Connect Kael to the computer through a USB-to-serial or RS485 adapter and read its registers in your browser: click "Read register values online" under the model (Chrome or Edge, nothing to install). The tables below list the MODBUS offset, unit, data type and scale of every register shown.
For logging 24/7 into a database, CSV files or Excel, use the Advanced Serial Data Logger (for MODBUS RTU) or Advanced TCP/IP Data Logger (for MODBUS TCP): they poll the complete map of every model on this page and provide continuous Kael logging and read.
Registers in the map: 691 (the first 50 are listed below; the browser reader and the data loggers use the complete map). function 3 (holding registers). byte order big-endian. data types: datetime, double, dword, int64, single, smallint, word.
MODBUS offset
Description
Units
Data type
Scale
4092
RealTime date
datetime
formula
4095
VTRFWM
word
×0.1
4096
CTRF
word
4097
Device working informations
word
4098
Phase1 voltage TRMS value
word
×0.1
4099
Phase2 voltage TRMS value
word
×0.1
4100
Phase3 voltage TRMS value
word
×0.1
4101
Phase1 current TRMS value
word
×0.001
4102
Phase2 current TRMS value
word
×0.001
4103
Phase3 current TRMS value
word
×0.001
4104
Phase1 active power TRMS value
smallint
formula
4105
Phase2 active power TRMS value
smallint
formula
4106
Phase3 active power TRMS value
smallint
formula
4107
Phase1 reactive power TRMS value
smallint
formula
4108
Phase2 reactive power TRMS value
smallint
formula
4109
Phase3 reactive power TRMS value
smallint
formula
4110
Phase1 appeared power TRMS value
word
formula
4111
Phase2 appeared power TRMS value
word
formula
4112
Phase3 appeared power TRMS value
word
formula
4113
Phase1 CosFiValue
smallint
×0.001
4114
Phase2 CosFiValue
smallint
×0.001
4115
Phase3 CosFiValue
smallint
×0.001
4116
Sum CosFiValue
smallint
×0.001
4117
Phase1 PowerFactor
smallint
×0.001
4118
Phase2 PowerFactor
smallint
×0.001
4119
Phase3 PowerFactor
smallint
×0.001
4120
SUM PowerFactor
smallint
×0.001
4121
Total active power
smallint
formula
4122
Total positive ReactivePower (+q) (unsigned)
word
formula
4123
Total negative reactive power (-q) (unsigned)
word
formula
4124
Sum reactive power ((+q)-(-q))
smallint
formula
4125
Sum appeared power
word
formula
4126
Frequency
word
×0.1
4127
Phase order number of frequency supply phase
word
4133
Phase-current connection and error messages
word
4134
Voltage1 ZerocrossOver (Referance)(Everytime 0)
word
4135
Current1 ZeroCrossover (Angle value)(0-359)
word
4136
Voltage2 ZerocrossOver (Angle value)(0-359)
word
4137
Current2 ZeroCrossover (Angle value)(0-359)
word
4138
Voltage3 ZerocrossOver (Angle value)(0-359)
word
4139
Current3 ZeroCrossover (Angle value)(0-359)
word
4140
Phase 1-2 voltage
word
×0.1
4141
Phase 2-3 voltage
word
×0.1
4142
Phase 3-1 voltage
word
×0.1
4143
Notr current
word
×0.001
4144
Phase 1-2 current
word
×0.001
4145
Phase 2-3 current
word
×0.001
4146
Phase 3-1 current
word
×0.001
4147
Voltage unbalance
smallint
4148
Current unbalance
smallint
This is not the complete map: 50 of 691 registers are listed above. Click "Read register values online" to read any register of your device in the browser, or download the program to log the complete map.
Registers in the map: 812 (the first 50 are listed below; the browser reader and the data loggers use the complete map). function 3 (holding registers). byte order big-endian. data types: datetime, double, dword, int64, single, smallint, word.
