Connect Kael to the computer through a USB-to-serial or RS485 adapter and read its registers in your browser: click "Read register values online" under the model (Chrome or Edge, nothing to install). The tables below list the MODBUS offset, unit, data type and scale of every register shown. For logging 24/7 into a database, CSV files or Excel, use the Advanced Serial Data Logger (for MODBUS RTU) or Advanced TCP/IP Data Logger (for MODBUS TCP): they poll the complete map of every model on this page and provide continuous Kael logger and poll.

Do you not know the meter address? Scan the device address online

Kael (Energy 01) - MODBUS Registers

Connection and addressing notes

Protocol
Modbus
Address register
4002, range 1-255
Baud rate register
4003, 0 = 2400, 1 = 4800, 2 = 9600, 3 = 19200, 4 = 28800, 5 = 38400, 6 = 57600, 7 = 115200 bps
Parity register
4004, 0 = none, 1 = odd, 2 = even
Stop bits register
4005, 0 = 1, 1 = 0.5, 2 = 2, 3 = 1.5
Register addressing
hexadecimal addresses converted to decimal offsets in this map

Registers in the map: 349 (the first 50 are listed below; the browser reader and the data loggers use the complete map). function 3 (holding registers). byte order big-endian. data types: datetime, double, dword, int64, single, smallint, word.

MODBUS offsetDescriptionUnitsData typeScale
5Program communication version word 
0Country code word 
1Company code word 
2Product code dword 
4Barcode check word 
6User define number H word 
7User define number L word 
4092RealTime date datetimeformula
4095Voltage transformer ratio word×0.1
4096Current transformer ratio word 
4097Device working information bits word 
4098Input voltage phase1Vword×0.1
4099Input voltage phase2Vword×0.1
4100Input voltage phase3Vword×0.1
4101Input current phase1Aword×0.001
4102Input current phase2Aword×0.001
4103Input current phase3Aword×0.001
4104Input active power phase1Wsmallintformula
4105Input active power phase2Wsmallintformula
4106Input active power phase3Wsmallintformula
4107Input reactive power phase1varsmallintformula
4108Input reactive power phase2varsmallintformula
4109Input reactive power phase3varsmallintformula
4110Input appearent power phase1VAwordformula
4111Input appearent power phase2VAwordformula
4112Input appearent power phase3VAwordformula
4113Cos phase1 smallint 
4114Cos phase2 smallint 
4115Cos phase3 smallint 
4116SUM cos smallint 
4117PF phase1 smallint 
4118PF phase2 smallint 
4119PF phase3 smallint 
4120SUMPFsmallint 
4121Total active powerWwordformula
4122Total inductive powervarwordformula
4123Total capacitive powervarwordformula
4124SUM reactive powervarsmallintformula
4125SUM appearent powerVAwordformula
4126FrequencyHzword×0.1
4127Frequency measure order smallint 
4133Phase connection and no current alerts word 
4134Voltage1 ZeroCrossOverAngledegword 
4135Current1 ZeroCrossOverAngledegword 
4136Voltage2 ZeroCrossOverAngledegword 
4137Current2 ZeroCrossOverAngledegword 
4138Voltage3 ZeroCrossOverAngledegword 
4139Current3 ZeroCrossOverAngledegword 
4140Input voltage phase1-2Vword×0.1
4141Input voltage phase2-3Vword×0.1

This is not the complete map: 50 of 349 registers are listed above. Click "Read register values online" to read any register of your device in the browser, or download the program to log the complete map.

Kael (Energy-02-PC-96) - Measurement Data

Connection and addressing notes

Protocol
Modbus
Register addressing
hexadecimal addresses
Map offsets
decimal equivalents of the hexadecimal addresses
Register example
0x0FFF = 4095
User device number registers
0x0006 high, 0x0007 low

Registers in the map: 638 (the first 50 are listed below; the browser reader and the data loggers use the complete map). function 3 (holding registers). byte order big-endian. data types: datetime, double, dword, int64, single, smallint, string, word.

