Connect Carlo Gavazzi to the computer through a USB-to-serial or RS485 adapter and read its registers in your browser: click "Read register values online" under the model (Chrome or Edge, nothing to install). The tables below list the MODBUS offset, unit, data type and scale of every register shown.
For logging 24/7 into a database, CSV files or Excel, use the Advanced Serial Data Logger (for MODBUS RTU) or Advanced TCP/IP Data Logger (for MODBUS TCP): they poll the complete map of every model on this page and provide continuous Carlo Gavazzi data logger and record.
Do you not know the meter address? Scan the device address online
Carlo Gavazzi (EM100,ET100) - MODBUS Maps
Connection and addressing notes
- Protocol
- Modbus
- Access
- read only
- Function codes
- 03 read, 04 read
- Register addressing
- table lists Modicom address (1-based) and physical address (0-based hex)
Registers in the map: 40. function 4 (input registers). byte order big-endian. data types: integer, smallint.
| MODBUS offset | Description | Units | Data type | Scale |
|---|
| 0 | V L N | V | integer | ×0.1 |
| 2 | A | A | integer | ×0.001 |
| 4 | W | W | integer | |
| 6 | Va | | integer | |
| 8 | Var | var | integer | ×0.1 |
| 10 | Wdmd | W | integer | |
| 12 | Wdmd peak | W | integer | |
| 14 | Pf | | smallint | |
| 15 | Hz | Hz | smallint | |
| 16 | Kwh(+) tot | kWh | integer | |
| 18 | Kvarh(+) tot | kvar | integer | ×0.1 |
| 20 | Kwh(+) partial | kWh | integer | |
| 22 | Kvarh(+) partial | kvar | integer | ×0.1 |
| 24 | Kwh(+) tariff 1 | kWh | integer | |
| 26 | Kwh(+) tariff 2 | kWh | integer | |
| 32 | Kwh( ) tot | kWh | integer | |
| 34 | Kvarh( ) tot | kvar | integer | ×0.1 |
| 44 | Hour counter meter | | integer | ×0.01 |
| 256 | A | A | integer | ×0.001 |
| 258 | V L N | V | integer | ×0.1 |
| 262 | W | W | integer | |
| 264 | Vat | | integer | |
| 266 | Var Z | var | integer | ×0.1 |
| 268 | Pf Z | | integer | ×0.001 |
| 272 | Hz | Hz | integer | |
| 274 | Kwh(+) tot | kWh | integer | |
| 276 | Kvarh(+) tot | kvar | integer | ×0.1 |
| 278 | Kwh( ) tot | kWh | integer | |
| 280 | Kvarh( ) tot | kvar | integer | ×0.1 |
| 282 | Kwdmd | W | integer | |
| 284 | Kwdmd peak | W | integer | |
| 328 | Kwh(+) partial | kWh | integer | |
| 330 | Kvarh(+) partial | kvar | integer | ×0.1 |
| 338 | Kwh(+) tariff 1 | kWh | integer | |
| 340 | Kwh(+) tariff 2 | kWh | integer | |
| 342 | Kwh(+) tariff 3 | | integer | |
| 336 | Kwh(+) tariff 4 | | integer | |
| 346 | Kwh( ) partial | | integer | |
| 384 | Thd( 16h) A | | integer | |
| 386 | Chd( 16h) | V | integer | |
Carlo Gavazzi (EM111,EM112,ET112) - MODBUS Registers
Connection and addressing notes
- Protocol
- Modbus
- Access
- read only
- Function codes
- 03 read, 04 read
- Register addressing
- table lists Modicom address (1-based) and physical address (0-based hex)
Registers in the map: 51 (the first 50 are listed below; the browser reader and the data loggers use the complete map). function 4 (input registers). byte order big-endian. data types: int64, integer, smallint.
