audio interface must be connected to a DB-25 connector (which must be fixed to the panel)
DB25K5
111,12
217
313
420
516
618
711,12
6 connect with 20

Communication parameters in the program to connect with 2

Serial port tab
Machine nameDialog-2
Serial portCOM2 (or any free COM port)
Baud9600
Data bits7
ParityNone
Stop bits2
Data flow control tab
Use DTRFalse
Use RTSTrue
Require DSRFalse
Require CTSTrue
Set RTSFalse
Set DTRFalse
Software flowcontrolNone
Xon char#11
Xoff char#13
Data exchange format tab
Format modeUniform
Format parametersProgram start:
Program end: M30
Line start:
Line end: #0D#0A
Skip lines: ;
Ignore characters: No characters for remove
Remove blank lines: Yes
Program name prefix:
Program starting characters in the file: No
Program ending characters in the file: Yes

Null modem cable, without handshake
PC, 9pin, DB9M | CNC, 25pin, DB25
 

Null modem cable, with full handshake
PC, 9pin, DB25M | CNC, 25pin, DB25
 

Null modem cable, without handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
 

Null modem cable, with full handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
 

Dialog-4 - Machine parameters

Set the following parameters on the PC for 4

Serial port tab
Machine nameDialog-4
Serial portCOM2 (or any free COM port)
Baud2400
Data bits7
ParityNone
Stop bits2
Data flow control tab
Use DTRFalse
Use RTSTrue
Require DSRFalse
Require CTSTrue
Set RTSFalse
Set DTRFalse
Software flowcontrolNone
Xon char#11
Xoff char#13
Data exchange format tab
Format modeUniform
Format parametersProgram start: &%
Program end: M30#0D#0A
Line start:
Line end: #0D#0A
Skip lines: ;
Ignore characters: No characters for remove
Remove blank lines: Yes
Program name prefix:
Program starting characters in the file: No
Program ending characters in the file: Yes

Null modem cable, without handshake
PC, 9pin, DB9M | CNC, 25pin, DB25
 

Null modem cable, with full handshake
PC, 9pin, DB25M | CNC, 25pin, DB25
 

Null modem cable, without handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
 

Null modem cable, with full handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
 

Go to Index page
Delta Dynapath
DOOSAN HM630
Digma CNC
Eckelmann - Viewstar 750

If you connected DNC Precision to another controller that is not on this list, please send us the information so we can add it to the list.