GE EPM 5100, EPM 5300 MODBUS registers: read online
Connect GE to the computer through a USB-to-serial or RS485 adapter and read its registers in your browser: click "Read register values online" under the model (Chrome or Edge, nothing to install). The tables below list the MODBUS offset, unit, data type and scale of every register shown.
For logging 24/7 into a database, CSV files or Excel, use the Advanced Serial Data Logger (for MODBUS RTU) or Advanced TCP/IP Data Logger (for MODBUS TCP): they poll the complete map of every model on this page and provide continuous GE modbus logging and log.
Registers in the map: 94 (the first 79 are listed below; the browser reader and the data loggers use the complete map). function 1 (coil status). function 3 (holding registers). function 4 (input registers). byte order big-endian. data types: integer, single, smallint, word.
MODBUS offset
Description
Units
Data type
Scale
0
Clear power demand
W
word
1
Initialize meter
word
2
Clear energy (var-hour)
word
3
Clear meter errors
word
6
Firmware revision
single
formula
8
COC software revision
single
formula
4
Serial number
integer
3000
Hour
smallint
3001
Minute
smallint
3002
Seconds
smallint
3005
Pulse value interval time for pulse KYZ output 1
single
3007
Pulse value interval time for pulse KYZ output 2
single
3009
Pulse units for KYZ output 1
word
3010
Pulse units for KYZ output 2
word
3011
Programming flags
word
3013
Demand interval length (in minutes)
smallint
3014
Number of sub-intervals
smallint
3015
Display scroll time
smallint
3016
Meter configuration
word
3017
Potential transformer ratio
single
3019
Current transformer ratio
single
3021
Energy display format
word
3022
Demand display format
word
3023
Voltage display format
word
3024
Amps display format
word
3025
Energy display scale (kWh, MWh)
word
3026
Demand display scale (W, kW, MW)
word
3027
Voltage display scale (V, kV)
word
3028
Amps display scale (A, kA)
word
1000
Number of pending event messages
smallint
1002
kVA max, total of all phases
kVA
single
1004
kW max, total of all phases
kW
single
1006
Kvar lag max, total of all phases
kvar
single
1008
Kvar lead max, total of all phases
kvar
single
1010
Current max phase A
A
single
1012
Current max phase B
A
single
1014
Current max phase C
A
single
1016
Kvarh lag, total of all phases
kvar
single
1018
Kvarh lead, total of all phases
kvar
single
1020
kWh, total of all phases
kW
single
1022
kQh, total of all phases
single
1024
kVAh, total of all phases
kVA
single
1026
Average power factor since last reset, all phases
single
1028
Power factor, total of all phases, at maximum
kVA
single
1030
Apparent power demand , total of all phases
kVA
single
1032
Real power demand total of all phases
kW
single
1034
Reactive power demand (kvar lag), total of all phases
kvar
single
1036
Reactive power demand (kvar lead), total of all phases
kvar
single
1038
Current demand, phase A
A
single
1040
Current demand, phase B
A
single
1042
Current demand, phase C
A
single
1044
Power factor, all phases (over last demand interval)
single
1046
Real power , phase A
kW
single
1048
Real power , phase B
kW
single
1050
Real power , phase C
kW
single
1052
Reactive power , phase A
kvar
single
1054
Reactive power , phase B
kvar
single
1056
Reactive power , phase C
kvar
single
1058
Apparent power , phase A
kVA
single
1060
Apparent power , phase B
kVA
single
1062
Apparent power , phase C
kVA
single
1064
Power factor, phase A
single
1066
Power factor, phase B
single
1068
Power factor, phase C
single
1070
Apparent power , total of all phases
kVA
single
1072
Real power , total of all phases
kW
single
1074
Reactive power , total of all phases
kvar
single
1076
L-N voltage, phase A-N
V
single
1078
L-N voltage, phase B-N
V
single
1080
L-N voltage, phase C-N
V
single
1082
L-L voltage, phase A-B
V
single
1084
L-L voltage, phase B-C
V
single
1086
L-L voltage, phase C-A
V
single
1088
Total power factor of all phases
single
1090
Real power , total of all phases at maximum kVA
kW
single
1092
Current, phase A
A
single
1094
Current, phase B
A
single
1096
Current, phase C
A
single
1098
Neutral current
A
single
This is not the complete map: 79 of 94 registers are listed above. Click "Read register values online" to read any register of your device in the browser, or download the program to log the complete map.
Registers in the map: 132 (the first 50 are listed below; the browser reader and the data loggers use the complete map). function 3 (holding registers). byte order big-endian. data types: word.
MODBUS offset
Description
Units
Data type
Scale
278
Volt an, Instant
word
317
Volt an, Average
word
356
Volt an, Max
word
395
Volt an, Min
word
279
Volt bn, Instant
word
318
Volt bn, Average
word
357
Volt bn, Max
word
396
Volt bn, Min
word
280
Volt cn, Instant
word
319
Volt cn, Average
word
358
Volt cn, Max
word
397
Volt cn, Min
word
281
Volt ab, Instant
word
320
Volt ab, Average
word
359
Volt ab, Max
word
398
Volt ab, Min
word
282
Volt bc, Instant
word
321
Volt bc, Average
word
360
Volt bc, Max
word
399
Volt bc, Min
word
283
Volt ca, Instant
word
322
Volt ca, Average
word
361
Volt ca, Max
word
400
Volt ca, Min
word
284
Amp A, Instant
word
323
Amp A, Average
word
362
Amp A, Max
word
401
Amp A, Min
word
285
Amp B, Instant
word
324
Amp B, Average
word
363
Amp B, Max
word
402
Amp B, Min
word
286
Amp C, Instant
word
325
Amp C, Average
word
364
Amp C, Max
word
403
Amp C, Min
word
287
Amp N, Instant
word
326
Amp N, Average
word
365
Amp N, Max
word
404
Amp N, Min
word
288
Watt, Instant
word
327
Watt, Average
word
366
Watt, Max
word
405
Watt, Min
word
289
Var, Instant
word
328
Var, Average
word
367
Var, Max
word
406
Var, Min
word
290
Va, Instant
word
329
Va, Average
word
This is not the complete map: 50 of 132 registers are listed above. Click "Read register values online" to read any register of your device in the browser, or download the program to log the complete map.
