Afore - MODBUS Registers Map - Data Logging
The data can be automatically logged 24/7 into a database, CSV files, or Excel spreadsheets using the Advanced Serial Data Logger (for MODBUS RTU) or Advanced TCP/IP Data Logger (for MODBUS TCP) software. These data logging tools provide continuous and reliable Afore modbus logging and poll.
Do you not know the meter address? Scan the device address online
Afore (BNT) - MODBUS Registers Map
MODBUS offset
Description
Units
Data type
0
State bits
word
1
AB line voltage
V
word
2
BC line voltage
V
word
3
CA line voltage
V
word
4
A phase current
A
word
5
B phase current
A
word
6
C phase current
A
word
7
PVI voltage
V
word
8
PVI electric current
A
word
9
PV2 voltage
V
word
10
PV2 electric current
A
word
11
PV3 voltage
V
word
12
PV3 electric current
A
word
13
Grid frequency
HZ
word
14
Module temperature
C
word
15
Inverter housing temperature
C
word
16
Generation day
W
dword
18
Current generation power
W
dword
20
The cumulative generation time of
second
dword
22
Current cumulative power generation
W
dword
24
Error bits 1
word
25
Error bits 2
word
26
Error bits 3
word
27
Error bits 4
word
28
Error bits 5
word