Epever (B Series) data logger. MODBUS registers map.


This data is being extracted with help of the Advanced Serial Data Logger (MODBUS RTU,ASCII) or Advanced TCP/IP Data Logger (MODBUS TCP) software only. It may not applicable for other software titles.

MODBUS offsetDescriptionUnitsData type
12288Array rated voltageVword
12289Array rated currentAword
12290Array rated powerWdword
12292Battery rated voltageVword
12293Battery rated currentAword
12294Battery rated powerWdword
12296Charging mode word
12302Rated current of loadWword
12544Pv array input voltageVword
12545Pv array input currentAword
12546Pv array input powerWdword
12550Battery powerWdword
12556Load voltageVword
12557Load currentAword
12558Load powerWdword
12560Battery temperatureCword
12561Temperature inside equipmentCword
12570Battery soc word
12571Remote battery temperature,word
12573Battery's real rated powerCword
12800Battery status word
12801Charging equipment status word
12802Discharging equipment status word
13056Maximum pv voltage todayVword
13057Minimum pv voltage todayVword
13058Maximum battery voltage todayVword
13059Minimum battery voltage todayVword
13060Consumed energy today dword
13062Consumed energy this month dword
13064Consumed energy this year dword
13066Total consumed energy dword
13068Generated energy today dword
13070Generated energy this month dword
13072Generated energy this year dword
13074Total generated energyKWHdword
13082Battery voltageVword