Set the following parameters on the machine
| 771 | 1 | 
| 772 (XON/XOFF enabled) | 3 | 
| 773 (buffer size) | 60 | 
| 775 (stop bits) | 0 | 
| 776 (baud rate) | 2400 | 
| 777 (baud rate) | 2400 | 
| 782 | 1 | 
| 785 | 1 | 
| 786 | 4800 | 
Set the following parameters on the PC
Serial port tab
| Machine name | Maho - CNC 432 - 1000 | 
| Serial port | COM2 (or any free COM port) | 
| Baud | 2400 | 
| Data bits | 7 | 
| Parity | Even | 
| Stop bits | 2 | 
Data flow control tab
| Use DTR | False | 
| Use RTS | True | 
| Require DSR | False | 
| Require CTS | True | 
| Set RTS | False | 
| Set DTR | False | 
| Software flowcontrol | None | 
| Xon char | #11 | 
| Xoff char | #13 | 
Data exchange format tab
| Format mode | Uniform | 
| Format parameters | Program start: Program end: ^ Line start: Line end: #0D#0A Skip lines: Ignore characters: No characters for remove Remove blank lines: No Program name prefix: O Program starting characters in the file: No Program ending characters in the file: No  | 
Null modem cable, without handshake
PC, 9pin, DB9M | CNC, 25pin, DB25
 Null modem cable, with full handshake
PC, 9pin, DB25M | CNC, 25pin, DB25
 Null modem cable, without handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
 Null modem cable, with full handshake
PC, 25pin, DB25M | CNC, 25pin, DB25