Mennekes (AMTRON HCC3) - MODBUS Registers
MODBUS offset
Description
Units
Data type
768
HMI temperature internal
smallint
769
HMI temperature external
smallint
770
CP state
word
771
PP state
word
772
HCC3 error code
word
773
State
word
774
Operation mode
A
word
775
Connector type
word
776
No. of phases
word
777
Rated current
A
word
778
Installation current
A
word
779
Serial number
dword
781
Charging session meter count
Wh
dword
783
Actual power con- sumption
W
dword
785
Wallbox name
string
787
Max current T1
A
word
788
Start hour T1
word
789
Start minute T1
word
790
Price T1
word
792
Start hour T2
word
793
Start minute T2
word
794
Price T2
word
795
Planned min cur- rent
A
word
796
Planned max cur- rent
A
word
797
Planned min power
W
word
798
Planned max power
W
word
Related MODBUS registers maps