| MODBUS offset | Description | Units | Data type | Scale |
|---|
| 0 | V L-N | V | integer | ×0.1 |
| 2 | A | A | integer | ×0.001 |
| 4 | W | W | integer | ×0.1 |
| 6 | VA | VA | integer | ×0.1 |
| 8 | Var | var | integer | ×0.1 |
| 10 | W dmd | W | integer | ×0.1 |
| 12 | W dmd peak | W | integer | ×0.1 |
| 14 | PF | PF | smallint | ×0.001 |
| 15 | Hz | Hz | smallint | ×0.1 |
| 16 | kWh (+) TOT | kWh | integer | ×0.1 |
| 18 | Kvarh (+) TOT | kvarh | integer | ×0.1 |
| 20 | kWh (+) PARTIAL | kWh | integer | ×0.1 |
| 22 | Kvarh (+) PARTIAL | kvarh | integer | ×0.1 |
| 24 | kWh (+) T1 | kWh | integer | ×0.1 |
| 26 | kWh (+) T2 | kWh | integer | ×0.1 |
| 32 | kWh (-) TOT | kWh | integer | ×0.1 |
| 34 | Kvarh (-) TOT | kvarh | integer | ×0.1 |
| 44 | Hour counter | h | integer | ×0.01 |
| 256 | A | A | integer | ×0.001 |
| 258 | V L-N | V | integer | ×0.1 |
| 262 | W | W | integer | ×0.1 |
| 264 | VA | VA | integer | ×0.1 |
| 266 | Var | var | integer | ×0.1 |
| 268 | PF | PF | integer | ×0.001 |
| 272 | Hz | Hz | integer | ×0.1 |
| 274 | kWh (+) TOT | kWh | integer | ×0.1 |
| 276 | Kvarh (+) TOT | kvarh | integer | ×0.1 |
| 278 | kWh (-) TOT | kWh | integer | ×0.1 |
| 280 | Kvarh (-) TOT | kvarh | integer | ×0.1 |
| 282 | kW dmd | W | integer | ×0.1 |
| 284 | kW dmd peak | W | integer | ×0.1 |
| 328 | kWh (+) PARTIAL | kWh | integer | ×0.1 |
| 330 | Kvarh (+) PARTIAL | kvarh | integer | ×0.1 |
| 338 | kWh (+) T1 | kWh | integer | ×0.1 |
| 340 | kWh (+) T2 | kWh | integer | ×0.1 |
| 1024 | kWh (+) TOT INTeger part | kWh | integer | |
| 1026 | kWh (+) TOT DECimal part | kWh | integer | ×0.001 |
| 1028 | Kvarh (+) TOT INTeger part | kvarh | integer | |
| 1030 | Kvarh (+) TOT DECimal part | kvarh | integer | ×0.001 |
| 1032 | kWh (-) TOT INTeger part | | integer | |
| 1034 | kWh (-) TOT DECimal part | kWh | integer | ×0.001 |
| 1036 | Kvarh (-) TOT INTeger part | kvarh | integer | |
| 1038 | Kvarh (-) TOT DECimal part | kvarh | integer | ×0.001 |
| 1280 | kWh (+) TOT | | int64 | |
| 1284 | Kvarh (+) TOT | | int64 | |
| 1288 | kWh (+) partial | | int64 | |
| 1292 | Kvarh (+) partial | | int64 | |
| 1308 | kWh (-) TOT | | int64 | |
| 1312 | kWh (-) partial | | int64 | |
| 1316 | Kvarh (-) TOT | | int64 | |
This is not the complete map: 50 of 51 registers are listed above. Click "Read register values online" to read any register of your device in the browser, or download the program to log the complete map.
Carlo Gavazzi EM21 - MODBUS Values
Connection and addressing notes
- Protocol
- Modbus
- Access
- read only
- Function codes
- 03, 04
- Register addressing
- table lists Modicom address (1-based) and physical address (0-based hex)
Registers in the map: 31. function 4 (holding registers). byte order big-endian. data types: integer, smallint.
