Acrel - MODBUS Registers Map - Data Logging

The data can be automatically logged 24/7 into a database, CSV files, or Excel spreadsheets using the Advanced Serial Data Logger (for MODBUS RTU) or Advanced TCP/IP Data Logger (for MODBUS TCP) software. These data logging tools provide continuous and reliable Acrel data logging and log.

Do you not know the meter address? Scan the device address online

Acrel (ADW300) - MODBUS Registers Map

MODBUS offset
Description
Units
Data type
1
2
 
word
20
Voltage of A phase
 
word
21
Voltage of B phase
 
word
22
Voltage of C phase
 
word
23
Voltage between A-B
 
word
24
Voltage between B-C
 
word
25
Voltage between C-A
 
word
26
Electricity of A phase
A
word
27
Electricity of B phase
A
word
28
Electricity of C phase
A
word
29
Vector sum of 3-phase current
A
word
30
Active power of A phase
kW
dword
32
Active power of B phase
kW
dword
34
Active power of C phase
kW
dword
36
Total active power
kW
dword
38
Reactive power of A phase
kVar
dword
40
Reactive power of B phase
kVar
dword
42
Reactive power of C phase
kVar
dword
44
Total reactive power
kVA
dword
46
Apparent power of A phase
kVA
dword
48
Apparent power of B phase
kVA
dword
50
Apparent power of C phase
kVA
dword
52
Total apparent power
kVA
dword
54
Power factor of A phase
 
word
55
Power factor of B phase
 
word
56
Power factor of C phase
 
word
57
Total power factor
 
word
58
State of DI
 
word
59
Frequency of power
 
word
60
Total energy consumption
kWh
dword
62
Forward active energy consumption
kWh
dword
64
Reversing active energy consumption
kWh
dword
66
Forward reactive energy consumption
kVarh
dword
68
Reversing reactive energy consumption
kVarh
dword
70
Total energy consumption on phase
kWh
dword
72
Forward active energy consumption on phase
kWh
dword
74
Reversing active energy consumption on phase
kWh
dword
76
Consumption on A phase
kVarh
dword
78
Reversing reactive energy consumption on phase
kVarh
dword
80
Total energy consumption on B phase
kWh
dword
82
Forward active energy consumption on B phase
kWh
dword
84
Reversing active energy consumption on B phase
kWh
dword
86
Forward reactive energy consumption on B phase
kVarh
dword
88
Reversing reactive energy consumption on B phase
kVarh
dword
90
Total energy consumption on phase
kWh
dword
92
Forward active energy consumption on C phase
kWh
dword
94
Reversing active energy consumption on C phase
kWh
dword
96
Forward reactive energy consumption on C phase
kVarh
dword
98
Reversing reactive energy consumption on C phase
kVarh
dword
100
Maximum forward active demand in current month
KW
dword
There are more MODBUS items for this device. Please download the program to discover all registers.

Acrel (DTSD1352) - MODBUS Registers Map

MODBUS offset
Description
Units
Data type
0
Current total active energy
kWh
dword
2
Current spike total active energy
kWh
dword
4
Current peak total active energy
kWh
dword
6
Current flat total active energy
kWh
dword
8
Current valley total active energy
kWh
dword
10
Current forward active total energy
kWh
dword
12
Current forward active spike energy
kWh
dword
14
Current forward active energy peak
kWh
dword
16
Current forward active flat energy
kWh
dword
18
Current forward active valley energy
kWh
dword
20
Current reversing active total energy
kWh
dword
22
Current reversing active spike energy
 
dword
24
Current reversing active energy peak
 
dword
26
Current reversing active flat energy
 
dword
28
Current reversing active valley energy
 
dword
30
Current total reactive energy
 
dword
32
Current total reactive spike energy
 
dword
34
Current total reactive peak energy
 
dword
36
Current total reactive flat energy
 
dword
38
Current total reactive energy valley
 
dword
40
Current forward reactive total energy
 
dword
42
Current forward reactive spike energy
 
dword
44
Current forward reactive energy peak
 
dword
46
Current forward reactive flat energy
 
dword
48
Current forward reactive valley energy
 
dword
50
Current reversing reactive total energy
 
dword
52
Current reversing reactive spike energy
 
dword
54
Current reversing reactive energy peak
 
dword
56
Current reversing reactive flat energy
 
dword
58
Current reversing reactive valley energy
 
dword
60
Time: second, minute
 
word
61
Time: hour; day
 
word
62
Time: month, year
 
word
64
Pulse constant
 
word
97
Voltage of A phase
V
word
98
Voltage of B phase
V
word
99
Voltage of C phase
V
word
100
Current of phase A
A
word
101
Current of phase B
A
word
102
Current of phase C
A
word
119
Frequency
Hz
word
120
Voltage between A-B
V
word
121
Voltage between C-B
V
word
122
Voltage between A-C
V
word
123
Forward active maximum demand
 
