SolarEdge SE5000H, SE5K, SE6000H MODBUS registers: read online

Connect SolarEdge to the computer through a USB-to-serial or RS485 adapter and read its registers in your browser: click "Read register values online" under the model (Chrome or Edge, nothing to install). The tables below list the MODBUS offset, unit, data type and scale of every register shown. For logging 24/7 into a database, CSV files or Excel, use the Advanced Serial Data Logger (for MODBUS RTU) or Advanced TCP/IP Data Logger (for MODBUS TCP): they poll the complete map of every model on this page and provide continuous SolarEdge modbus logging and log.

Do you not know the meter address? Scan the device address online

SolarEdge (SE5000H) - MODBUS Mapping

Registers in the map: 43. function 3 (holding registers). byte order big-endian. data types: dword, smallint, word.

MODBUS offsetDescriptionUnitsData typeScale
40069AC CurrentAword×10A_SF
40070Phase A CurrentAword×10A_SF
40071Phase B CurrentAword×10A_SF
40072Phase C CurrentAword×10A_SF
40073Scale factor [A_SF] smallint 
40074Phase Voltage ABVword×10V_SF
40075Phase Voltage BCVword×10V_SF
40076Phase Voltage CAVword×10V_SF
40077Phase Voltage ANVword×10V_SF
40078Phase Voltage BNVword×10V_SF
40079Phase Voltage CNVword×10V_SF
40080Scale factor [V_SF] smallint 
40081AC PowerWsmallint×10W_SF
40082Scale factor [W_SF] smallint 
40083Line FrequencyHzword×10HZ_SF
40084Scale factor [HZ_SF] smallint 
40085AC Apparent PowerVAsmallint×10VA_SF
40086Scale factor [VA_SF] smallint 
40087AC Reactive Powervarsmallint×10VAR_SF
40088Scale factor [VAR_SF] smallint 
40089AC Power Factor%smallint×10PF_SF
40090Scale factor [PF_SF] smallint 
40091AC EnergyWhdword×10WH_SF
40093Scale factor [WH_SF] smallint 
40094DC CurrentAword×10DCA_SF
40095Scale factor [DCA_SF] smallint 
40096DC VoltageVword×10DCV_SF
40097Scale factor [DCV_SF] smallint 
40098DC PowerWsmallint×10DCW_SF
40099Scale factor [DCW_SF] smallint 
40100Cabinet Temperaturedeg Csmallint×10TMP_SF
40101Heat Sink Temperaturedeg Csmallint×10TMP_SF
40102Transformer Temperaturedeg Csmallint×10TMP_SF
40103Other Temperaturedeg Csmallint×10TMP_SF
40104Scale factor [TMP_SF] smallint 
40105Enumerated value. Operating state word 
40106Vendor specific operating state code word 
40107Bitmask value. Event fields dword 
40109Reserved for future use dword 
40111Vendor defined events dword 
40113Vendor defined events dword 
40115Vendor defined events dword 
40117Vendor defined events dword 

SolarEdge (SE5000) - MODBUS Measurements

Registers in the map: 122 (the first 50 are listed below; the browser reader and the data loggers use the complete map). function 3 (holding registers). byte order big-endian. data types: dword, smallint, utf8(16), utf8(32), word.

MODBUS offsetDescriptionUnitsData typeScale
40069AC CurrentAword×10A_SF
40070Phase A CurrentAword×10A_SF
40071Phase B CurrentAword×10A_SF
40072Phase C CurrentAword×10A_SF
40073Scale factor [A_SF] smallint 
40074Phase Voltage ABVword×10V_SF
40075Phase Voltage BCVword×10V_SF
40076Phase Voltage CAVword×10V_SF
40077Phase Voltage ANVword×10V_SF
40078Phase Voltage BNVword×10V_SF
40079Phase Voltage CNVword×10V_SF
40080Scale factor [V_SF] smallint 
40081AC PowerWsmallint×10W_SF
40082Scale factor [W_SF] smallint 
40083Line FrequencyHzword×10HZ_SF
40084Scale factor [HZ_SF] smallint 
40085AC Apparent PowerVAsmallint×10VA_SF
40086Scale factor [VA_SF] smallint 
40087AC Reactive Powervarsmallint×10VAR_SF
40088Scale factor [VAR_SF] smallint 
40089AC Power Factor%smallint×10PF_SF
40090Scale factor [PF_SF] smallint 
40091AC EnergyWhdword×10WH_SF
40093Scale factor [WH_SF] smallint 
40094DC CurrentAword×10DCA_SF
40095Scale factor [DCA_SF] smallint 
40096DC VoltageVword×10DCV_SF
40097Scale factor [DCV_SF] smallint 
40098DC PowerWsmallint×10DCW_SF
40099Scale factor [DCW_SF] smallint 
40100Cabinet Temperaturedeg Csmallint×10TMP_SF
40101Heat Sink Temperaturedeg Csmallint×10TMP_SF
40102Transformer Temperaturedeg Csmallint×10TMP_SF
40103Other Temperaturedeg Csmallint×10TMP_SF
40104Scale factor [TMP_SF] smallint 
40105Enumerated value. Operating state word 
40106Vendor specific operating state code word 
40107Bitmask value. Event fields dword 
40109Reserved for future use dword 
40111Vendor defined events dword 
40113Vendor defined events dword 
40115Vendor defined events dword 
40117Vendor defined events dword 
40121Well known value registered with SunSpec for compliance utf8(32) 
40137Manufacturer specific value (32 chars) utf8(32) 
40153Manufacturer specific value (16 chars) utf8(16) 
40161Manufacturer specific value (16 chars) utf8(16) 
40169Manufacturer specific value (32 chars) utf8(32) 
40185Modbus device address word 
40186Force even alignment  

This is not the complete map: 50 of 122 registers are listed above. Click "Read register values online" to read any register of your device in the browser, or download the program to log the complete map.

