Accuenergy (AcuRev 1300) data logging. MODBUS registers map.


This data is being extracted with the help of the Advanced Serial Data Logger (MODBUS RTU,ASCII) or Advanced TCP/IP Data Logger (MODBUS TCP) software only. It may not applicable for other software titles.

MODBUS offsetDescriptionUnitsData type
4132Options string(16)
4140Version string(16)
4148Serial number string(12)
4164Device address word
4165Id word
4166Lenth word
4167Amps (total): sunspec; total current: acurev 1300 smallint
4168Amps phase a: sunspec; phase A current: acurev 1300 smallint
4169Amps phase b: sunspec; phase B current: acurev 1300 smallint
4170Amps phase c: sunspec; phase C current: acurev 1300 smallint
4172Voltage ln (average): sunspec; phase average voltage: acurev 1300 smallint
4173Phase voltage an: sunspec; phase A voltage: acurev 1300 smallint
4174Phase voltage bn: sunspec; phase B voltage: acurev 1300 smallint
4175Phase voltage cn: sunspec; phase C voltage: acurev 1300 smallint
4176Voltage ll (average): sunspec; line average voltage: acurev 1300 smallint
4177Phase voltage ab: sunspec; line ab voltage: acurev 1300 smallint
4178Phase voltage bc: sunspec; line bc voltage: acurev 1300 smallint
4179Phase voltage ca: sunspec; line ca voltage: acurev 1300 smallint
4181Frequency smallint
4183Total real power: sunspec; total active power: acurev 1300 smallint
4184Watts phase a: sunspec; phase A active power: acurev 1300 smallint
4185Watts phase b: sunspec; phase B active power: acurev 1300 smallint
4186Watts phase c: sunspec; phase C active power: acurev 1300 smallint
4188Ac apparent power va: sunspec; total apparent power: acurev 1300 smallint
4189Va phase a: sunspec; phase A apparent power: acurev 1300 smallint
4190Va phase b: sunspec; phase B apparent power: acurev 1300 smallint
4191Va phaseca: sunspec; phase C apparent power: acurev 1300 smallint
4193Reactive power var: sunspec; total reactive power: acurev 1300 smallint
4194Var phase a: sunspec; phase A reactive power: acurev 1300 smallint
41954195 var phase b: sunspec; phase B reactive power: acurev 1300 smallint
4196Var phase c: sunspec; phase C reactive power: acurev 1300 smallint
4198Power factor smallint
4199Pf phase A smallint
4200Pf phase B smallint
4201Pf phase C smallint
4203Total real energy exported: sunspec total active energy exported: acurev 1300 single
4205Total watt hours exported in phase a: sunspec; total active energy exported in phase a: acurev 1300 single
4207Total watt hours exported in phase b: sunspec; total active energy exported in phase b: acurev 1300 single
4209Total watt hours exported in phase c: sunspec; total active energy exported in phase c: acurev 1300 single
4211Total real energy imported: sunspec; total active energy imported: acurev 1300 single
4213Total watt hours imported phase a: sunspec; total active energy imported in phase a: acurev 1300 single
4215Total watt hours imported phase b: sunspec; total active energy imported in phase b: acurev 1300 single
4217Total watt hours imported phase c: sunspec; total active energy imported in phase c: acurev 1300 single
4220Total va hours exported: sunspec; total apparent power exported: acurev 1300 single
4222Total va hours exported phase a: sunspec; total apparent power exported in phase a: acurev 1300 single
4224Total va hours exported phase b: sunspec; total apparent power exported in phase b: acurev 1300 single
4226Total va hours exported phase c: sunspec; total apparent power exported in phase c: acurev 1300 single
4228Total va hours imported: sunspec; total apparent power imported: acurev 1300 single
4230Total va hours imported phase a: sunspec; total apparent power imported in phase a: acurev 1300 single
4232Total va hours imported phase b: sunspec; total apparent power imported in phase b: acurev 1300 single
There are more MODBUS items for this device. Please, download the program.

Note: Products and companies mentioned here are used only for definition and identification purposes and can be trademarks and/or registered trademarks of the respective companies.