Microstar Electric - MODBUS Registers Map - Data Logging
The data can be automatically logged 24/7 into a database, CSV files, or Excel spreadsheets using the Advanced Serial Data Logger (for MODBUS RTU) or Advanced TCP/IP Data Logger (for MODBUS TCP) software. These data logging tools provide continuous and reliable Microstar Electric data logging and log.
Do you not know the meter address? Scan the device address online
Microstar Electric (PT 2000) - MODBUS Registers Map
MODBUS offset
Description
Units
Data type
32784
Total import active energy
kWh
single
32786
Tariff 1 import active energy
kWh
single
32788
Tariff 2 import active energy
kWh
single
32790
Tariff 3 import active energy
kWh
single
32792
Tariff 4 import active energy
kWh
single
32800
Total export active energy
kWh
single
32802
Tariff 1 export active energy
kWh
single
32804
Tariff 2 export active energy
kWh
single
32806
Tariff 3 export active energy
kWh
single
32808
Tariff 4 export active energy
kWh
single
33040
Total import reactive energy
kvarh
single
33042
Tariff 1 import reactive energy
kvarh
single
33044
Tariff 2 import reactive energy
kvarh
single
33046
Tariff 3 import reactive energy
kvarh
single
33048
Tariff 4 import reactive energy
kvarh
single
33056
Total export reactive energy
kvarh
single
33058
Tariff 1 export reactive energy
kvarh
single
33060
Tariff 2 export reactive energy
kvarh
single
33062
Tariff 3 export reactive energy
kvarh
single
33064
Tariff 4 export reactive energy
kvarh
single
42514
Phase A voltage
V
dword
42516
Phase B voltage
V
dword
42518
Phase C voltage
V
dword
42530
Phase A current
A
dword
42532
Phase B current
A
dword
42534
Phase C current
A
dword
42544
Total active power
kW
dword
42546
Phase A active power
kW
dword
42548
Phase B active power
kW
dword
42550
Phase C active power
kW
dword
42560
Total reactive power
kvar
dword
42562
Phase A reactive power
kvar
dword
42564
Phase B reactive power
kvar
dword
42566
Phase C reactive power
kvar
dword
42592
Total apparent power
kVA
dword
42594
Phase A apparent power
kVA
dword
42596
Phase B apparent power
kVA
dword
42598
Phase C apparent power
kVA
dword
42576
Total power factor
dword
42578
Phase A power factor
dword
42580
Phase B power factor
dword
42582
Phase C power factor
dword
42608
Frequency
word