Program start: % Program end: % Line start: Line end: #0D#0A Skip lines: Ignore characters: No characters for remove Remove blank lines: No Program name prefix: O Program starting characters in the file: No Program ending characters in the file: No
Program start: % Program end: % Line start: Line end: #0D#0A Skip lines: Ignore characters: No characters for remove Remove blank lines: No Program name prefix: O Program starting characters in the file: No Program ending characters in the file: No
The program does not support the Mazatrol protocol
Change CNC parameters
FD I/O Mode
1 (ISO)
FD I/O STOP BIT
2 (2 bits)
FD I/O PARITY
0 (No Parity, but in DNCP you should use the Even parity)
FD I/O BAUD RATE
9600
Set the following parameters on the PC
Serial port tab
Machine name
Mazak - L32
Serial port
COM2 (or any free COM port)
Baud
9600
Data bits
7
Parity
Even
Stop bits
2
Data flow control tab
Use DTR
False
Use RTS
True
Require DSR
False
Require CTS
True
Set RTS
False
Set DTR
False
Software flowcontrol
Both
Xon char
#11
Xoff char
#13
Data exchange format tab
Format mode
Uniform
Format parameters
Program start: % Program end: % Line start: Line end: #0D#0A Skip lines: Ignore characters: No characters for remove Remove blank lines: No Program name prefix: O Program starting characters in the file: Yes Program ending characters in the file: Yes
The program does not support the Mazatrol protocol
Change user parameter #5
G1 (baud rate)
1 (9600)
G2 (stop bits)
3 (2 stop bits)
G3 (parity)
0 (Even)
G5 (data bits)
3 (8 data bits, but in the program you should specify 7 )
G6 (Terminattors)
1 (EOB or EOR)
G10
3 (Use DC handshaking)
G11
1 (Parity on DC output)
G12
0 (Don't output DC2 and DC4)
G13 (wait time)
50
G17
00000000
G31
00000000
G33 (feed section size)
50
G34 (number of spaces)
10
G39
00000100
G40
00000000
G48
0
Set the following parameters on the PC
Serial port tab
Machine name
Mazak - M plus
Serial port
COM2 (or any free COM port)
Baud
9600
Data bits
7
Parity
Even
Stop bits
2
Data flow control tab
Use DTR
False
Use RTS
True
Require DSR
False
Require CTS
True
Set RTS
False
Set DTR
False
Software flowcontrol
Both
Xon char
#11
Xoff char
#13
Data exchange format tab
Format mode
Uniform
Format parameters
Program start: % Program end: % Line start: Line end: #0D#0A Skip lines: Ignore characters: No characters for remove Remove blank lines: No Program name prefix: O Program starting characters in the file: No Program ending characters in the file: No
The program does not support the Mazatrol protocol
Change user parameter #5
G1 (baud rate)
2 (4800)
G2 (stop bits)
3 (2 stop bits)
G3 (parity)
0 (Even)
G5 (data bits)
3 (8 data bits, but in the program you should specify 7 )
G6 (Terminattors)
1 (EOB or EOR)
G7
0
G8
0
G9
0
G10
1
G11
1
G12
0
G13 (wait time)
50
G14
0
G15
0
G16
0
Set the following parameters on the PC
Serial port tab
Machine name
Mazak - M32 plus
Serial port
COM2 (or any free COM port)
Baud
4800
Data bits
7
Parity
Even
Stop bits
2
Data flow control tab
Use DTR
False
Use RTS
True
Require DSR
False
Require CTS
True
Set RTS
False
Set DTR
False
Software flowcontrol
None
Xon char
#11
Xoff char
#13
Data exchange format tab
Format mode
Uniform
Format parameters
Program start: % Program end: % Line start: Line end: #0D#0A Skip lines: Ignore characters: No characters for remove Remove blank lines: No Program name prefix: O Program starting characters in the file: No Program ending characters in the file: No