| MODBUS offset | Description | Units | Data type | Scale |
|---|
| 0 | V l1-n | V | integer | ×0.1 |
| 2 | V l2-n | V | integer | ×0.1 |
| 4 | V l3-n | V | integer | ×0.1 |
| 6 | V l1-l2 | V | integer | ×0.1 |
| 8 | V l2-l3 | V | integer | ×0.1 |
| 10 | V l3-l1 | V | integer | ×0.1 |
| 12 | A l1 | A | integer | ×0.001 |
| 14 | A l2 | A | integer | ×0.001 |
| 16 | A l3 | A | integer | ×0.001 |
| 18 | W l1 | W | integer | ×0.1 |
| 20 | W l2 | W | integer | ×0.1 |
| 22 | W l3 | W | integer | ×0.1 |
| 24 | Va l1 | VA | integer | ×0.1 |
| 26 | Va l2 | VA | integer | ×0.1 |
| 28 | Va l3 | VA | integer | ×0.1 |
| 30 | Var l1 | var | integer | ×0.1 |
| 32 | Var l2 | var | integer | ×0.1 |
| 34 | Var l3 | var | integer | ×0.1 |
| 36 | V l-n | V | integer | ×0.1 |
| 38 | V l-l | V | integer | ×0.1 |
| 40 | W | W | integer | ×0.1 |
| 42 | Va | VA | integer | ×0.1 |
| 44 | Var | var | integer | ×0.1 |
| 46 | Pf l1 | | smallint | |
| 47 | Pf l2 | | smallint | |
| 48 | Pf l3 | | smallint | |
| 49 | Pf | PF | smallint | ×0.001 |
| 50 | Phase sequence | | smallint | |
| 51 | Hz | | smallint | |
| 52 | Kwh(+) tot | kWh | integer | ×0.1 |
| 54 | Kvarh(+) tot | kvarh | integer | ×0.1 |
Carlo Gavazzi (EM24) - MODBUS Values
Connection and addressing notes
- Protocol
- Modbus
- Access
- read only
- Function codes
- 03, 04
- Register addressing
- table lists Modicom address (1-based) and physical address (0-based hex)
Registers in the map: 55 (the first 50 are listed below; the browser reader and the data loggers use the complete map). function 4 (input registers). byte order big-endian. data types: integer, smallint.
| MODBUS offset | Description | Units | Data type | Scale |
|---|
| 0 | V L1 N | | integer | ×0.1 |
| 2 | V L2 N | | integer | ×0.1 |
| 4 | V L3 N | | integer | ×0.1 |
| 6 | V L1 L2 | | integer | ×0.1 |
| 8 | V L2 L3 | | integer | ×0.1 |
| 10 | V L3 L1 | | integer | ×0.1 |
| 12 | A L1 | | integer | ×0.001 |
| 14 | A L2 | | integer | ×0.001 |
| 16 | A L3 | | integer | ×0.001 |
| 18 | W L1 | | integer | ×0.1 |
| 20 | W L2 | | integer | ×0.1 |
| 22 | W L3 | | integer | ×0.1 |
| 24 | Va L1 | | integer | ×0.1 |
| 26 | Va L2 | | integer | ×0.1 |
| 28 | Va L3 | | integer | ×0.1 |
| 30 | Var L1 | | integer | ×0.1 |
| 32 | Var L2 | | integer | ×0.1 |
| 34 | Var L3 | | integer | ×0.1 |
| 36 | V L N | | integer | ×0.1 |
| 38 | V L L | | integer | ×0.1 |
| 40 | W | | integer | ×0.1 |
| 42 | Va | | integer | ×0.1 |
| 44 | Var | | integer | ×0.1 |
| 46 | Dmd | W | integer | ×0.1 |
| 48 | Dmd | VA | integer | ×0.1 |
| 50 | Pf L1 | | smallint | ×0.001 |
| 51 | Pf L2 | | smallint | ×0.001 |
| 52 | Pf L3 | | smallint | ×0.001 |
| 53 | Pf | | smallint | ×0.001 |
| 54 | Phase sequence | | smallint | |
| 55 | Hz | Hz | smallint | ×0.1 |
| 56 | Dmd W max | | integer | ×0.1 |
| 58 | Dmd va max | | integer | ×0.1 |
| 60 | Dmd A max | | integer | ×0.001 |
| 62 | Kwh(+) tot | kW | integer | ×0.1 |
| 64 | Kvarh(+) tot | kvar | integer | ×0.1 |
| 66 | Kwh(+) par | kW | integer | ×0.1 |
| 68 | Kvarh(+) par | kvar | integer | ×0.1 |
| 70 | Kwh(+) L1 | kW | integer | ×0.1 |
| 72 | Kwh(+) L2 | kW | integer | ×0.1 |
| 74 | Kwh(+) L3 | kW | integer | ×0.1 |
| 76 | Kwh(+) T1 | kW | integer | ×0.1 |
| 78 | Kwh(+) T2 | kW | integer | ×0.1 |
| 80 | Kwh(+) T3 | kW | integer | ×0.1 |
| 82 | Kwh(+) T4 | kW | integer | ×0.1 |
| 84 | Kvarh(+) T1 | kvar | integer | ×0.1 |
| 86 | Kvarh(+) T2 | kvar | integer | ×0.1 |
| 88 | Kvarh(+) T3 | kvar | integer | ×0.1 |
| 90 | Kvarh(+) T4 | kvar | integer | ×0.1 |
| 92 | Kwh( ) tot | kW | integer | ×0.1 |
This is not the complete map: 50 of 55 registers are listed above. Click "Read register values online" to read any register of your device in the browser, or download the program to log the complete map.