MODBUS offset
Description
Units
Data type
Scale
4092
RealTime date
datetime
formula
4095
VTRFWM
word
×0.1
4096
CTRF
word
4097
Device working informations
word
4098
Phase1 voltage TRMS value
word
×0.1
4099
Phase2 voltage TRMS value
word
×0.1
4100
Phase3 voltage TRMS value
word
×0.1
4101
Phase1 current TRMS value
word
×0.001
4102
Phase2 current TRMS value
word
×0.001
4103
Phase3 current TRMS value
word
×0.001
4104
Phase1 active power TRMS value
smallint
formula
4105
Phase2 active power TRMS value
smallint
formula
4106
Phase3 active power TRMS value
smallint
formula
4107
Phase1 reactive power TRMS value
smallint
formula
4108
Phase2 reactive power TRMS value
smallint
formula
4109
Phase3 reactive power TRMS value
smallint
formula
4110
Phase1 appeared power TRMS value
word
formula
4111
Phase2 appeared power TRMS value
word
formula
4112
Phase3 appeared power TRMS value
word
formula
4113
Phase1 CosFiValue
smallint
×0.001
4114
Phase2 CosFiValue
smallint
×0.001
4115
Phase3 CosFiValue
smallint
×0.001
4116
Sum CosFiValue
smallint
×0.001
4117
Phase1 PowerFactor
smallint
×0.001
4118
Phase2 PowerFactor
smallint
×0.001
4119
Phase3 PowerFactor
smallint
×0.001
4120
SUM PowerFactor
smallint
×0.001
4121
Total active power
smallint
formula
4122
Total positive ReactivePower (+q) (unsigned)
word
formula
4123
Total negative reactive power (-q) (unsigned)
word
formula
4124
Sum reactive power ((+q)-(-q))
smallint
formula
4125
Sum appeared power
word
formula
4126
Frequency
word
×0.1
4127
Phase order number of frequency supply phase
word
4133
Phase-current connection and error messages
word
4134
Voltage1 ZerocrossOver (Referance)(Everytime 0)
word
4135
Current1 ZeroCrossover (Angle value)(0-359)
word
4136
Voltage2 ZerocrossOver (Angle value)(0-359)
word
4137
Current2 ZeroCrossover (Angle value)(0-359)
word
4138
Voltage3 ZerocrossOver (Angle value)(0-359)
word
4139
Current3 ZeroCrossover (Angle value)(0-359)
word
4140
Phase 1-2 voltage
word
×0.1
4141
Phase 2-3 voltage
word
×0.1
4142
Phase 3-1 voltage
word
×0.1
4143
Notr current
word
×0.001
4144
Phase 1-2 current
word
×0.001
4145
Phase 2-3 current
word
×0.001
4146
Phase 3-1 current
word
×0.001
4147
Voltage unbalance
smallint
4148
Current unbalance
smallint
This is not the complete map: 50 of 812 registers are listed above. Click "Read register values online" to read any register of your device in the browser, or download the program to log the complete map.
Registers in the map: 766 (the first 50 are listed below; the browser reader and the data loggers use the complete map). function 3 (holding registers). byte order big-endian. data types: datetime, double, dword, int64, single, smallint, string, word.