MODBUS offsetDescriptionUnitsData typeScale
5Program version stringformula
8File system version (V1.00) stringformula
0Country code (869) word 
1Company code (7436) word 
2Product code (88503) dword 
4Barcode check (9) word 
6User define device number H word 
7User define device number L word 
4092RealTime date datetimeformula
4095VTRFWM word×0.1
4096CTRF word 
4097Device working informations word 
4098Phase1 voltage TRMS value word×0.1
4099Phase2 voltage TRMS value word×0.1
4100Phase3 voltage TRMS value word×0.1
4101Phase1 current TRMS value word×0.001
4102Phase2 current TRMS value word×0.001
4103Phase3 current TRMS value word×0.001
4104Phase1 active power TRMS value smallintformula
4105Phase2 active power TRMS value smallintformula
4106Phase3 active power TRMS value smallintformula
4107Phase1 reactive power TRMS value smallintformula
4108Phase2 reactive power TRMS value smallintformula
4109Phase3 reactive power TRMS value smallintformula
4110Phase1 appeared power TRMS value wordformula
4111Phase2 appeared power TRMS value wordformula
4112Phase3 appeared power TRMS value wordformula
4113Phase1 CosFiValue smallint×0.001
4114Phase2 CosFiValue smallint×0.001
4115Phase3 CosFiValue smallint×0.001
4116Sum CosFiValue smallint×0.001
4117Phase1 PowerFactor smallint×0.001
4118Phase2 PowerFactor smallint×0.001
4119Phase3 PowerFactor smallint×0.001
4120SUM PowerFactor smallint×0.001
4121Total active power smallintformula
4122Total positive ReactivePower (+q) (unsigned) wordformula
4123Total negative reactive power (-q) (unsigned) wordformula
4124Sum reactive power ((+q)-(-q)) smallintformula
4125Sum appeared power wordformula
4126Frequency word×0.1
4127Phase order number of frequency supply phase word 
4133Phase-current connection and error messages word 
4134Voltage1 ZerocrossOver (Referance)(Everytime 0) word 
4135Current1 ZeroCrossover (Angle value)(0-359) word 
4136Voltage2 ZerocrossOver (Angle value)(0-359) word 
4137Current2 ZeroCrossover (Angle value)(0-359) word 
4138Voltage3 ZerocrossOver (Angle value)(0-359) word 
4139Current3 ZeroCrossover (Angle value)(0-359) word 
4140Phase 1-2 voltage word×0.1

This is not the complete map: 50 of 638 registers are listed above. Click "Read register values online" to read any register of your device in the browser, or download the program to log the complete map.

Kael (Multimet-01-PC-96) - MODBUS Measurements

Connection and addressing notes

Protocol
Modbus
Register addressing
hexadecimal addresses
Map offsets
decimal equivalents of the hexadecimal addresses
Register example
0x0FFF = 4095
User device number registers
0x0006 high, 0x0007 low
Write code register
0x4020
Read code register
0x4021

Registers in the map: 108 (the first 50 are listed below; the browser reader and the data loggers use the complete map). function 3 (holding registers). byte order big-endian. data types: datetime, dword, single, smallint, string, word.

