Siemens Hipath-3700 - SMDR/CDR call logging & accounting
This data is being extracted with help of the "Advanced PBX Data Logger" software only. It may not be applicable for other software titles.
General
This information is applicable for Siemens Hipath 3000, Siemens Hipath 3350, Siemens Hipath 3500 and Siemens Hipath 3750.
RS232 (V.24). Connection parameters
Default parameters for serial communication: 9600-8-N-1 with hardware flow control.
Configure your PBX using the programming software, like HiPath 3000 Manager.
Go to: System status – Call charges – Output format
Pinout and wiring
PC (9 pin) | PBX (9 pin) |
---|---|
1 | 1 |
2 | 3 |
3 | 2 |
4 | 6 |
5 | 5 |
6 | 4 |
7 | 8 |
8 | 7 |
9 | 9 |
LAN. Connection parameters
Configure your PBX using the programming software, like HiPath 3000 Manager.
Go to: System status – Call charges – Output format (fig. 2)
Output format: LAN-TCP-Client
MRAT: none
Change LAN settings (fig. 3):
IP address: 192.168.1.1 (IP address of your computer with Advanced PBX Data Logger)
TCP port: 1080 (recommended)
Advanced PBX Data Logger
Configure our software to the TCP server mode (fig. 4). Please, note that you should specify the same IP address and port as in the LAN settings. 0.0.0.0 means that the program will listen on all available network interfaces.
Date format
Verify that the date format in the parser and in your PBX are identical.
Configuring a COM port
The COM port number should match the number in your system. You can check the correct port number in Devices Manager → Ports.
1. Add a new configuration with the RS232 data source (if you didn't it before).
2. Select the COM port and configure the communication settings for your PBX corresponding to your PBX settings.


Selecting the correct parser for Siemens Hipath-3700

Siemens Hipath-3700
Siemens Hipath-3700
Data items
Description | Data type | Column name |
---|---|---|
Call time | datetime | CALL_TIME |
CO | string | TRUNK |
External | string | EXT |
Ring | datetime | RING |
Call duration | datetime | CALL_DURATION |
Call duration (s) | integer | CALL_DURATION_S |
Call type | string | CALL_TYPE |
Direction | string | DIRECTION |
Caller phone | string | CALLER_PHONE |
Phone | string | DIALED_PHONE |
Cost | float | COST |
Account code | string | ACC |
Interested in reports for PBX usage?
We offer the PBX Reports utility, which includes various manual, scheduled, and email reports, a built-in web server, and other features. You can implement your call accounting system for Siemens Hipath-3700. Check our PBX Reports utility.
Want PBX call logs in a database?
This is the standard feature: the logger captures and exports SMDR or CDR data in real-time to your database. Check our article about call logging to a database.
Siemens Hipath-3700 related connection settings
Siemens Hipath-35xx (CSV)Siemens Hipath-3550
Siemens Hipath-37xx (CSV)
Siemens Hipath-37xx (Delimited by Pipe)
Quick jump to the connection settings for other PBXs or connection formats ↴
Note: Products and companies mentioned here are used only for definition and identification purposes and can be trademarks and/or registered trademarks of the respective companies.
Related topics: Advanced PBX Data Logger
hereCall logging Call accounting SMDR to SQL SMDR Listener Cables and signals