SolarEdge (SE5K) - MODBUS Maps

Registers in the map: 43. function 3 (holding registers). byte order big-endian. data types: dword, smallint, word.

MODBUS offsetDescriptionUnitsData typeScale
40069AC CurrentAword×10A_SF
40070Phase A CurrentAword×10A_SF
40071Phase B CurrentAword×10A_SF
40072Phase C CurrentAword×10A_SF
40073Scale factor [A_SF] smallint 
40074Phase Voltage ABVword×10V_SF
40075Phase Voltage BCVword×10V_SF
40076Phase Voltage CAVword×10V_SF
40077Phase Voltage ANVword×10V_SF
40078Phase Voltage BNVword×10V_SF
40079Phase Voltage CNVword×10V_SF
40080Scale factor [V_SF] smallint 
40081AC PowerWsmallint×10W_SF
40082Scale factor [W_SF] smallint 
40083Line FrequencyHzword×10HZ_SF
40084Scale factor [HZ_SF] smallint 
40085AC Apparent PowerVAsmallint×10VA_SF
40086Scale factor [VA_SF] smallint 
40087AC Reactive Powervarsmallint×10VAR_SF
40088Scale factor [VAR_SF] smallint 
40089AC Power Factor%smallint×10PF_SF
40090Scale factor [PF_SF] smallint 
40091AC EnergyWhdword×10WH_SF
40093Scale factor [WH_SF] smallint 
40094DC CurrentAword×10DCA_SF
40095Scale factor [DCA_SF] smallint 
40096DC VoltageVword×10DCV_SF
40097Scale factor [DCV_SF] smallint 
40098DC PowerWsmallint×10DCW_SF
40099Scale factor [DCW_SF] smallint 
40100Cabinet Temperaturedeg Csmallint×10TMP_SF
40101Heat Sink Temperaturedeg Csmallint×10TMP_SF
40102Transformer Temperaturedeg Csmallint×10TMP_SF
40103Other Temperaturedeg Csmallint×10TMP_SF
40104Scale factor [TMP_SF] smallint 
40105Enumerated value. Operating state word 
40106Vendor specific operating state code word 
40107Bitmask value. Event fields dword 
40109Reserved for future use dword 
40111Vendor defined events dword 
40113Vendor defined events dword 
40115Vendor defined events dword 
40117Vendor defined events dword 

SolarEdge (SE6000H) - MODBUS Values

Registers in the map: 122 (the first 50 are listed below; the browser reader and the data loggers use the complete map). function 3 (holding registers). byte order big-endian. data types: dword, smallint, utf8(16), utf8(32), word.

MODBUS offsetDescriptionUnitsData typeScale
40069AC CurrentAword×10A_SF
40070Phase A CurrentAword×10A_SF
40071Phase B CurrentAword×10A_SF
40072Phase C CurrentAword×10A_SF
40073Scale factor [A_SF] smallint 
40074Phase Voltage ABVword×10V_SF
40075Phase Voltage BCVword×10V_SF
40076Phase Voltage CAVword×10V_SF
40077Phase Voltage ANVword×10V_SF
40078Phase Voltage BNVword×10V_SF
40079Phase Voltage CNVword×10V_SF
40080Scale factor [V_SF] smallint 
40081AC PowerWsmallint×10W_SF
40082Scale factor [W_SF] smallint 
40083Line FrequencyHzword×10HZ_SF
40084Scale factor [HZ_SF] smallint 
40085AC Apparent PowerVAsmallint×10VA_SF
40086Scale factor [VA_SF] smallint 
40087AC Reactive Powervarsmallint×10VAR_SF
40088Scale factor [VAR_SF] smallint 
40089AC Power Factor%smallint×10PF_SF
40090Scale factor [PF_SF] smallint 
40091AC EnergyWhdword×10WH_SF
40093Scale factor [WH_SF] smallint 
40094DC CurrentAword×10DCA_SF
40095Scale factor [DCA_SF] smallint 
40096DC VoltageVword×10DCV_SF
40097Scale factor [DCV_SF] smallint 
40098DC PowerWsmallint×10DCW_SF
40099Scale factor [DCW_SF] smallint 
40100Cabinet Temperaturedeg Csmallint×10TMP_SF
40101Heat Sink Temperaturedeg Csmallint×10TMP_SF
40102Transformer Temperaturedeg Csmallint×10TMP_SF
40103Other Temperaturedeg Csmallint×10TMP_SF
40104Scale factor [TMP_SF] smallint 
40105Enumerated value. Operating state word 
40106Vendor specific operating state code word 
40107Bitmask value. Event fields dword 
40109Reserved for future use dword 
40111Vendor defined events dword 
40113Vendor defined events dword 
40115Vendor defined events dword 
40117Vendor defined events dword 
40121Well known value registered with SunSpec for compliance utf8(32) 
40137Manufacturer specific value (32 chars) utf8(32) 
40153Manufacturer specific value (16 chars) utf8(16) 
40161Manufacturer specific value (16 chars) utf8(16) 
40169Manufacturer specific value (32 chars) utf8(32) 
40185Modbus device address word 
40186Force even alignment  

This is not the complete map: 50 of 122 registers are listed above. Click "Read register values online" to read any register of your device in the browser, or download the program to log the complete map.