word
124
Time of occurrence: minute, hour
 
word
125
Time of occurrence: day, month
 
word
126
Reversing active maximum demand
 
word
127
Time of occurrence: minute, hour
 
word
128
Time of occurrence: day, month
 
word
There are more MODBUS items for this device. Please download the program to discover all registers.

Acrel (PZ300) - Data

MODBUS offset
Description
Units
Data type
0
1 voltage effective value
V
dword
2
2 voltage effective value
 
dword
4
3 voltage effective value
 
dword
6
Average voltage effective value
 
dword
8
1 current effective value
A
dword
10
2 current effective value
 
dword
12
3 current effective value
 
dword
14
Total current effective value
 
dword
16
1 active power effective value
W
dword
18
2 active power effective value
 
dword
20
3 active power effective value
 
dword
22
1 reactive power effective value
var
dword
24
2 reactive power effective value
 
dword
26
3 reactive power effective value
 
dword
28
1 apparent power effective value
VA
dword
30
2 apparent power effective value
 
dword
32
3 apparent power effective value
 
dword
34
1 power factor effective value
 
dword
36
2 power factor effective value
 
dword
38
3 power factor effective value
 
dword
40
Total active power effective value
W
dword
42
Total reactive power effective value
var
dword
44
Total apparent power effective value
VA
dword
46
Total power factor effective value
 
dword
48
Frequency effective value
Hz
dword
50
Pt ratio
 
word
51
Ct ratio
 
word
52
1 active electric energy
 
dword
54
2 active electric energy
 
dword
56
3 active electric energy
 
dword
58
Total active electric energy
 
dword
60
1 reactive electric energy
wh
dword
62
2 reactive electric energy
 
dword
64
3 reactive electric energy
 
dword
66
Total reactive electric energy
 
dword

Acrel (PZ72-E3,P80-E3,PZ96-E3) - MODBUS Registers Map

MODBUS offset
Description
Units
Data type
3
Pt ratio
 
word
4
Ct ratio
 
word
35
Decimal point U
 
word
36
Decimal point PQ
 
word
34
The statement of relays
 
word
37
Phase voltage A
V
word
38
Phase voltage B
V
word
39
Phase voltage C
V
word
40
Line voltage AB
V
word
41
Line voltage BC
V
word
42
Line voltage AC
V
word
43
Ia
A
word
44
Ib
A
word
45
Ic
A
word
46
Pa
 
word
47
Pb
 
word
48
Pc
 
word
49
P total
 
word
50
Qa
 
word
51
Qb
 
word
52
Qc
 
word
53
Q total
 
word
54
Cosa
 
word
55
Cosb
 
word
56
Cosc
 
word
57
Cos total
 
word
58
Sa
 
word
59
Sb
 
word
60
Sc
 
word
61
S total
 
word
62
Frequency F
 
word
63
Measued im kwh
 
dword
65
Measued export kwh
 
dword
67
Measued import kvarh
 
dword
69
Measued export kvarh
 
dword
71
Real import kwh
 
single
73
Real export kwh
 
single
75
Real import kvarh
 
single
77
Real export kvarh
 
single

Acrel (PZ80) - MODBUS Registers Map

MODBUS offset
Description
Units
Data type
0
Voltage (effective value)
V
word
1
Voltage (index)
 
word
2
Current (effective value)
A
word
3
Current (index)
 
word
4
Frequency (effective value)
Hz
word
5
Frequency (index)
 
word
6
Power factor (effective value)
 
word
7
Power factor (index)
 
word
8
Active power (effective value)
W
word
9
Active power (index)
 
word
10
Reactive power (effective value)
var
word
11
Reactive power (index)
 
word
12
Active energy
Wh
dword
14
Reactive energy
varh
dword
16
Pt ratio (pt)
 
word
17
Ct ratio (ct)
 
word
18
Alarm and I/O
 
word

Related MODBUS registers maps