Secure (Elite 440) logging. MODBUS registers map.
This data is being extracted with the help of the Advanced Serial Data Logger (MODBUS RTU,ASCII) or Advanced TCP/IP Data Logger (MODBUS TCP) software only. It may not applicable for other software titles.
MODBUS offset | Description | Units | Data type |
99 | Phase to neutral voltage (V1) | Volt | single |
101 | Phase to neutral voltage (V2) | Volt | single |
103 | Phase to neutral voltage (V3) | Volt | single |
105 | Average voltage | Volt | single |
107 | Voltage (v12) | Volt | single |
109 | Voltage (v23) | Volt | single |
111 | Voltage (v31) | Volt | single |
113 | Phase line current (L1) | Ampere | single |
115 | Phase line current (L2) | Ampere | single |
117 | Phase line current (L3) | Ampere | single |
119 | Neutral line current (ln) | Ampere | single |
121 | Phase active current (I1) | Ampere | single |
123 | Phase active current (I2) | Ampere | single |
125 | Phase active current (I3) | Ampere | single |
127 | Phase reactive current (R1) | Ampere | single |
129 | Phase reactive current (R2) | Ampere | single |
131 | Phase reactive current (R3) | Ampere | single |
133 | Power factor (Q1) | | single |
135 | Power factor (Q2) | | single |
137 | Power factor (Q3) | | single |
139 | Avg power factor (qa) | | single |
141 | Phase active power (kt1) | kW | single |
143 | Phase active power (kt2) | kW | single |
145 | Phase active power (kt3) | kW | single |
147 | Phase active power (kt) | KW | single |
149 | Phase reactive power (kv1) | kVAr | single |
151 | Phase reactive power (kv2) | kVAr | single |
153 | Phase reactive power (kv3) | kVAr | single |
155 | Phase reactive power (kv) | kVAr | single |
157 | Phase apparent power (ka1) | kVA | single |
159 | Phase apparent power (ka2) | kVA | single |
161 | Phase apparent power (ka3) | kVA | single |
163 | Phase apparent power (ka) | kVA | single |
165 | Ph ang (a12) | Degree | single |
167 | Ph ang (a23) | Degree | single |
169 | Ph ang (a31) | Degree | single |
171 | Frequency hz (fq) | Hz | single |
173 | Meter real time (rt) | Seconds | dword |
175 | Meter temperature | Degree Centi | single |
177 | R phase voltage total harmonic distortion | % | single |
179 | Y phase voltage total harmonic distortion | % | single |
181 | B phase voltage total harmonic distortion | % | single |
183 | R phase current total harmonic distortion | % | single |
185 | Y phase current total harmonic distortion | % | single |
187 | B phase current total harmonic distortion | % | single |
189 | R phase power total harmonic distortion | % | single |
191 | Y phase power total harmonic distortion | % | single |
193 | B phase power total harmonic distortion | % | single |
199 | Active total import | | single |
201 | Active total export | | single |
There are more MODBUS items for this device. Please, download the program. |