MODBUS offset
Description
Units
Data type
Scale
5
Program version (V2.03)
string
formula
8
File system version (V1.00)
string
formula
0
Country code (869)
word
1
Company code (7436)
word
2
Product code (88503)
dword
4
Barcode check (9)
word
6
User define device number H
word
7
User define device number L
word
4092
RealTime date
datetime
formula
4095
VTRFWM
word
×0.1
4096
CTRF
word
4097
Device working informations
word
4098
Phase1 voltage TRMS value
word
×0.1
4099
Phase2 voltage TRMS value
word
×0.1
4100
Phase3 voltage TRMS value
word
×0.1
4101
Phase1 current TRMS value
word
×0.001
4102
Phase2 current TRMS value
word
×0.001
4103
Phase3 current TRMS value
word
×0.001
4104
Phase1 active power TRMS value
smallint
formula
4105
Phase2 active power TRMS value
smallint
formula
4106
Phase3 active power TRMS value
smallint
formula
4107
Phase1 reactive power TRMS value
smallint
formula
4108
Phase2 reactive power TRMS value
smallint
formula
4109
Phase3 reactive power TRMS value
smallint
formula
4110
Phase1 appeared power TRMS value
word
formula
4111
Phase2 appeared power TRMS value
word
formula
4112
Phase3 appeared power TRMS value
word
formula
4113
Phase1 CosFiValue
smallint
×0.001
4114
Phase2 CosFiValue
smallint
×0.001
4115
Phase3 CosFiValue
smallint
×0.001
4116
Sum CosFiValue
smallint
×0.001
4117
Phase1 PowerFactor
smallint
×0.001
4118
Phase2 PowerFactor
smallint
×0.001
4119
Phase3 PowerFactor
smallint
×0.001
4120
SUM PowerFactor
smallint
×0.001
4121
Total active power
smallint
formula
4122
Total positive ReactivePower (+q) (unsigned)
word
formula
4123
Total negative reactive power (-q) (unsigned)
word
formula
4124
Sum reactive power ((+q)-(-q))
smallint
formula
4125
Sum appeared power
word
formula
4126
Frequency
word
×0.1
4127
Phase order number of frequency supply phase
word
4133
Phase-current connection and error messages
word
4134
Voltage1 ZerocrossOver (Referance)(Everytime 0)
word
4135
Current1 ZeroCrossover (Angle value)(0-359)
word
4136
Voltage2 ZerocrossOver (Angle value)(0-359)
word
4137
Current2 ZeroCrossover (Angle value)(0-359)
word
4138
Voltage3 ZerocrossOver (Angle value)(0-359)
word
4139
Current3 ZeroCrossover (Angle value)(0-359)
word
4140
Phase 1-2 voltage
word
×0.1
This is not the complete map: 50 of 766 registers are listed above. Click "Read register values online" to read any register of your device in the browser, or download the program to log the complete map.
Registers in the map: 1124 (the first 50 are listed below; the browser reader and the data loggers use the complete map). function 3 (holding registers). byte order big-endian. data types: datetime, double, dword, int64, single, smallint, string, word.
MODBUS offset
Description
Units
Data type
Scale
5
Program version (V2.04)
string
formula
8
File system version (V1.00)
string
formula
0
Country code (869)
word
1
Company code (7436)
word
2
Product code (88503)
dword
4
Barcode check (9)
word
6
User define device number H
word
7
User define device number L
word
4092
RealTime date
datetime
formula
4095
VTRFWM
word
×0.1
4096
CTRF
word
4097
Device working informations
word
4098
Phase1 voltage TRMS value
word
×0.1
4099
Phase2 voltage TRMS value
word
×0.1
4100
Phase3 voltage TRMS value
word
×0.1
4101
Phase1 current TRMS value
word
×0.001
4102
Phase2 current TRMS value
word
×0.001
4103
Phase3 current TRMS value
word
×0.001
4104
Phase1 active power TRMS value
smallint
formula
4105
Phase2 active power TRMS value
smallint
formula
4106
Phase3 active power TRMS value
smallint
formula
4107
Phase1 reactive power TRMS value
smallint
formula
4108
Phase2 reactive power TRMS value
smallint
formula
4109
Phase3 reactive power TRMS value
smallint
formula
4110
Phase1 appeared power TRMS value
word
formula
4111
Phase2 appeared power TRMS value
word
formula
4112
Phase3 appeared power TRMS value
word