MODBUS offsetDescriptionUnitsData typeScale
5Program version (V2.22) stringformula
8File system version (V1.00) stringformula
0Country code (869) word 
1Company code (7436) word 
2Product code (88503) dword 
4Barcode check (9) word 
6User define device number H word 
7User define device number L word 
4092RealTime date datetimeformula
4095VTRFWM word×0.1
4096CTRF word 
4097Device working informations word 
4098Phase1 voltage TRMS value word×0.1
4099Phase2 voltage TRMS value word×0.1
4100Phase3 voltage TRMS value word×0.1
4101Phase1 current TRMS value word×0.001
4102Phase2 current TRMS value word×0.001
4103Phase3 current TRMS value word×0.001
4104Phase1 active power TRMS value smallintformula
4105Phase2 active power TRMS value smallintformula
4106Phase3 active power TRMS value smallintformula
4107Phase1 reactive power TRMS value smallintformula
4108Phase2 reactive power TRMS value smallintformula
4109Phase3 reactive power TRMS value smallintformula
4110Phase1 appeared power TRMS value wordformula
4111Phase2 appeared power TRMS value wordformula
4112Phase3 appeared power TRMS value wordformula
4113Phase1 CosFiValue smallint×0.001
4114Phase2 CosFiValue smallint×0.001
4115Phase3 CosFiValue smallint×0.001
4116Sum CosFiValue smallint×0.001
4117Phase1 PowerFactor smallint×0.001
4118Phase2 PowerFactor smallint×0.001
4119Phase3 PowerFactor smallint×0.001
4120SUM PowerFactor smallint×0.001
4121Total active power smallintformula
4122Total positive ReactivePower (+q) (unsigned) wordformula
4123Total negative reactive power (-q) (unsigned) wordformula
4124Sum reactive power ((+q)-(-q)) smallintformula
4125Sum appeared power wordformula
4126Frequency word×0.1
4127Phase order number of frequency supply phase word 
4133Phase-current connection and error messages word 
4134Voltage1 ZerocrossOver (Referance)(Everytime 0) word 
4135Current1 ZeroCrossover (Angle value)(0-359) word 
4136Voltage2 ZerocrossOver (Angle value)(0-359) word 
4137Current2 ZeroCrossover (Angle value)(0-359) word 
4138Voltage3 ZerocrossOver (Angle value)(0-359) word 
4139Current3 ZeroCrossover (Angle value)(0-359) word 
4140Phase 1-2 voltage word×0.1

This is not the complete map: 50 of 108 registers are listed above. Click "Read register values online" to read any register of your device in the browser, or download the program to log the complete map.

Kael (Multiser 01,Multiser 11,Multiser 13) - Measurement Data

Connection and addressing notes

Protocol
Modbus
Register addressing
hexadecimal addresses
Map offsets
decimal equivalents of the hexadecimal addresses
Register example
0x0FFF = 4095
User device number registers
0x0006 high, 0x0007 low

Registers in the map: 638 (the first 50 are listed below; the browser reader and the data loggers use the complete map). function 3 (holding registers). byte order big-endian. data types: datetime, double, dword, int64, single, smallint, string, word.

MODBUS offsetDescriptionUnitsData typeScale
5Program version (V2.01) stringformula
8File system version (V1.00) stringformula
0Country code (869) word 
1Company code (7436) word 
2Product code (88503) dword 
4Barcode check (9) word 
6User define device number H word 
7User define device number L word 
4092RealTime date datetimeformula
4095VTRFWM word×0.1
4096CTRF word 
4097Device working informations word 
4098Phase1 voltage TRMS value word×0.1
4099Phase2 voltage TRMS value word×0.1
4100Phase3 voltage TRMS value word×0.1
4101Phase1 current TRMS value word×0.001
4102Phase2 current TRMS value word×0.001
4103Phase3 current TRMS value word×0.001
4104Phase1 active power TRMS value smallintformula
4105Phase2 active power TRMS value smallintformula
4106Phase3 active power TRMS value smallintformula
4107Phase1 reactive power TRMS value smallintformula
4108Phase2 reactive power TRMS value smallintformula
4109Phase3 reactive power TRMS value smallintformula
4110Phase1 appeared power TRMS value wordformula
4111Phase2 appeared power TRMS value wordformula
4112Phase3 appeared power TRMS value wordformula
4113Phase1 CosFiValue smallint×0.001
4114Phase2 CosFiValue smallint×0.001
4115Phase3 CosFiValue smallint×0.001
4116Sum CosFiValue smallint×0.001
4117Phase1 PowerFactor smallint×0.001
4118Phase2 PowerFactor smallint×0.001
4119Phase3 PowerFactor smallint×0.001
4120SUM PowerFactor smallint×0.001
4121Total active power smallintformula
4122Total positive ReactivePower (+q) (unsigned) wordformula
4123Total negative reactive power (-q) (unsigned) wordformula
4124Sum reactive power ((+q)-(-q)) smallintformula
4125Sum appeared power wordformula
4126Frequency word×0.1
4127Phase order number of frequency supply phase word 
4133Phase-current connection and error messages word 
4134Voltage1 ZerocrossOver (Referance)(Everytime 0) word 
4135Current1 ZeroCrossover (Angle value)(0-359) word 
4136Voltage2 ZerocrossOver (Angle value)(0-359) word 
4137Current2 ZeroCrossover (Angle value)(0-359) word 
4138Voltage3 ZerocrossOver (Angle value)(0-359) word 
4139Current3 ZeroCrossover (Angle value)(0-359) word 
4140Phase 1-2 voltage word×0.1

