Program start: Program end: M30 Line start: Line end: #0D#0A Skip lines: ; Ignore characters: No characters for remove Remove blank lines: Yes Program name prefix: Program starting characters in the file: No Program ending characters in the file: Yes
The machine parameters can be set using the DIP switches available on the control panel.
This machine does not have an RS232C interface. K5 connector is available for audio interface must be connected to a DB-25 connector (which must be fixed to the panel)
DB25
K5
1
11,12
2
17
3
13
4
20
5
16
6
18
7
11,12
6 connect with 20
Set the following parameters on the PC
Serial port tab
Machine name
Dialog-2
Serial port
COM2 (or any free COM port)
Baud
9600
Data bits
7
Parity
None
Stop bits
2
Data flow control tab
Use DTR
False
Use RTS
True
Require DSR
False
Require CTS
True
Set RTS
False
Set DTR
False
Software flowcontrol
None
Xon char
#11
Xoff char
#13
Data exchange format tab
Format mode
Uniform
Format parameters
Program start: Program end: M30 Line start: Line end: #0D#0A Skip lines: ; Ignore characters: No characters for remove Remove blank lines: Yes Program name prefix: Program starting characters in the file: No Program ending characters in the file: Yes
Program start: &% Program end: M30#0D#0A Line start: Line end: #0D#0A Skip lines: ; Ignore characters: No characters for remove Remove blank lines: Yes Program name prefix: Program starting characters in the file: No Program ending characters in the file: Yes