Socomec - MODBUS Registers Map - Data Logging

The data can be automatically logged 24/7 into a database, CSV files, or Excel spreadsheets using the Advanced Serial Data Logger (for MODBUS RTU) or Advanced TCP/IP Data Logger (for MODBUS TCP) software. These data logging tools provide continuous and reliable Socomec data logging and log.

Do you not know the meter address? Scan the device address online

Socomec (Countis ECI2) - MODBUS Registers Map

MODBUS offset
Description
Units
Data type
37072
Label of custom unit
 
string(4)
45058
Save context count
 
dword
40192
Name
 
string(10)
40197
Mode: 0: disabled 1: logical state 2: analogical value 3: combination
 
word
40198
Operand1
 
word
40199
Operand2
 
word
40200
Severity
 
word
40201
Logical mode
 
word
40202
Combination mode
 
word
40203
Analogical value comparison type
 
word
40204
AnaValHyst
 
word
40205
AnaValLow
 
dword
40207
AnaValHigh
 
dword
40209
Name
 
string(10)
40214
Mode: 0: disabled 1: logical state 2: analogical value 3: combination
 
word
40215
Operand1
 
word
40216
Operand2
 
word
40217
Severity: 0: none 1: information 2: warning 3: default
 
word
40218
Logical mode: 0: low state 1: high state 2: falling edge 3: rising edge 4: both falling and rising edge
 
word
40219
Combination mode: 0: OR 1: AND
 
word
40220
Analogical value comparison type: 0: low and high comparison 1: only high 2: only low 3: match with high level on rising 4: match with low level on falling
 
word
40221
AnaValHyst
 
word
40222
AnaValLow
 
dword
40224
AnaValHigh
 
dword
40226
Name
 
string(10)
40231
Mode: 0: disabled 1: logical state 2: analogical value 3: combination
 
word
40232
Operand1
 
word
40233
Operand2
 
word
40234
Severity: 0: none 1: information 2: warning 3: default
 
word
40235
Logical mode: 0: low state 1: high state 2: falling edge 3: rising edge 4: both falling and rising edge
 
word
40236
Combination mode: 0: OR 1: AND
 
word
40237
Analogical value comparison type: 0: low and high comparison 1: only high 2: only low 3: match with high level on rising 4: match with low level on falling
 
word
40238
AnaValHyst
 
word
40239
AnaValLow
 
dword
40241
AnaValHigh
 
dword
40243
Name
 
string(10)
40248
Mode: 0: disabled 1: logical state 2: analogical value 3: combination
 
word
40249
Operand1
 
word
40250
Operand2
 
word
40251
Severity: 0: none 1: information 2: warning 3: default
 
word
40252
Logical mode: 0: low state 1: high state 2: falling edge 3: rising edge 4: both falling and rising edge
 
word
40253
Combination mode: 0: OR 1: AND
 
word
40254
Analogical value comparison type: 0: low and high comparison 1: only high 2: only low 3: match with high level on rising 4: match with low level on falling
 
word
40255
AnaValHyst
 
word
40256
AnaValLow
 
dword
40258
AnaValHigh
 
dword
40260
Name
 
string(10)
40265
Mode: 0: disabled 1: logical state 2: analogical value 3: combination
 
word
40266
Operand1
 
word
40267
Operand2
 
word
There are more MODBUS items for this device. Please download the program to discover all registers.

Socomec (Countis ECI3) - MODBUS Registers Map

MODBUS offset
Description
Units
Data type
38020
Input 1 absolute value
 
dword
38023
Input 2 absolute value
 
dword
38027
Input 1 value for 0mA
 
dword
38029
Input 1 value for 20mA
 
dword
38033
Input 2 value for 0mA
 
dword
38035
Input 2 value for 20mA
 
dword
39170
Integration period
 
word
39172
Numerator rate
 
word
39173
Denominator rate
 
word
39177
Value without CT*VT rate
 
word
39314
Integration period
 
word
39316
Numerator rate
 
word
39317
Denominator rate
 
word
39321
Value without CT*VT rate
 
word
39936
Name
 
string(10)
39941
Mode: 0: disabled 1: 0-20mA 2: 4-20mA
 
word
39942
Unit: 0: A 1: V 2: W 3: kW 4: VAR 5: kVAR 6: VA 7: kVA 8: C 9: F 10: mbar 11: bar 12: custom unit
 
word
39943
Integration time
 
word
39944
Synchro type: 0: RTC 1: external
 
word
39945
X_Pt1
 
word
39946
Y_Pt1
 
dword
39948
X_Pt2
 
word
39949
Y_Pt2
 
dword
39951
X_Pt3
 
word
39952
Y_Pt3
 
dword
39954
X_Pt4
 
word
39955
Y_Pt4
 
dword
39957
X_Pt5
 
word
39958
Y_Pt5
 
dword
39960
Name
 
string(10)
39965
Mode: 0: disabled 1: 0-20mA 2: 4-20mA
 
word
39966
Unit: 0: A 1: V 2: W 3: kW 4: VAR 5: kVAR 6: VA 7: kVA 8: C 9: F 10: mbar 11: bar 12: custom unit
 
word
39967
Integration time
 
word
39968
Synchro type: 0: RTC 1: external
 
word
39969
X_Pt1
 
word
39970
Y_Pt1
 
dword
39972
X_Pt2
 
word
39973
Y_Pt2
 
dword
39975
X_Pt3
 
word
39976
Y_Pt3
 
dword
39978
X_Pt4
 
word
39979
Y_Pt4
 
dword
39981
X_Pt5
 
word
39982
Y_Pt5
 
dword
39869
Load curves base integration time
 
word
39872
External synchro type: 0: disabled 1: input 7 2: COM
 
word
39873
External synchro period
 
word
39874
Currency unit: 0: euro 1: US dollar 2: GB pound 3: yuan 4: other
 
word
37072
Label of custom unit
 
string(4)
45058
Save context count
 
dword
There are more MODBUS items for this device. Please download the program to discover all registers.