This is not the complete map: 50 of 638 registers are listed above. Click "Read register values online" to read any register of your device in the browser, or download the program to log the complete map.

Kael (Multiser 01-96,Multiser 11-96) - MODBUS Registers

Connection and addressing notes

Protocol
Modbus
Register addressing
hexadecimal addresses
Map offsets
decimal equivalents of the hexadecimal addresses
Register example
0x0FFF = 4095
User device number registers
0x0006 high, 0x0007 low

Registers in the map: 638 (the first 50 are listed below; the browser reader and the data loggers use the complete map). function 3 (holding registers). byte order big-endian. data types: datetime, double, dword, int64, single, smallint, string, word.

MODBUS offsetDescriptionUnitsData typeScale
5Program version (V2.12) stringformula
8File system version (V1.00) stringformula
0Country code (869) word 
1Company code (7436) word 
2Product code (88503) dword 
4Barcode check (9) word 
6User define device number H word 
7User define device number L word 
4092RealTime date datetimeformula
4095VTRFWM word×0.1
4096CTRF word 
4097Device working informations word 
4098Phase1 voltage TRMS value word×0.1
4099Phase2 voltage TRMS value word×0.1
4100Phase3 voltage TRMS value word×0.1
4101Phase1 current TRMS value word×0.001
4102Phase2 current TRMS value word×0.001
4103Phase3 current TRMS value word×0.001
4104Phase1 active power TRMS value smallintformula
4105Phase2 active power TRMS value smallintformula
4106Phase3 active power TRMS value smallintformula
4107Phase1 reactive power TRMS value smallintformula
4108Phase2 reactive power TRMS value smallintformula
4109Phase3 reactive power TRMS value smallintformula
4110Phase1 appeared power TRMS value wordformula
4111Phase2 appeared power TRMS value wordformula
4112Phase3 appeared power TRMS value wordformula
4113Phase1 CosFiValue smallint×0.001
4114Phase2 CosFiValue smallint×0.001
4115Phase3 CosFiValue smallint×0.001
4116Sum CosFiValue smallint×0.001
4117Phase1 PowerFactor smallint×0.001
4118Phase2 PowerFactor smallint×0.001
4119Phase3 PowerFactor smallint×0.001
4120SUM PowerFactor smallint×0.001
4121Total active power smallintformula
4122Total positive ReactivePower (+q) (unsigned) wordformula
4123Total negative reactive power (-q) (unsigned) wordformula
4124Sum reactive power ((+q)-(-q)) smallintformula
4125Sum appeared power wordformula
4126Frequency word×0.1
4127Phase order number of frequency supply phase word 
4133Phase-current connection and error messages word 
4134Voltage1 ZerocrossOver (Referance)(Everytime 0) word 
4135Current1 ZeroCrossover (Angle value)(0-359) word 
4136Voltage2 ZerocrossOver (Angle value)(0-359) word 
4137Current2 ZeroCrossover (Angle value)(0-359) word 
4138Voltage3 ZerocrossOver (Angle value)(0-359) word 
4139Current3 ZeroCrossover (Angle value)(0-359) word 
4140Phase 1-2 voltage word×0.1

This is not the complete map: 50 of 638 registers are listed above. Click "Read register values online" to read any register of your device in the browser, or download the program to log the complete map.