formula
4113
Phase1 CosFiValue
smallint
×0.001
4114
Phase2 CosFiValue
smallint
×0.001
4115
Phase3 CosFiValue
smallint
×0.001
4116
Sum CosFiValue
smallint
×0.001
4117
Phase1 PowerFactor
smallint
×0.001
4118
Phase2 PowerFactor
smallint
×0.001
4119
Phase3 PowerFactor
smallint
×0.001
4120
SUM PowerFactor
smallint
×0.001
4121
Total active power
smallint
formula
4122
Total positive ReactivePower (+q) (unsigned)
word
formula
4123
Total negative reactive power (-q) (unsigned)
word
formula
4124
Sum reactive power ((+q)-(-q))
smallint
formula
4125
Sum appeared power
word
formula
4126
Frequency
word
×0.1
4127
Phase order number of frequency supply phase
word
4133
Phase-current connection and error messages
word
4134
Voltage1 ZerocrossOver (Referance)(Everytime 0)
word
4135
Current1 ZeroCrossover (Angle value)(0-359)
word
4136
Voltage2 ZerocrossOver (Angle value)(0-359)
word
4137
Current2 ZeroCrossover (Angle value)(0-359)
word
4138
Voltage3 ZerocrossOver (Angle value)(0-359)
word
4139
Current3 ZeroCrossover (Angle value)(0-359)
word
4140
Phase 1-2 voltage
word
×0.1
This is not the complete map: 50 of 1124 registers are listed above. Click "Read register values online" to read any register of your device in the browser, or download the program to log the complete map.
Registers in the map: 446 (the first 50 are listed below; the browser reader and the data loggers use the complete map). function 3 (holding registers). byte order big-endian. data types: double, dword, single, smallint, word.
MODBUS offset
Description
Units
Data type
Scale
5
Program communication version
word
0
Country code
word
1
Company code
word
2
Product code
dword
4
Barcode check
word
6
User define number H
word
7
User define number L
word
4096
Current transformer ratio
word
4097
Device working information bits
word
4098
Input voltage phase1
V
word
×0.1
4099
Input voltage phase2
V
word
×0.1
4100
Input voltage phase3
V
word
×0.1
4101
Input current phase1
A
word
×0.001
4102
Input current phase2
A
word
×0.001
4103
Input current phase3
A
word
×0.001
4104
Input active power phase1
W
word
formula
4105
Input active power phase2
W
word
formula
4106
Input active power phase3
W
word
formula
4107
Input reactive power phase1
var
smallint
formula
4108
Input reactive power phase2
var
smallint
formula
4109
Input reactive power phase3
var
smallint
formula
4110
Input appearent power phase1
VA
word
formula
4111
Input appearent power phase2
VA
word
formula
4112
Input appearent power phase3
VA
word
formula
4113
Cos phase1
smallint
4114
Cos phase2
smallint
4115
Cos phase3
smallint
4116
SUM cos
smallint
4117
Tan 1 phase1
smallint
4118
Tan 2 phase2
smallint
4119
Tan 3 phase3
smallint
4120
SUM tan
smallint
4121
Total active power
W
word
formula
4122
Total inductive power
var
word
formula
4123
Total capacitive power
var
word
formula
4124
SUM reactive power
var
smallint
formula
4125
SUM appearent power
VA
word
formula
4126
Frequency
Hz
word
×0.1
4127
Temperature
CD
smallint
4128
Phase alarms output bits for phase1
word
4129
Phase alarms output bits for phase2
word
4130
Phase alarms output bits for phase3
word
4132
Step protection types
word
4133
Warnings for voltage and no current
word
4134
Voltage1 ZeroCrossOverAngle
deg
word
4135
Current1 ZeroCrossOverAngle
deg
word
4136
Voltage2 ZeroCrossOverAngle
deg
word
4137
Current2 ZeroCrossOverAngle
deg
word
4138
Voltage3 ZeroCrossOverAngle
deg
word
4139
Current3 ZeroCrossOverAngle
deg
word
This is not the complete map: 50 of 446 registers are listed above. Click "Read register values online" to read any register of your device in the browser, or download the program to log the complete map.
Note: Products and companies mentioned here are used only for definition and identification purposes and can be trademarks and/or registered trademarks of the respective companies.