Odenberg HALO Sorter data logging - MODBUS registers map


This data is being extracted with the help of the Advanced Serial Data Logger (MODBUS RTU,ASCII) or Advanced TCP/IP Data Logger (MODBUS TCP) software only. It may not applicable for other software titles.

MODBUS offset
Description
Units
Data type
1
System Alarms Flags
 
word
2
Current Program ID
 
word
3
Selected Program ID
 
word
4
Accept Count
 
dword
6
Reject A Count
 
dword
8
Reject B Count
 
dword
10
FM Count
 
dword
14
Undersized Count
 
dword
18
Oversized Count
 
dword
20
Current Application Number
 
word
21
Selected Application Number
 
word
22
Program Files Count
 
word
23
Applications Count
 
word
25
Current User ID
 
word
26
Last User ID
 
word
27
Selected User ID
 
word
28
Selected User Level
 
word
29
Day
 
word
30
Month
 
word
31
Year
 
word
32
Hour
 
word
33
Minute
 
word
34
Second
 
word
290
System Defect Rejector
 
word
355
System Defect Units
 
word
6999
System Sorting Setpoint
 
dword
7255
System Mechanical Value
 
dword
8485
Selected Defect Rejector
 
word
8550
Selected Defect Units
 
word
7383
Selected Sorting Setpoint
 
dword
7639
Selected Mechanical Value
 
dword
550
Defect Count Reject A
 
dword
678
Defect Count Reject B
 
dword
1062
Length Counts
 
dword
1126
Width Counts
 
dword
1190
Area Counts
 
dword
1999
Configuration Length Counts
 
dword
2032
Configuration Width Counts
 
dword
2065
Configuration Area Counts
 
dword
99
Accept Total Area
 
dword
101
Accept Total Length
 
dword
103
Accept Total Width
 
dword
105
Accept Defects
 
dword
2999
Ejector A Count
 
dword
3999
Ejector B Count
 
dword

Note: Products and companies mentioned here are used only for definition and identification purposes and can be trademarks and/or registered trademarks of the respective companies.