Celsa - MODBUS Registers Map - Read & Log

The data can be automatically logged 24/7 into a database, CSV files, or Excel spreadsheets using the Advanced Serial Data Logger (for MODBUS RTU) or Advanced TCP/IP Data Logger (for MODBUS TCP) software. These data logging tools provide continuous and reliable Celsa logging and record.

Do you not know the meter address? Scan the device address online

Celsa (TNM 35,TNM 96,TNM 144,TNM 300) - Mapping

MODBUS offset
Description
Units
Data type
0
Voltage line 1
 
single
2
Voltage line 2
 
single
4
Voltage line 3
 
single
6
Voltage between line 1 and line 2
 
single
8
Voltage between line 2 and line 3
 
single
10
Voltage between line 3 and line L
 
single
12
Current in line 1
 
single
14
Current in line 2
 
single
16
Current in line 3
 
single
18
Active power line 1 (Watt)
 
single
20
Active power line 2 (Watt)
 
single
22
Active power line 3 watt)
 
single
24
Combined active power line 1+2+3 watt
 
single
26
Apparent power line 1 (VA)
 
single
30
Apparent power line 3 (VA)
 
single
32
Combined apparent power line 1+2+3
 
single
34
Reactive power line 1 (VAR)
 
single
36
Reactive power line 2 (VAR)
 
single
38
Reactive power line 3 (VAR)
 
single
40
Combined reactive power line 1+2+3
 
single
42
Power factor line 1 (PF)
 
single
44
Power factor line 2 (PF)
 
single
46
Power factor line 3 (PF)
 
single
48
Combined power factor for line 1+2+3
 
single
50
Frequency line 1 (Hz)
 
single
52
Frequency line 2 (Hz)
 
single
54
Frequency line 3 (Hz)
 
single
56
Current neutral line
 
single
58
Power factor line 1 (L + c)
 
single
60
Power factor line 2 (L + c)
 
single
62
Power factor line 3 (L + c)
 
single
64
Combined power factor for line 1+2+3 (L)
 
single
66
Total current in line 1+2+3
 
single
76
TOU (Taoz) rate
 
single
78
Active total energy (Wh)
 
single
80
Reactive total energy (VARh)
 
single
82
Apparent total energy (Vah)
 
single
84
Date time (Win format)
 
single
86
Time from 01.01.2000 in seconds
 
single
88
ADDRESS
 
single
90
BAUD RATE
 
single
92
PARITY
 
single
94
Current transformer ratio
 
single
96
Timed average voltage
 
single
98
Timed average current
 
single
100
Timed average power
 
single
102
Timed avaerge frequqncy
 
single
104
THD for volts line 1
 
single
106
THD for volts line 2
 
single
108
THD for volts line 3
 
single