Masibus PM2160-3P3W, PM2160-3P4W MODBUS registers: read online

Connect Masibus to the computer through a USB-to-serial or RS485 adapter and read its registers in your browser: click "Read register values online" under the model (Chrome or Edge, nothing to install). The tables below list the MODBUS offset, unit, data type and scale of every register shown. For logging 24/7 into a database, CSV files or Excel, use the Advanced Serial Data Logger (for MODBUS RTU) or Advanced TCP/IP Data Logger (for MODBUS TCP): they poll the complete map of every model on this page and provide continuous Masibus data logger and record.

Do you not know the meter address? Scan the device address online

Masibus (PM2160-3P3W) - MODBUS Measurements

Connection and addressing notes

Protocol
Modbus
Function code
04 read input registers
Message ending
CRC
Register blocks
30001 to 30121, 32001 to 32033, 30150 to 30154, 30200 to 30294, 30301 to 30311
Data word count
multiples of 2, all values are 4 bytes (long or real)
2-byte block values
decimal

Registers in the map: 99 (the first 50 are listed below; the browser reader and the data loggers use the complete map). function 4 (input registers). byte order big-endian. data types: dword.

MODBUS offsetDescriptionUnitsData typeScale
0Frequency dword×0.01
21 2. Pf dword×0.001
63 2. Pf dword×0.001
8A. Pf dword×0.001
10Vrms 12 dword 
12Vrms 3*1 dword 
14Vrms 2*3 dword 
16A vrms dword 
241. Irms dword×0.001
283. Irms dword×0.001
30A. Irms dword×0.001
341 2.Wdword 
383 2.Wdword 
40S.Wdword 
421 2.vardword 
463 2.vardword 
48S.vardword 
501 2.VAdword 
543 2.VAdword 
56S.VAdword 
581 2. Wh import dword×0.1
623 2. Wh import dword×0.1
64T. Wh import dword 
661 2. Wh export dword 
703 2. Wh export dword 
72T. Wh export dword 
741 2. Varh import dword 
783 2. Varh import dword 
80T. Varh import dword 
821 2. Varh export dword 
863 2. Varh export dword 
88T. Varh export dword 
901 2. Vah dword 
943 2. Vah dword 
96T. Vah dword 
98Rising demand dword 
100Real date dword 
102Real time dword 
104Maximum demand dword×0.1
106Md date dword 
108Md time dword 
1101 2. Phase angle dword×0.01
1143 2. Phase angle dword×0.01
116V. Unbalance dword×0.01
1181. Unbalance dword 
2000Frequency dword×2
20021. Vrms dword×2
20042. Vrms dword×2
20063. Vrms dword×2
2008A. Vrms dword×2

This is not the complete map: 50 of 99 registers are listed above. Click "Read register values online" to read any register of your device in the browser, or download the program to log the complete map.

Masibus (PM2160-3P4W) - MODBUS Mapping

Connection and addressing notes

Protocol
Modbus RTU
Interface
RS-485
RTU encoding
each 8-bit byte carries two 4-bit hexadecimal characters
Function codes
03 read holding registers, 04 read input registers, 06 preset single register
Register blocks
30001 to 30121, 30150 to 30154, 30200 to 30294
Word count
must be even for the 4-byte long/real blocks
Message ending
CRC

Registers in the map: 112 (the first 50 are listed below; the browser reader and the data loggers use the complete map). function 4 (input registers). byte order big-endian. data types: dword.

MODBUS offsetDescriptionUnitsData typeScale
0Frequency dword×0.01
21. Pf dword×0.001
42. Pf dword×0.001
63. Pf dword×0.001
8A. Pf dword×0.001
101. Vrms dword×0.1
122. Vrms dword×0.1
143. Vrms dword×0.1
16A. Vrms dword×0.1
18Vrms 1*2 dword×0.1
20Vrms 2*3 dword×0.1
22Vrms 31 dword×0.1
241. Irms dword×0.001
262. Irms dword×0.001
283. Irms dword×0.001
30A. Irms dword×0.001
341.Wdword 
362.Wdword 
383.Wdword 
40S.Wdword 
421.vardword 
442.var dword 
463.var dword 
48S.var dword 
501.va dword 
522.va dword 
543.va dword 
56S.va dword 
581.wh import dword×0.1
602.wh import dword×0.1
623.wh import dword×0.1
64T.wh import dword×0.1
661.wh export dword×0.1
682.wh export dword×0.1
703.wh export dword×0.1
72T.wh export dword×0.1
741. Varh import dword×0.1
762. Varh import dword×0.1
783. Varh import dword×0.1
80T. Varh import dword×0.1
821. Varh export dword×0.1
842. Varh export dword×0.1
863. Varh export dword×0.1
88T. Varh export dword×0.1
901.vah dword×0.1
922.vah dword×0.1
943.vah dword×0.1
96T.vah dword×0.1
98Rising demand dword×0.1
100Real date dword 

This is not the complete map: 50 of 112 registers are listed above. Click "Read register values online" to read any register of your device in the browser, or download the program to log the complete map.

Related MODBUS registers maps

Note: Products and companies mentioned here are used only for definition and identification purposes and can be trademarks and/or registered trademarks of the respective companies.

MODBUS COM Port Connection