Satec (BFM136,BFM036) - MODBUS Registers Map
MODBUS offset
Description
Units
Data type
13312
V1 voltage
V
dword
13314
V2 voltage
V
dword
13316
V3 voltage
V
dword
13318
I1 current
A
dword
13320
I2 current
A
dword
13322
I3 current
A
dword
13324
kWLI
integer
13326
kW L2
integer
13328
kW L3
integer
13330
Kvar L1
integer
13332
Kvar L2
integer
13334
Kvar L3
integer
13336
kVA L1
dword
13338
kVA L2
dword
13340
kVA L3
dword
13342
Power factor L1
integer
13344
Power factor L2
integer
13346
Power factor L3
integer
13372
V12 voltage
V
dword
13374
V23 voltage
V
dword
13376
V31 voltage
V
dword
13440
1-cycle low phase values. Low L-N voltage
V
dword
13442
1-cycle low phase values. Low current
A
dword
13444
1-cycle low phase values. Low kW
integer
13446
1-cycle low phase values. Low kvar
integer
13448
1-cycle low phase values. Low kVA
dword
13450
1-cycle low phase values. Low PF lag
dword
13568
1-cycle high phase values. High L-N voltage
V
dword
13570
1-cycle high phase values. High current
A
dword
13572
1-cycle high phase values. High kW
integer
13574
1-cycle high phase values. High kvar
integer
13576
1-cycle high phase values. High kVA
dword
13578
1-cycle high phase values. High PF lag
dword
13580
1-cycle high phase values. High PF lead
dword
13696
1-cycle total values. Total kW
integer
13698
1-cycle total values. Total kvar
integer
13700
1-cycle total values. Total kVA
dword
13702
1-cycle total values. Total PF
integer
13704
1-cycle total values. Total PF lag
dword
13706
1-cycle total values. Total PF lead
dword
13708
1-cycle total values. Total kW import
dword
31
1-cycle total values. Total kvar import
dword
33
1-cycle total values. Total kvar export
dword
13826
1-cycle auxiliary values. In (neutral) current
A
dword
13828
1-cycle auxiliary values. Frequency
Hz
dword
13830
1-cycle auxiliary values. Voltage unbalance
V
dword
13832
1-cycle auxiliary values. Current unbalance
A
dword
13888
Phasor. V1 voltage magnitude
V
dword
13890
Phasor. V2 voltage magnitude
V
dword
13892
Phasor. V3 voltage magnitude
V
dword
There are more MODBUS items for this device. Please download the program to discover all registers.
Related MODBUS registers maps
Note: Products and companies mentioned here are used only for definition and identification purposes and can be trademarks and/or registered trademarks of the respective companies.