Carlo Gavazzi (EM26) - Measurement Data
Connection and addressing notes
- Protocol
- Modbus
- Access
- read only
- Function codes
- 03, 04
- Register addressing
- table lists Modicom address (1-based) and physical address (0-based hex)
Registers in the map: 67 (the first 50 are listed below; the browser reader and the data loggers use the complete map). function 4 (input registers). byte order big-endian. data types: integer, smallint.
| MODBUS offset | Description | Units | Data type | Scale |
|---|
| 0 | V L1 N | | integer | ×0.1 |
| 2 | V L2 N | | integer | ×0.1 |
| 4 | V L3 N | | integer | ×0.1 |
| 6 | V L1 L2 | | integer | ×0.1 |
| 8 | V L2 L3 | | integer | ×0.1 |
| 10 | V L3 L1 | | integer | ×0.1 |
| 12 | A L1 | | integer | ×0.001 |
| 14 | A L2 | | integer | ×0.001 |
| 16 | A L3 | | integer | ×0.001 |
| 18 | W L1 | | integer | ×0.1 |
| 20 | W L2 | | integer | ×0.1 |
| 22 | W L3 | | integer | ×0.1 |
| 24 | Va L1 | | integer | ×0.1 |
| 26 | Va L2 | | integer | ×0.1 |
| 28 | Va L3 | | integer | ×0.1 |
| 30 | Var L1 | | integer | ×0.1 |
| 32 | Var L2 | | integer | ×0.1 |
| 34 | Var L3 | | integer | ×0.1 |
| 36 | V L N | | integer | ×0.1 |
| 38 | V L L | | integer | ×0.1 |
| 40 | W | | integer | ×0.1 |
| 42 | Va | | integer | ×0.1 |
| 44 | Var | | integer | ×0.1 |
| 46 | Dmd | W | integer | ×0.1 |
| 48 | Dmd | VA | integer | ×0.1 |
| 50 | Pf L1 | | smallint | ×0.001 |
| 51 | Pf L2 | | smallint | ×0.001 |
| 52 | Pf L3 | | smallint | ×0.001 |
| 53 | Pf | | smallint | ×0.001 |
| 54 | Phase sequence | | smallint | |
| 55 | Hz | Hz | smallint | ×0.1 |
| 56 | Dmd W max | | integer | ×0.1 |
| 58 | Dmd va max | | integer | ×0.1 |
| 60 | Dmd A max | | integer | ×0.001 |
| 62 | Kwh(+) tot | kW | integer | ×0.1 |
| 64 | Kvarh(+) tot | kvar | integer | ×0.1 |
| 66 | Kwh(+) par | kW | integer | ×0.1 |
| 68 | Kvarh(+) par | kvar | integer | ×0.1 |
| 70 | Kwh(+) L1 | kW | integer | ×0.1 |
| 72 | Kwh(+) L2 | kW | integer | ×0.1 |
| 74 | Kwh(+) L3 | kW | integer | ×0.1 |
| 76 | Kwh(+) T1 | kW | integer | ×0.1 |
| 78 | Kwh(+) T2 | kW | integer | ×0.1 |
| 80 | Kwh(+) T3 | kW | integer | ×0.1 |
| 82 | Kwh(+) T4 | kW | integer | ×0.1 |
| 84 | Kvarh(+) T1 | kvar | integer | ×0.1 |
| 86 | Kvarh(+) T2 | kvar | integer | ×0.1 |
| 88 | Kvarh(+) T3 | kvar | integer | ×0.1 |
| 90 | Kvarh(+) T4 | kvar | integer | ×0.1 |
| 92 | Kwh( ) tot | kW | integer | ×0.1 |
This is not the complete map: 50 of 67 registers are listed above. Click "Read register values online" to read any register of your device in the browser, or download the program to log the complete map.
