MODBUS offsetDescriptionUnitsData type
40215Hours: format hhmmss smallint
40217Data format aammgg smallint
40219Meter serial number (read by dlms) smallint
40221Reset meter count single
40223Total active energy a+ single
40225Total active energy previous month A + single
40227Total active energy slot 1 a+ single
40229Total active energy slot 1 previous month A + single
40231Total active energy slot 2 a+ single
40233Total active energy slot 2 previous month A + single
40235Total active energy slot 3 a+ single
40237Total active energy slot 3 previous month A + single
40239Total active energy slot 4 a+ single
40241Total active energy slot 4 previous month A + single
40243Total active energy A single
40245Total active energy previous month A single
40247Total active energy slot 1 A single
40249Total active energy slot 1 previous month A single
40251Total active energy slot 2 A single
40253Total active energy slot 2 previous month A single
40255Total active energy slot 3 A single
40257Total active energy slot 3 previous month A single
40259Total active energy slot 4 A single
40261Total active energy slot 4 previous month A single
40263Reactive total energy Q1 single
40265Reactive total energy previous month Q1 single
40267Reactive total energy slot 1 Q1 single
40269Reactive total energy slot 1 previous month Q1 single
40271Reactive total energy slot 2 Q1 single
40273Reactive total energy slot 2 previous month Q1 single
40275Reactive total energy slot 3 Q1 single
40277Reactive total energy slot 3 previous month Q1 single
40279Reactive total energy slot 4 Q1 single
40281Reactive total energy slot 4 previous month Q1 single
40283Reactive total energy Q2 single
40285Reactive total energy previous month Q2 single
40287Reactive total energy slot 1 Q2 single
40289Reactive total energy slot 1 previous month Q2 single
40291Reactive total energy slot 2 Q2 single
40293Reactive total energy slot 2 previous month Q2 single
40295Reactive total energy slot 3 Q2 single
40297Reactive total energy slot 3 previous month Q2 single
40299Reactive total energy slot 4 Q2 single
40301Reactive total energy slot 4 previous month Q2 single
40303Reactive total energy Q3 single
40305Reactive total energy previous month Q3 single
40307Reactive total energy slot 1 Q3 single
40309Reactive total energy slot 1 previous month Q3 single
40311Reactive total energy slot 2 Q3 single
40313Reactive total energy slot 2 previous month Q3 single
40315Reactive total energy slot 3 Q3 single
40317Reactive total energy slot 3 previous month Q3 single
40319Reactive total energy slot 4 Q3 single
40321Reactive total energy slot 4 previous month Q3 single
40323Reactive total energy Q4 single
40325Reactive total energy previous month Q4 single
40327Reactive total energy slot 1 Q4 single
40329Reactive total energy slot 1 previous month Q4 single
40331Reactive total energy slot 2 Q4 single
40333Reactive total energy slot 2 previous month Q4 single
40335Reactive total energy slot 3 Q4 single
40337Reactive total energy slot 3 previous month Q4 single
40339Reactive total energy slot 4 Q4 single
40341Reactive total energy slot 4 previous month Q4 single
40343Power max slot 1 A + single
40345Power max slot 1 previous month A + single
40347Power max slot 2 A + single
40349Power max slot 2 previous month A + single
40351Power max slot 3 A + single
40353Power max slot 3 previous month A + single
40355Power max slot 4 A + single
40357Power max slot 4 previous month A + single
40359Power max slot 1 A single
40361Power max slot 1 previous month A single
40363Power max slot 2 A single
40365Power max slot 2 previous month A single
40367Power max slot 3 A single
40369Power max slot 3 previous month A single
40371Power max slot 4 A single
40373Power max slot 4 previous month A single
40375Internal signal control status single
40377Internal operation status single
40379Voltage phase 1 single
40381Voltage phase 2 single
40383Voltage phase 3 single
40385Power failure counter phase1 single
40387Power failure counter phase2 single
40389Power failure counter phase3 single
40391Power failure total counter for phase 1,2,3 single
40393Overvoltage event number phase1 single
40395Overvoltage event number phase2 single
40397Overvoltage event number phase3 single
40399Current L1 single
40401Current L2 single
40403Current L3 single
40405Frequency single
40407Reactive imported energy single
40409Reactive imported energy previous month single
40411Reactive exported energy single
40413Reactive exported energy previous month single
There are more MODBUS items for this device. Please, download the program.