Celsa TNM 35, TNM 96, TNM 144 MODBUS registers: read online

Connect Celsa to the computer through a USB-to-serial or RS485 adapter and read its registers in your browser: click "Read register values online" under the model (Chrome or Edge, nothing to install). The tables below list the MODBUS offset, unit, data type and scale of every register shown. For logging 24/7 into a database, CSV files or Excel, use the Advanced Serial Data Logger (for MODBUS RTU) or Advanced TCP/IP Data Logger (for MODBUS TCP): they poll the complete map of every model on this page and provide continuous Celsa logger and poll.

Do you not know the meter address? Scan the device address online

Celsa (TNM 35,TNM 96,TNM 144,TNM 300) - MODBUS Mapping

Connection and addressing notes

Protocol
Modbus
Interface
RS-485
Function 03
integer part of a value
Function 04
full IEEE 754 float in two registers
Write function codes
06, 16
Device address register
89-90
Baud rate register
91-92
Parity register
93-94
Configuration password register
191-192
RS-485 response delay register
579-580

Registers in the map: 325 (the first 50 are listed below; the browser reader and the data loggers use the complete map). function 4 (input registers). byte order big-endian. data types: single.

MODBUS offsetDescriptionUnitsData typeScale
84Date time (Win format) single 
86Time from 01.01.2000 in seconds single 
88ADDRESS single 
0Voltage line 1 single 
2Voltage line 2 single 
4Voltage line 3 single 
6Voltage between line 1 and line 2 single 
8Voltage between line 2 and line 3 single 
10Voltage between line 3 and line L single 
12Current in line 1 single 
14Current in line 2 single 
16Current in line 3 single 
18Active power line 1Wsingle 
20Active power line 2Wsingle 
22Active power line 3 watt) single 
24Combined active power line 1+2+3Wsingle 
26Apparent power line 1VAsingle 
30Apparent power line 3VAsingle 
32Combined apparent power line 1+2+3 single 
34Reactive power line 1varsingle 
36Reactive power line 2varsingle 
38Reactive power line 3varsingle 
40Combined reactive power line 1+2+3 single 
42Power factor line 1PFsingle 
44Power factor line 2PFsingle 
46Power factor line 3PFsingle 
48Combined power factor for line 1+2+3 single 
50Frequency line 1Hzsingle 
52Frequency line 2Hzsingle 
54Frequency line 3Hzsingle 
56Current neutral line single 
58Power factor line 1 (L + c) single 
60Power factor line 2 (L + c) single 
62Power factor line 3 (L + c) single 
64Combined power factor for line 1+2+3 (L) single 
66Total current in line 1+2+3 single 
76TOU (Taoz) rate single 
78Active total energyWhsingle 
80Reactive total energyvarhsingle 
82Apparent total energy (Vah) single 
94Current transformer ratio single 
96Timed average voltage single 
98Timed average current single 
100Timed average power single 
102Timed avaerge frequqncy single 
104THD for volts line 1 single 
106THD for volts line 2 single 
108THD for volts line 3 single 
110THD for current line 1 single 
112THD for current line 2 single 

This is not the complete map: 50 of 325 registers are listed above. Click "Read register values online" to read any register of your device in the browser, or download the program to log the complete map.