Carlo Gavazzi (EM270) - MODBUS Values
Connection and addressing notes
- Protocol
- Modbus
- Access
- read only
- Function codes
- 03, 04
- Register addressing
- table lists Modicom address (1-based) and physical address (0-based hex)
Registers in the map: 66 (the first 50 are listed below; the browser reader and the data loggers use the complete map). function 4 (input registers). byte order big-endian. data types: integer.
| MODBUS offset | Description | Units | Data type | Scale |
|---|
| 0 | V L1 N | | integer | ×0.1 |
| 2 | V L2 N | | integer | ×0.1 |
| 4 | V L3 N | | integer | ×0.1 |
| 6 | V L1 L2 | | integer | ×0.1 |
| 8 | V L2 L3 | | integer | ×0.1 |
| 10 | V L3 L1 | | integer | ×0.1 |
| 12 | A L1 | | integer | ×0.001 |
| 14 | A L2 | | integer | ×0.001 |
| 16 | A L3 | | integer | ×0.001 |
| 18 | W | | integer | ×0.1 |
| 20 | Va | | integer | ×0.1 |
| 22 | Var | | integer | ×0.1 |
| 24 | Kwh(+)tot | kW | integer | ×0.1 |
| 26 | Kvarh(+)tot | kvar | integer | ×0.1 |
| 28 | W dmd | | integer | ×0.1 |
| 30 | Va dmd | | integer | ×0.1 |
| 32 | W maxdmd | | integer | ×0.1 |
| 34 | Va maxdmd | | integer | ×0.1 |
| 268 | A L1 tcda | | integer | ×0.001 |
| 270 | A L2 tcda | | integer | ×0.001 |
| 272 | A L3 tcda | | integer | ×0.001 |
| 274 | W L1 tcda | | integer | ×0.1 |
| 276 | W L2 tcda | | integer | ×0.1 |
| 278 | W L3 tcda | | integer | ×0.1 |
| 280 | W tot tcda | | integer | ×0.1 |
| 282 | Va tot tcda | | integer | ×0.1 |
| 284 | Var tot tcda | | integer | ×0.1 |
| 286 | Kwh(+)tcda tot | kW | integer | ×0.1 |
| 288 | Kvarh (+)tcda tot | kvar | integer | ×0.1 |
| 290 | W tot tcda dmd | | integer | ×0.1 |
| 292 | Va tot tcda dmd | | integer | ×0.1 |
| 294 | W tot tcda maxdmd | | integer | ×0.1 |
| 296 | Va tot tcda maxdmd | | integer | ×0.1 |
| 298 | Kwh(+) L1 tcda | kW | integer | ×0.1 |
| 300 | Kwh(+) L2 tcda | | integer | ×0.1 |
| 302 | Kwh(+) L3 tcda | | integer | ×0.1 |
| 304 | W L1 tcda dmd | | integer | ×0.1 |
| 306 | W L2 tcda dmd | | integer | ×0.1 |
| 308 | W L3 tcda dmd | | integer | ×0.1 |
| 310 | W L1 tcda maxdmd | | integer | ×0.1 |
| 312 | W L2 tcda maxdmd | | integer | ×0.1 |
| 314 | W L3 tcda maxdmd | | integer | ×0.1 |
| 524 | A L1 tcdb | | integer | ×0.001 |
| 526 | A L2 tcdb | | integer | ×0.001 |
| 528 | A L3 tcdb | | integer | ×0.001 |
| 530 | W L1 tcdb | | integer | ×0.1 |
| 532 | W L2 tcdb | | integer | ×0.1 |
| 534 | W L3 tcdb | | integer | ×0.1 |
| 536 | W tot tcdb | | integer | ×0.1 |
| 538 | Va tot tcdb | | integer | ×0.1 |
This is not the complete map: 50 of 66 registers are listed above. Click "Read register values online" to read any register of your device in the browser, or download the program to log the complete map.
