DNC and CNC setting for Okuma - Okuma OSP-U100
These settings are for the DNC Precision software only. They may not work with other software.
Set the following parameters on the machine
Optional parameters |
Parameter | Value |
1 (tape code) | ISO |
2 (detect code automatically) | 1 (Yes) |
3 (tape TV check) | 0 (No) |
4 (program end code) | 1 (%) |
5 (tape ready verify) | 0 (No) |
6 (special code) | 0 (No alarm) |
7 (ignore special code) | 1 (Ignore) |
8 (file name output) | 0 (Output) |
9 (EOR code) | 0 (CR,LF) |
10 (punch empty character) | 0 (Null) |
11 (read device number) | 0 (CN0) |
12 (punch device number) | 0 (CN0) |
10 (tape feed) | 1 |
With help of the [PAGE DOWN] button go to tape interface (RS232 - CN0) parameters |
Parameter | Value |
1 (stop bits) | 1 |
2 (parity check) | 0 |
3 (parity) | 1 (Even) |
4 (8 bit JIS) | 1 (Yes) |
5 (DC2/DC4) | 0 (No) |
6 (file name read) | 1 (Execute) |
7 (CNC slave) | 0 (No, master) |
8 (baud rate) | 9600 |
9 (busy timeout) | 15 |
Set the following parameters on the PC
Serial port tab
Machine name | Okuma - Okuma OSP-U100 |
Serial port | COM2 (or any free COM port) |
Baud | 9600 |
Data bits | 7 |
Parity | Even |
Stop bits | 2 |
Data flow control tab
Use DTR | False |
Use RTS | True |
Require DSR | False |
Require CTS | True |
Set RTS | False |
Set DTR | False |
Software flowcontrol | None |
Xon char | #11 |
Xoff char | #13 |
Data exchange format tab
Format mode | Uniform |
Format parameters | Program start: %
Program end: %
Line start:
Line end: #0D#0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No |
Null modem cable, without handshake
PC, 9pin, DB9M | CNC, 25pin, DB25
Null modem cable, without handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
If you have successfully connected DNC Precision
with any other controller not in this list, we would appreciate your sending us the
details to add to the list.
Note: We are not responsible and do not provide guarantee for any of these