The program does not support the Mazatrol protocol
Change user parameter #5
G19 (baud rate)
2 (4800)
G20 (stop bits)
3 (2 stop bits)
G22 (parity)
0 (Even)
G23 (data bits)
3 (8 data bits, but in the program you should specify 7 )
G24
1
G25
0
G26
0
G27 (ISO CR output)
0
G28
0
G29 (handshake type)
3
Set the following parameters on the PC
Serial port tab
Machine name
Mazak - M32
Serial port
COM2 (or any free COM port)
Baud
4800
Data bits
7
Parity
Even
Stop bits
2
Data flow control tab
Use DTR
False
Use RTS
True
Require DSR
False
Require CTS
True
Set RTS
False
Set DTR
False
Software flowcontrol
None
Xon char
#11
Xoff char
#13
Data exchange format tab
Format mode
Uniform
Format parameters
Program start: % Program end: % Line start: Line end: #0D#0A Skip lines: Ignore characters: No characters for remove Remove blank lines: No Program name prefix: : Program starting characters in the file: No Program ending characters in the file: No
The program does not support the Mazatrol protocol
I1
2
I2
3
I3
0
I4
0
I5
3
I6
3
I7
1
I8
5
I9
0
I10
1
I11
1
I12
0
I13
0
I14
0
I15
30
I16
0
I24
0
I58
0000 0000
Set the following parameters on the PC
Serial port tab
Machine name
Mazak - T plus
Serial port
COM2 (or any free COM port)
Baud
4800
Data bits
8
Parity
None
Stop bits
2
Data flow control tab
Use DTR
False
Use RTS
True
Require DSR
False
Require CTS
True
Set RTS
False
Set DTR
False
Software flowcontrol
Both
Xon char
#11
Xoff char
#13
Data exchange format tab
Format mode
Uniform
Format parameters
Program start: Program end: Line start: Line end: #0D#0A Skip lines: Ignore characters: No characters for remove Remove blank lines: No Program name prefix: O Program starting characters in the file: No Program ending characters in the file: No
The program does not support the Mazatrol protocol
A15 (RS-232)
206
A16 (parity)
1 (None, but in a program configuration you should specify 7 data bits and Even parity)
A17 (baud rate)
6 (4800)
A18 (mode)
6 (read and punch)
A19
0
A20 (punch code)
1 (ISO)
A21
1
A22
10
A23
10
A24 (TV check)
0
A30
3
A31
109
A31
70
Set the following parameters on the PC
Serial port tab
Machine name
Mazak - T2
Serial port
COM2 (or any free COM port)
Baud
4800
Data bits
7
Parity
Even
Stop bits
1
Data flow control tab
Use DTR
False
Use RTS
True
Require DSR
False
Require CTS
True
Set RTS
False
Set DTR
False
Software flowcontrol
Both
Xon char
#11
Xoff char
#13
Data exchange format tab
Format mode
Uniform
Format parameters
Program start: Program end: Line start: Line end: #0D#0A Skip lines: Ignore characters: No characters for remove Remove blank lines: No Program name prefix: O Program starting characters in the file: No Program ending characters in the file: No
The program does not support the Mazatrol protocol
I1
2
I2
3
I3
0
I4
0
I5
3
I6
3
I7
1
I8
5
I9
0
I10
1
I11
1
I12
0
I13
0
I14
0
I15
30
I16
0
I24
0
I58
0000 0000
Set the following parameters on the PC
Serial port tab
Machine name
Mazak - T32 M2
Serial port
COM2 (or any free COM port)
Baud
4800
Data bits
7
Parity
Even
Stop bits
2
Data flow control tab
Use DTR
False
Use RTS
True
Require DSR
False
Require CTS
True
Set RTS
False
Set DTR
False
Software flowcontrol
Both
Xon char
#11
Xoff char
#13
Data exchange format tab
Format mode
Uniform
Format parameters
Program start: Program end: Line start: Line end: #0D#0A Skip lines: Ignore characters: No characters for remove Remove blank lines: No Program name prefix: O Program starting characters in the file: No Program ending characters in the file: No