Carlo Gavazzi (EM271) - MODBUS Values
Connection and addressing notes
- Protocol
- Modbus
- Access
- read only
- Function codes
- 03, 04
- Register addressing
- table lists Modicom address (1-based) and physical address (0-based hex)
Registers in the map: 66 (the first 50 are listed below; the browser reader and the data loggers use the complete map). function 4 (input registers). byte order big-endian. data types: integer.
| MODBUS offset | Description | Units | Data type | Scale |
|---|
| 0 | V L1 N | | integer | ×0.1 |
| 2 | V L2 N | | integer | ×0.1 |
| 4 | V L3 N | | integer | ×0.1 |
| 6 | V L1 L2 | | integer | ×0.1 |
| 8 | V L2 L3 | | integer | ×0.1 |
| 10 | V L3 L1 | | integer | ×0.1 |
| 12 | A L1 | | integer | ×0.001 |
| 14 | A L2 | | integer | ×0.001 |
| 16 | A L3 | | integer | ×0.001 |
| 18 | W | | integer | ×0.1 |
| 20 | Va | | integer | ×0.1 |
| 22 | Var | | integer | ×0.1 |
| 24 | Kwh(+)tot | kW | integer | ×0.1 |
| 26 | Kvarh(+)tot | kvar | integer | ×0.1 |
| 28 | W dmd | | integer | ×0.1 |
| 30 | Va dmd | | integer | ×0.1 |
| 32 | W maxdmd | | integer | ×0.1 |
| 34 | Va maxdmd | | integer | ×0.1 |
| 268 | A L1 tcda1 | | integer | ×0.001 |
| 270 | A L2 tcda1 | | integer | ×0.001 |
| 272 | A L3 tcda1 | | integer | ×0.001 |
| 274 | W L1 tcda1 | | integer | ×0.1 |
| 276 | W L2 tcda1 | | integer | ×0.1 |
| 278 | W L3 tcda1 | | integer | ×0.1 |
| 280 | W tot tcda1 | | integer | ×0.1 |
| 282 | Va tot tcda1 | | integer | ×0.1 |
| 284 | Var tot tcda1 | | integer | ×0.1 |
| 286 | Kwh(+)tcda1 tot | kW | integer | ×0.1 |
| 288 | Kvarh (+)tcda1 tot | kvar | integer | ×0.1 |
| 290 | W tot tcda1 dmd | | integer | ×0.1 |
| 292 | Va tot tcda1 dmd | | integer | ×0.1 |
| 294 | W tot tcda1 maxdmd | | integer | ×0.1 |
| 296 | Va tot tcda1 maxdmd | | integer | ×0.1 |
| 298 | Kwh(+) L1 tcda1 | kW | integer | ×0.1 |
| 300 | Kwh(+) L2 tcda1 | kW | integer | ×0.1 |
| 302 | Kwh(+) L3 tcda1 | kW | integer | ×0.1 |
| 304 | W L1 tcda1 dmd | | integer | ×0.1 |
| 306 | W L2 tcda1 dmd | | integer | ×0.1 |
| 308 | W L3 tcda1 dmd | | integer | ×0.1 |
| 310 | W L1 tcda1 maxdmd | | integer | ×0.1 |
| 312 | W L2 tcda1 maxdmd | | integer | ×0.1 |
| 314 | W L3 tcda1 maxdmd | | integer | ×0.1 |
| 524 | A L1 tcda2 | | integer | ×0.001 |
| 526 | A L2 tcda2 | | integer | ×0.001 |
| 528 | A L3 tcda2 | | integer | ×0.001 |
| 530 | W L1 tcda2 | | integer | ×0.1 |
| 532 | W L2 tcda2 | | integer | ×0.1 |
| 534 | W L3 tcda2 | | integer | ×0.1 |
| 536 | W tot tcda2 | | integer | ×0.1 |
| 538 | Va tot tcda2 | | integer | ×0.1 |
This is not the complete map: 50 of 66 registers are listed above. Click "Read register values online" to read any register of your device in the browser, or download the program to log the complete map.