5555 is used when passwords are disabled in the programmable settings
COM1 setup register
30025 (0x7548)
COM1 protocol field
ppp, 1 = Modbus RTU, 2 = Modbus ASCII, 3 = DNP
COM1 baud rate field
bbb, 1 = 9600, 2 = 19200, 4 = 38400, 6 = 57600
COM1 reply delay field
dddd, reply delay x 50 ms
COM2 setup register
30026
COM2 address register
30027, range 1-247
Word order
high order half in the lower addressed register
Undefined registers
read as 0
Registers in the map: 102 (the first 50 are listed below; the browser reader and the data loggers use the complete map). function 3 (holding registers). byte order big-endian. data types: dword, integer, single, smallint, string(16), string(4), word.
MODBUS offset
Description
Units
Data type
Scale
17
Firmware version
string(4)
19
Map version
word
21
ASIC version
word
0
Meter name
string(16)
8
Meter serial number
string(16)
16
Meter type
word
20
Meter configuration
word
39
GE part number
string(16)
899
Watts, 3-Ph total
single
901
VARs, 3-Ph total
single
903
VAs, 3-Ph total
single
999
Volts A-N
single
1001
Volts B-N
single
1003
Volts C-N
single
1005
Volts A-B
single
1007
Volts B-C
single
1009
Volts C-A
single
1011
Amps A
single
1013
Amps B
single
1015
Amps C
single
1017
Watts, 3-Ph total
single
1019
VARs, 3-Ph total
single
1021
VAs, 3-Ph total
single
1023
Power factor, 3-Phtotal
single
1025
Frequency
single
1027
Neutral current
single
1099
W-hours, received
integer
1101
W-hours, delivered
integer
1103
W-hours, net
integer
1105
W-hours, total
integer
1107
VAR-hours, positive
integer
1109
VAR-hours, negative
integer
1111
VAR-hours, net
integer
1113
VAR-hours, total
integer
1115
VA-hours, total
integer
1999
Amps a, average
single
2001
Amps b, average
single
2003
Amps c, average
single
2005
Positive watts, 3-Ph,Average
single
2007
Positive VARs, 3-Ph,Average
single
2009
Negative watts, 3-Ph,Average
single
2013
VAs, 3-Ph, average
single
2015
Positive PF, 3-Ph,Average
single
2017
Negative PF, 3-PF,Average
single
2999
Volts A-N, minimum
single
3001
Volts B-N, minimum
single
3003
Volts C-N, minimum
single
3005
Volts A-B, minimum
single
3999
Volts A-N, %THD
word
4000
Volts B-N, %THD
word
This is not the complete map: 50 of 102 registers are listed above. Click "Read register values online" to read any register of your device in the browser, or download the program to log the complete map.
Registers in the map: 150 (the first 50 are listed below; the browser reader and the data loggers use the complete map). function 3 (holding registers). byte order big-endian. data types: integer, single, smallint, string(16), string(4), string(8), word.
MODBUS offset
Description
Units
Data type
Scale
17
Firmware version
string(4)
19
Map version
word
21
ASIC version
word
22
Boot Firmware Version
string(4)
0
Meter name
string(16)
8
Meter SerialNumber
string(16)
16
Meter type
word
20
MeterConfiguration
word
24
Option slot 1Usage
word
25
Option slot 2Usage
word
26
Meter type name
string(8)
278
Integer readings block occupies these registers, see below
word
279
Volts B-N
word
280
Volts C-N
word
281
Volts A-B
word
282
Volts B-C
word
283
Volts C-A
word
284
Amps A
word
285
Amps B
word
286
Amps C
word
289
VARs, 3-Ph total
smallint
290
VAs, 3-Ph total
word
291
Power factor, 3-Phtotal
smallint
294
Watts, phase B
smallint
295
Watts, phase C
smallint
296
VARs, phase A
smallint
297
VARs, phase B
smallint
298
VARs, phase C
smallint
299
VAs, phase A
word
300
VAs, phase B
word
303
Power Factor,Phase B
smallint
304
Power Factor,Phase C
smallint
999
Volts A-N
single
1001
Volts B-N
single
1003
Volts C-N
single
1005
Volts A-B
single
1007
Volts B-C
single
1009
Volts C-A
single
1011
Amps A
single
1013
Amps B
single
1015
Amps C
single
1017
Watts, 3-Ph total
single
1019
VARs, 3-Ph total
single
1021
VAs, 3-Ph total
single
1023
Power factor, 3-Phtotal
single
1025
Frequency
single
1027
Neutral current
single
1029
Watts, phase A
single
1031
Watts, phase B
single
1033
Watts, phase C
single
This is not the complete map: 50 of 150 registers are listed above. Click "Read register values online" to read any register of your device in the browser, or download the program to log the complete map.