DNC and CNC setting for Okuma - Okuma T
These settings are for the DNC Precision software only. They may not work with other software.
Set the following parameters on the machine
1 (tape feed) | 1 |
34 (time before alarm) | 30 |
39 (baud rate) | 4800 |
44 (punch device) | 0 |
46 (output device) | 0 |
54 (read device) | 1 |
57 (time before alarm) | 90 |
Optional parameter bits #1 (ISO code) | 0000 1011 |
Optional parameter bits #2 | 0000 0000 |
Optional parameter bits #12 (stop bits, parity) | 1010 0010 |
Optional parameter bits #21 | 0000 0000 |
Set the following parameters on the PC
Serial port tab
Machine name | Okuma - Okuma T |
Serial port | COM2 (or any free COM port) |
Baud | 4800 |
Data bits | 7 |
Parity | Even |
Stop bits | 2 |
Data flow control tab
Use DTR | False |
Use RTS | True |
Require DSR | False |
Require CTS | True |
Set RTS | False |
Set DTR | False |
Software flowcontrol | None |
Xon char | #11 |
Xoff char | #13 |
Data exchange format tab
Format mode | Uniform |
Format parameters | Program start: %
Program end: %
Line start:
Line end: #0D#0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No |
Null modem cable, without handshake
PC, 9pin, DB9M | CNC, 25pin, DB25
Null modem cable, without handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
If you have successfully connected DNC Precision
with any other controller not in this list, we would appreciate your sending us the
details to add to the list.
Note: We are not responsible and do not provide guarantee for any of these
settings, that have been sent us by our customers.