Carlo Gavazzi (EM300,ET300) - MODBUS Maps
Connection and addressing notes
- Protocol
- Modbus
- Access
- read only
- Function codes
- 03, 04
- Register addressing
- table lists Modicom address (1-based) and physical address (0-based hex)
Registers in the map: 122 (the first 50 are listed below; the browser reader and the data loggers use the complete map). function 4 (input registers). byte order big-endian. data types: integer, smallint, word.
| MODBUS offset | Description | Units | Data type | Scale |
|---|
| 770 | Version code | | word | |
| 771 | Revision code | Revision | word | |
| 11 | Carlo Gavazzi Controls identification code | | word | |
| 0 | V L1 N | V | integer | ×0.1 |
| 2 | V L2 N | V | integer | ×0.1 |
| 4 | V L3 N | V | integer | ×0.1 |
| 6 | V L1 L2 | V | integer | ×0.1 |
| 8 | V L2 L3 | V | integer | ×0.1 |
| 10 | V L3 L1 | V | integer | ×0.1 |
| 12 | A L1 | A | integer | ×0.001 |
| 14 | A L2 | A | integer | ×0.001 |
| 16 | A L3 | A | integer | ×0.001 |
| 18 | Kw L1 | W | integer | ×0.1 |
| 20 | Kw L2 | W | integer | ×0.1 |
| 22 | Kw L3 | W | integer | ×0.1 |
| 24 | Kva L1 | | integer | ×0.1 |
| 26 | Kva L2 | | integer | ×0.1 |
| 28 | Kva L3 | | integer | ×0.1 |
| 30 | Kvar L1 | var | integer | ×0.1 |
| 32 | Kvar L2 | var | integer | ×0.1 |
| 34 | Kvar L3 | var | integer | ×0.1 |
| 36 | V L N sys | V | integer | ×0.1 |
| 38 | V L L sys | V | integer | ×0.1 |
| 40 | Kw sys | W | integer | ×0.1 |
| 42 | Kva sys | | integer | |
| 44 | Kvar sys | var | integer | ×0.1 |
| 46 | Pf L1 | | smallint | ×0.001 |
| 47 | Pf L2 | | smallint | ×0.001 |
| 48 | Pf L3 | | smallint | ×0.001 |
| 49 | Pf sys | | smallint | ×0.001 |
| 50 | Phase sequence | | smallint | |
| 51 | Hz | Hz | smallint | ×0.1 |
| 52 | Kwh (+) tot | kWh | integer | ×0.1 |
| 54 | Kvarh (+) tot | kvar | integer | |
| 56 | Kw dmd | W | integer | ×0.1 |
| 58 | Kw dmd peak | W | integer | ×0.1 |
| 60 | Kwh (+) partial | kWh | integer | ×0.1 |
| 62 | Kvarh (+) partial | kvar | integer | ×0.1 |
| 64 | Kwh (+) L1 | kWh | integer | ×0.1 |
| 66 | Kwh (+) L2 | kWh | integer | ×0.1 |
| 68 | Kwh (+) L3 | kWh | integer | ×0.1 |
| 70 | Kwh (+) t1 | kWh | integer | ×0.1 |
| 72 | Kwh (+) t2 | kWh | integer | ×0.1 |
| 74 | Kwh (+) t3 | kWh | integer | |
| 76 | Kwh (+) t4 | kWh | integer | ×0.1 |
| 78 | Kwh ( ) tot | kWh | integer | ×0.1 |
| 80 | Kvarh ( ) tot | kvar | integer | |
| 90 | Hour meter | | integer | ×0.01 |
| 96 | Kwh ( ) L1 | kWh | integer | ×0.1 |
| 98 | Kwh ( ) L2 | kWh | integer | ×0.1 |
This is not the complete map: 50 of 122 registers are listed above. Click "Read register values online" to read any register of your device in the browser, or download the program to log the complete map.
Related MODBUS registers maps
MODBUS Maps Index
CET (PMC-D726M)
CET (PMC-53A)
Carlo Gavazzi (EM33)
Celsa (TNM 35,TNM 96,TNM 144,TNM 300)
Note: Products and companies mentioned here are used only for definition and identification purposes and can be trademarks and/or registered trademarks of the respective companies.