ABB (Trio 50,Trio 60) data logging. MODBUS registers map.


This data is being extracted with the help of the Advanced Serial Data Logger (MODBUS RTU,ASCII) or Advanced TCP/IP Data Logger (MODBUS TCP) software only. It may not applicable for other software titles.

MODBUS offsetDescriptionUnitsData type
1000Inverter ID word
1001Inverter block modbus map size word
1002Inverter presence word
1050Global state word
1051Alarm state word
1052DC/DC converter state word
1053DC/AC converter state word
1054Derating state word
1070Daily energyWhdword
1072Total energyWhdword
1074Partial energyWhdword
1076Weekly energyWhdword
1078Monthly energyWhdword
1080Yearly energyWhdword
1090Mean grid voltage (Phase to neutral)Vsingle
1092Mean output current (Phase to neutral)Asingle
1094Output active power: instantaneousWsingle
1096Output active power: absolute peakWsingle
1098Output active power: daily peakWsingle
1100Output active power: feedback on curtailment appliedWsingle
1102Reactive power: feedback on set point appliedVArsingle
1104Power factor: feedback on set point applied single
1106Mean grid frequencyHzsingle
1108Active power on DC input #1Wsingle
1110Voltage on DC input #1Vsingle
1112Current on DC input #1Asingle
1120Internal temperaturedegCsingle
1122Inverter temperaturedegCsingle
1126Isolation resistanceMOhmsingle
1128Max leakage currentAsingle
3654Build version word