bg

Satec - MODBUS Registers Map - Data Logging

The data can be automatically logged 24/7 into a database, CSV files, or Excel spreadsheets using the Advanced Serial Data Logger (for MODBUS RTU) or Advanced TCP/IP Data Logger (for MODBUS TCP) software. These data logging tools provide continuous and reliable Satec data logging and log.

Do you not know the meter address? Scan the device address online

Satec (BFM136,BFM036) - MODBUS Registers Map

MODBUS offset
Description
Units
Data type
13312
V1 voltage
V
dword
13314
V2 voltage
V
dword
13316
V3 voltage
V
dword
13318
I1 current
A
dword
13320
I2 current
A
dword
13322
I3 current
A
dword
13324
kWLI
 
integer
13326
kW L2
 
integer
13328
kW L3
 
integer
13330
Kvar L1
 
integer
13332
Kvar L2
 
integer
13334
Kvar L3
 
integer
13336
kVA L1
 
dword
13338
kVA L2
 
dword
13340
kVA L3
 
dword
13342
Power factor L1
 
integer
13344
Power factor L2
 
integer
13346
Power factor L3
 
integer
13372
V12 voltage
V
dword
13374
V23 voltage
V
dword
13376
V31 voltage
V
dword
13440
1-cycle low phase values. Low L-N voltage
V
dword
13442
1-cycle low phase values. Low current
A
dword
13444
1-cycle low phase values. Low kW
 
integer
13446
1-cycle low phase values. Low kvar
 
integer
13448
1-cycle low phase values. Low kVA
 
dword
13450
1-cycle low phase values. Low PF lag
 
dword
13568
1-cycle high phase values. High L-N voltage
V
dword
13570
1-cycle high phase values. High current
A
dword
13572
1-cycle high phase values. High kW
 
integer
13574
1-cycle high phase values. High kvar
 
integer
13576
1-cycle high phase values. High kVA
 
dword
13578
1-cycle high phase values. High PF lag
 
dword
13580
1-cycle high phase values. High PF lead
 
dword
13696
1-cycle total values. Total kW
 
integer
13698
1-cycle total values. Total kvar
 
integer
13700
1-cycle total values. Total kVA
 
dword
13702
1-cycle total values. Total PF
 
integer
13704
1-cycle total values. Total PF lag
 
dword
13706
1-cycle total values. Total PF lead
 
dword
13708
1-cycle total values. Total kW import
 
dword
31
1-cycle total values. Total kvar import
 
dword
33
1-cycle total values. Total kvar export
 
dword
13826
1-cycle auxiliary values. In (neutral) current
A
dword
13828
1-cycle auxiliary values. Frequency
Hz
dword
13830
1-cycle auxiliary values. Voltage unbalance
V
dword
13832
1-cycle auxiliary values. Current unbalance
A
dword
13888
Phasor. V1 voltage magnitude
V
dword
13890
Phasor. V2 voltage magnitude
V
dword
13892
Phasor. V3 voltage magnitude
V
dword
There are more MODBUS items for this device. Please download the program to discover all registers.

Related MODBUS registers maps

Note: Products and companies mentioned here are used only for definition and identification purposes and can be trademarks and/or registered trademarks of the respective companies.

MODBUS COM Port Connection